Loading...
HomeMy WebLinkAboutReview Checklist /--z � - � � �-I�,� .� ✓,'�-,G"��,� TOWN OF YARMOUTH _c,G����j��� �'��l�i''�1�� SEWAGE PLAN REVIEW CHECKLIST I Location: A.M. `J� � Lot ��- Zone of Contribution: In Out creage � Commercial: ResidentiaL• � Street: � Village: , Floor Plan: #Bedrooms: � � Owner: � /1l%G��u`/� Insta.11er: Address: Phone: �" 7'7� � 7 � Phone: � ,�;,�, " C�L�;��c:�/ t�c,�c_ Builder: Engineer: � � ^ Address: Phone: Phone: - �-iJ/` G1 ' �/��/6�/ ., �` �. N/A YES NO 1.Required#of co ies received 2.Date of soils exam and ercolation test not older than 2 ears 3.4-5 ft of naturall occurrin ervious material, above water table 4.Founda.tion 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic com onents Var.: ✓� 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, d�k Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L�' : 9.Leaching minimum 100 ft from wetlands Var.: , 10.Lea.chin minimum 150 ft from drinkin welU25 ft irrigation well Var.: 11.Tank/leachin minimum 10 ft from properry line Var.: 12. S stem meets all other setback r uirements Var.: 13.Uses ad'ustment for maximum high groundwater Var.: � 14.Leachin set 4-5 ft above adj.water or bottom test h�Var.: 15. System not in to or subsoil(A,B horizons)or 'remova 16.Pro osed contours are suitable 17. S stem meets slo e r uirements-min. 1/8", '/4" referred 18. System meets breakout re uirements PVC liner: � � all: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 d for parcel �/ ^ 21.No garbage disposal L1 22. S stem ad uatel sized for its intended use �---� 23.Minimum 6"stone or compacted below tank and dbox ' 24.Manhole covers within 6"of grade, um chamber cover to grade 25.Ins ection ort on lastic chambers/leach field ' 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pum system-2"line,wee hole,check valve,tee in dbox, um size 28. S tic tank/ um chamber to be factory waterproofed � - 29.Vent provided if leaching below 3 feet,under driveway/ arking 30.Buoyanc calculations for tank/ ump chamber �.� 31.En ' eer to ins ect and cert' soils: wall: commercial: - 32.En ' eer/Registered Sanitarian and Land Surveyor sta.m s/signature : , 33.H-201oading is subject to vehicular traffic, groundwater 34.Title V A lication and ermit fee, installer si ture 35.Foundation footin min. 2 feet above adjusted ground water for new house ' 36.Deed Restriction r uired max. #bedrooms: . flow: �- d ': 37.Check area lots for groundwater/Label oundwater in Assessor's Ma Plan reviewed by: �o3io3