Loading...
HomeMy WebLinkAbout94 Cranberry Lane Sewage Disp.SOIL TEST PIT DATA: TEST PIT .-#1_ GRD. EL. 91.0 EST. HIGH GW. 77.0 FIBRIC E LOAMY SAND 2.5Y 5/2 B LOAMY SAND 10YR 5/8 C-1 LOAMY SAND 2.5Y 6/6 LOAMY SAND 2.5Y 6 3 EL = 85.0 94- C-3 LOAMY FINE SAND 2.5Y 6/6 NO G.WATER EL = 77.0 AUGUST 25, 2005 DATUM: VERTICAL DATUM: ASSUMED BENCH MARK SET: HYDRANT TAG BOLT #336 ELEVATION 88.16 PROFILE: NOT TO SCALE - CONCRETE COVERS TO WITHIN EL.= 91.5 6" OF FINISHED GRADE. SEPTIC TANK INVERT ELEVATIONS: 5 OUTLETL DIST. BOX INDICATES T ESTIMATED SEASONAL HIGH GROUND WATER INDICATES _ V OBSERVED GROUND WATER Dog DN INDICATES DN PERC. TEST ®INDICATES UNSUITABLE MATERIAL FIRST PIPE LENGTH TO BE SET LEVEL FOR MIN. 2' FINISH GRADE EL.=89.5-90.0 4' PVC SCH 40� LEACHING CHAMBER 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I=G H 7.5' SEPARATION ` EST. HIGH GROUNDWATER J TOP OF FOUNDATION DATE: A 8-25-05 6" TEST BY: 4" INVERT AT SEPTIC TANK (IN) RON CADALLAC C WITNESSED BY: 9„ AMY VON HONE 4" INVERT AT DIST. BOX (IN) PERC. RATE: E 8 MIN./INCH 30" SOIL EVALUATOR RON CADALLAC R-40 SOIL CLASS: 4" INVERT AT BEGINNING 1 60" OF LEACHING CHAMBER 86.50 L. T. A. R. ELEVATION AT BOTTOM 0.66 G.P.D./SO.FT. 72" OF LEACHING CHAMBER AUGUST 25, 2005 DATUM: VERTICAL DATUM: ASSUMED BENCH MARK SET: HYDRANT TAG BOLT #336 ELEVATION 88.16 PROFILE: NOT TO SCALE - CONCRETE COVERS TO WITHIN EL.= 91.5 6" OF FINISHED GRADE. SEPTIC TANK INVERT ELEVATIONS: 5 OUTLETL DIST. BOX INDICATES T ESTIMATED SEASONAL HIGH GROUND WATER INDICATES _ V OBSERVED GROUND WATER Dog DN INDICATES DN PERC. TEST ®INDICATES UNSUITABLE MATERIAL FIRST PIPE LENGTH TO BE SET LEVEL FOR MIN. 2' FINISH GRADE EL.=89.5-90.0 4' PVC SCH 40� LEACHING CHAMBER 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I=G H 7.5' SEPARATION ` EST. HIGH GROUNDWATER J TOP OF FOUNDATION 93.00 A 4" INVERT AT BUILDING 88.00 B 4" INVERT AT SEPTIC TANK (IN) 87.55 C 4" INVERT AT SEPTIC TANK (OUT) 87.30 D 4" INVERT AT DIST. BOX (IN) 86.80 E 4" INVERT AT DIST. BOX (OUT) 86.63 F INVERTS AT LEACHING FACILITY: R-40 •• 4" INVERT AT BEGINNING FRONT 30' ot OF LEACHING CHAMBER 86.50 G BREAKOUT 87.0 ELEVATION AT BOTTOM REAR 20' DEPTH OF LEACHING CHAMBER 84.50 H NO OBSERVED GROUNDWATER PROPOSED LOT COVERAGE: 1,518± S.F. (67.) BOTTOM OF HOLE 77.0 J VARIANCES REQUESTED: NONE FLOOR PLANS: SEE ATTACHED SEPTIC TANK DETAIL: 1,500 GALLON NOT TO SCALE NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, REINFORCED CONCRETE. SCHEO. 40 PVC OR CAST -IN-PLACE CONCRETE. 2. SEPTIC TANK TO WITHSTAND H-10 LOADING TEES TO BE CENTERED UNDER MANHOLE COVER. UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS, WHEREIN H-20 LOADING SHALL APPLY. 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 2-24" DIA CONCRETE MANHOLES 4. FILL ALL UNUSED KNOCKOUTS WITH W/ METAL HANDLES BROUGHT MORTAR. TO 6" OF FINISH GRADE TEE TO BE UNDER C SRN M.H. OPENING 10'-6" RAISE M.H W/_ SEWER BRICK e- • . e .: 10'-0' & MORTAR a =e I NORMAL WATER LEVEL 12-1 rFmL 3' PRECAST SEPTIC TANK e f 10' 14" e INLETIT TEE O O C- 5'2- 4' -s" 4'-0" MIN. •m eao ON 5'-8" � LIQUID DEPTH (au"T o .e N ���: r. ••i .!'.C.' e: -�.. ems:: -. ..e: a _. ee: �.P: DISTRIBUTION BOX DETAIL: 1 �-3' ' w I 4' T 5'-8" 15 1/2" 1 PLAN VIEW c BOTTOM ON LEVEL STABLE BASE �$ 6" MIN. 3/4' To 1 1/2" STONE CROSS-SECTION VIEW LOCUS PLAN: NO SCALE W. GREAT WESTERN R❑AD 6 DRIFTW❑❑D LN, LOCUS GRADE NOT TO SCALE NO. OF OUTLETS: 5 - - 1-- 2' WALLS NOTES: 4••+.v:•a..+,v:•v....: v.:•' 2' 1. DIST. BOX TO WITHSTAND H-10 LOADING TUNLESS UNDER TRAVELED WAYS AVEMENT, DRIVES OR T WHEREIN H-20 LOADING ti T15" SHALL APPLY. i,5' OUTLETS 8" 1 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR �e ee o • ee a oea oe+ T IN PUMPED SYSTEM. ovA L 2' 3. FIRST TWO FEET OF PIPE OUT OF DIST. 30TTOM ON LEVEL 'STABLE BASE 6' MIN. 3/4" TO BOX TO BE LAID LEVEL. CROSS-SECTION 1 C USHED 4. ALL PIPE CONNECTIONS AND CONCRETE STOONENE BASE CONSTRUCTION SHALL BE WATERTIGHT. 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 30 1/2" ffil PRECAST DIST. BOX 7 1/2 PLAN VIEW BENCHMARK HYDRANT TAG BOLT LEACHING DETAIL: NOT TO SCALE 4" PVC 1 1 25.5' - PIPE LOCUS INFORMATION MAXIMUM,12"MINIMUM CURRENT OWNER: FRANCES MASON ° ° TITLE REFERENCE: DEED BOOK 20578, PAGE 178 0°0 PLAN REFERENCE: PLAN BOOK 120, PAGE 119 O ASSESSORS MAP: 118 c o 0 0 PARCEL: 78 ZONING DISTRICT: R-40 •• SETBACKS: FRONT 30' ot C� SIDE 20' UNSUITABLE REAR 20' DEPTH MINIMUM LOT SIZE: 40,000 S.F. EXISTING LOT AREA: 25,151± S.F. PROPOSED LOT COVERAGE: 1,518± S.F. (67.) OVERLAY DISTRICT- APD NITROGEN SENSITIVE ZONE: NOT A ZONE II FEMA FLOOD ZONE DISTRICT: "C" 7/2/1992 PANEL #250015 0002 D BENCHMARK HYDRANT TAG BOLT LEACHING DETAIL: NOT TO SCALE 4" PVC 1 1 25.5' - PIPE 29.5 PLAN VIEW - LEACHING CHAMBER LOAM & SEED DISTURBED AREAS 3 ...........aiii MAX. COMPACTED FI L 36" MAXIMUM,12"MINIMUM 0 ° ° 0 O l� 0°0 3" LAYER O O O 008 c o 0 0 0 Q 0 ASTONE REMOVE 10 •• • �. Ctj0 ot C� 0 UNSUITABLE DEPTH C�� 0 C� C� 29.5 PLAN VIEW - LEACHING CHAMBER LOAM & SEED DISTURBED AREAS 3 ...........aiii MAX. COMPACTED FI L 36" MAXIMUM,12"MINIMUM ° ° 0 O l� 0°0 3" LAYER 34EFFEC. T 008 c o 0 0 0 Q 0 ASTONE REMOVE Ctj0 C� C� C� C� C� 0 UNSUITABLE DEPTH C�� 0 C� C� C� O MATERIAL FOR 5' ALL AROUND 1 0 0 0 056" 0 3/4" - 1 1/2 - /2"WASHED WASHED STONE 12'-10" 22'-10" CROSS-SECTION OF CHAMBER DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT110G.P.B./D 330 G.P.D. REQUIRED SEPTIC TANK: 330 X 200% - 660 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <2 MIN./ INCH LONG TERM APPL. RATE 0,66 G.P.D/S.F. 330 GPD r 0,66 GPD/SF = 500 S.F. SIZE OF LEACHING FACILITY PROVIDED: USE 500 GALLON LEACHING CHAMBERS(3 UNITS) 12',83X2'X29,5' SIDEWALL = 2(12.83'+29.5') X 2' = 169,3 BOTTOM = 12.83' X 29,5' = 378A 547S,F, 547 S.F x 0,66 GPD/SF = 361GPD `,,, I ELEVATION 88.16 /~�C01� ESE\B�?t1N0. FOjND Bc\HfiLb`\�\\ IOIa (; / _/ I \ \\\\ \ O R� OCT L� LOT 17 �- o w ON/ / \ \ `� \\ _\\\ EXISTING SEPTIC COMPONENTS `\\ TO BE PUMPED, CRUSHED & ON�y / I I \ \�STjNG \ \� `\ ` \ \ \ \\ \ REMOVED FROM SITE IN f / / W oRT� \ \ \ \6� \\; \ ACCORDANCE WITH TITLE 5. / / l �/ / ! r / I .,�ec,T� p`�.��wq y ,` ' ted" �� •�� `�\ � ���w // /f7 l e�k!v ���-���'�� 'rte l °�� l / CT \ \ r c CRAIG A. u. l �i _ r r ` / 1 rI I..D / aY t:_ 2aa3sa .trnt °° .,_ \ \ \\ \\ 9 ` / EXISTING / 10/y / f MOBILE HOME-- \ \ / f / \ 45.4 /( / •.��. - 1 \ 159.3\T16 UTfpTNG ETe� 145.y f �W 1 i 1 not.t F:e^:t'a Department E /92.2 CID PROPOSED FOUND TIPPED 3 BEDROOM ��� 91.2' DWEWNG _ PROPOSED T.O.F. 93.0 TO ' WORK MUST Lr0 FO ALL TOWN� - � = . - -•- / i �� LIMITS OF BYLAWS AND G TIM y �``4' 25.5' a /� EXCAVATION SZ3, � �/ � co 5EAND 6ES PROPOSED 00 _\ // nDi `�1'ARMOUTH WATER DEPT D BOK ! L E " " PROPOSED 12.83'x29.5' 22, 8 / ! �' f 1 LEACHING S.A.S. oo,` ( OF PROPOSED `\ 24j29 ` -- 2-3.T'---�Q- 1 1 � MARK D. �c PLAN VIEW 1500 GALLON \ LOT 15 SEPTIC TANK \ TP#1 f q CIVIL EXISTING No. 45937 \ � f i SCALE: 1" = 20 FEET DWELLING TO BE REMOVED ? IST \ PROPOSED 0 1n an en CT -\ IYLYP UM-LUNU 64'-2"x23'-8" 4&/z 31oc REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A #4 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FlLL, UP TO 457 BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE 14 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 107-100% MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 0%-207. MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 07-5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS, THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THS ST4RT OF C.ONSTUi.ilCar. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONFIRM LOCATION & NUMBER OF INVERTS. INGINEER IS TO BE NOTIFIED OF iELD CHANGES THAT MAY BE J" 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 508 778 8919 'ROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR/UPGRADE #94 CRANBERRY LANE SOUTH YARMOUTH MASSACHUSETTS PREPARED FOR: CRAFTSBURY COMPANY, INC. LADD KAUTZ 845 MAIN STREET, ROUTE 28 SOUTH YARMOUTH, MA 02664 (508) 760-0500 DATE_ AUGUST 23, 2006 COMP./DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D. CAZZOLO / J. M,C, TIN FILE NO. 915„-SEP.DwG - -S DWG NO. 5333-02'' JOB N0. 4-9156.001 'HEET 1 OF 1