HomeMy WebLinkAbout94 Cranberry Lane Sewage DisposalSOIL TEST PIT DATA: TEST PIT -#1L GRD. EL. 91.0 EST. HIGH GW. 77.0 ii i FIBRIC LOAMY SAND 2.5Y 5/2 LOAMYB SAND IOYR 5/8 C-1 LOAMY SAND 2.5Y 6/6 LOAMY SAND 2.5Y 6 3 EL = 85.0 92'1- C -3 2"C-3 LOAMY FINE SAND 2.5Y 6/6 NO G.WATER EL = 77.0 AUGUST 25, 2005 DATUM: VERTICAL DATUM: ASSUMED BENCH MARK SET: HYDRANT TAG BOLT #336 ELEVATION 88.16 PROFILE: NOT TO SCALE EL.= A TOP FOUNDATION CONCRETE COVERS TO WITHIN EL. -91.5 6" OF FINISHED GRADE. SEPTIC TANK INVERT ELEVATIONS: 5 OUTLET DIST. BOX INDICATES _L ESTIMATED SEASONAL HIGH GROUND WATER INDICATES OBSERVED GROUND WATER INDICATES PERC. TEST INDICATES ® UNSUITABLE MATERIAL FIRST PIPE LENGTH TO BE SET LEVEL FOR MIN. 2' FINISH GRADE EL.=89.5-90. 4" PVC SCH 40 /-- 7qqgAz 0 0 0 0 7.5' SEPARATION EST. HIGH GROUNDWATER J TOP OF FOUNDATION DATE: A 8-25-05 6" TEST BY: 4" INVERT AT SEPTIC TANK (IN) RON CADALLAC C WITNESSED BY: 9 AMY VON HONE 4" INVERT AT DIST. BOX (IN) PERC. RATE: E 8 MIN./INCH 30" SOIL EVALUATOR INVERTS AT LEACHING FACILITY: RON CADALLAC BASE SOIL CLASS: �UNSUITABLE 1 60" 86.50 G BREAKOUT 87.0 L.T.A.R. 0.66 G.P.D./SQ.FT. 72" 84.50 AUGUST 25, 2005 DATUM: VERTICAL DATUM: ASSUMED BENCH MARK SET: HYDRANT TAG BOLT #336 ELEVATION 88.16 PROFILE: NOT TO SCALE EL.= A TOP FOUNDATION CONCRETE COVERS TO WITHIN EL. -91.5 6" OF FINISHED GRADE. SEPTIC TANK INVERT ELEVATIONS: 5 OUTLET DIST. BOX INDICATES _L ESTIMATED SEASONAL HIGH GROUND WATER INDICATES OBSERVED GROUND WATER INDICATES PERC. TEST INDICATES ® UNSUITABLE MATERIAL FIRST PIPE LENGTH TO BE SET LEVEL FOR MIN. 2' FINISH GRADE EL.=89.5-90. 4" PVC SCH 40 /-- 7qqgAz 0 0 0 0 7.5' SEPARATION EST. HIGH GROUNDWATER J TOP OF FOUNDATION 93.00 A 4" INVERT AT BUILDING 88.00 B 4" INVERT AT SEPTIC TANK (IN) 87.55 C 4" INVERT AT SEPTIC TANK (OUT) 87.30 D 4" INVERT AT DIST. BOX (IN) 86.80 E 4" INVERT AT DIST. BOX (OUT) 86.63 F INVERTS AT LEACHING FACILITY: STONE BASE 4" INVERT AT BEGINNING �UNSUITABLE OF LEACHING CHAMBER 86.50 G BREAKOUT 87.0 ELEVATION AT BOTTOM OF LEACHING CHAMBER 84.50 H NO OBSERVED GROUNDWATER 34" BOTTOM OF HOLE 77.0 J VARIANCES REQUESTED: NONE FLOOR PLANS: SEE ATTACHED SEPTIC TANK DETAIL: 1,500 GALLON NOT TO SCALE NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, REINFORCED CONCRETE. SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE. 2. SEPTIC TANK TO WITHSTAND H-10 LOADING TEES TO BE CENTERED UNDER MANHOLE COVER. UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS, WHEREIN H-20 LOADING SHALL APPLY. 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 2-24" DIA CONCRETE MANHOLES 4. FILL ALL UNUSED KNOCKOUTS WITH W/ METAL HANDLES BROUGHT MORTAR. TO 6" OF FINISH GRADE TEE TO BE UNDER F12* MIN. M.H. OPENING -, nnuco 10'-6" RAISE M,H W L SEWER BRICK 10'-0" & MORTAR + -NOR __TL 3" PRECAST SEPTIC TANK a 10" e INLET TEE DO(D5'-2- 4 _g• e 4'-0" MIN. C 5-8- 5 Z LIQUID DEPTH N :y 1 14" eBD% (G owma j PLAN VIEW t ' BOTTOM ON LEVEL STABLE BASE 6" MIN. 3/4" TO 4'--,r4-W 1 1/2" STONE CROSS-SECTION VIEW LOCUS PLAN: NO SCALE DISTRIBUTION BOX DETAIL: NOT TO SCALE NO. OF OUTLETS: 5 FINISHED GRADE REMOVABLE COVER r- 3- 4' 5'-1" 5'-8" 15 1/2" 1 IOTTOM ON LEVEL STABLE BASE CROSS-SECTION 30 1 PRECAST DIST. Box 71/2 PLAN VIEW I- 2' WALLS NOT TO IT T - 25.5' - 1 PIPE 0 ° tbaa T q, L 2" " MIN. 6 3//4" TO 1 1/2" C1IUSHED STONE BASE NOTES: 1. DIST. BOX TO WITHSTAND H-10 LOADING UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING SHALLAPPLY. 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR IN PUMPED SYSTEM. 3. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL. 4. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. LEACHING DETAIL: NOT TO SCALE 4" PVC - 25.5' - PIPE 0 ° 17777 0 00Oo°OO°77" 29.5 0 ° 3 UNITSoc°0 o°° 0 ° 17777 0 DISTURBED AREAS °o 00 o° 1717777777777777777777 ••• �UNSUITABLE ,MAXI MAXIMUM,12"MINIMUM o ING DRYWELLS ° 34" ASTONE o 0°00 0 000 °0 0 0° °o °°0 0000 00 000 00 0 0 00 00000 0° 0 ° o ° o DRIFTW❑❑D LN, LOCUS INFORMATION DESIGN CRITERIA.: DESIGN FLOW: ci CURRENT OWNER: FRANCES MASON 3 BEDROOMS AT110G.P.B./D 330 G.P.D. TITLE REFERENCE: DEED BOOK 20578, PAGE 178 REQUIRED SEPTIC TANK: N 2 PLAN REFERENCE: PLAN BOOK 120, PAGE 119 330 X 200% = 660 GAL. 2 ASSESSORS MAP: 118 SEPTIC TANK PROVIDED: = 1500 GAL. PARCEL: 78 SIZE OF LEACHING FACILITY REQUIRED I= Q LOCUS ZONING DISTRICT: R-40 Q J SETBACKS: FRONT 30 DESIGN PERC. RATE: <2 MIN./ INCH 2 SIDE 20' LONG TERM APPL. RATE 0,66 G.P.D/S.F. D REAR 20' MINIMUM LOT SIZE: 40,000 S.F. 330 GPD + 0,66 GPD/SF = 500 S,F, EXISTING LOT AREA: 25,151t S.F. SIZE OF LEACHING FACILITY PROVIDED -)V PROPOSED LOT COVERAGE: 1,5181 S.F. (67.) W. GREAT WESTERN ROAD OVERLAY DISTRICT- APD USE 500 GALLON NITROGEN SENSITIVE LEACHING CHAMBERS(3 UNITS) 12',83X2'X29,5' 6 ZONE: NOT A ZONE II SIDEWALL = 2(12,133'+29,51) X 2' = 169.3 FEMA FLOOD BOTTOM 12,83' X 295' = 378,4 ZONE DISTRICT: "C" 7/2/1992 547S,F, PANEL #250015 0002 D 547 S.F x 0.66 GPD/SF = 361GPD 3 S BENCHMARK HYDRANT TAG BOLT ELEVATION 88.16 CO*&\HELb\ E \ ` FO /4.4j LOT 17 EXISTING SEPTIC COMPONENTS TO BE PUMPED, CRUSHED & ;wvc REMOVED FROM SITE IN ACCORDANCE WITH TITLE 5. eo0 i l _Qj 93-- / l / l/ 3 I l t f4? i } / \ II � � �/ / � � �) �• � s4 8g• \ � � � \ ,,,�.,, uyt' � ,. 11 l I ro / v � EXISTINIG % (t) / /, MOBILE HOME-' II 7^ / / \ X45.4' y -145.I jw 1 1 I ���� LOT 16 y 92.2 CONCRETE BOUND Q �. \ f 5 =� / / rn ,�•w 111 } i a FOUND TIPPED D �� :' / Np PROPOSED 3 BEDROOM 91.2 DWEWNG \ _ T.O.F. 93.0 \\ N /i / / PROPOSED LIMITS OF �.�_ �` �� \ j �''� 64 / \ 5.5'°°' i I EXCAVATION S�3 3 SEE NOTES PROPOSED �0,1O"F "�� _ __ ` //co m / 5 AND 6 "D" BOX ` 1 I 1 PROPOSED \\ \ '/ ! I l 1 f ) 12.83'x29.5' 2$.8' coo l t LEACHING S.A.S. �r \ �// 0)• 1 I l�tNOFW PROPOSED ` 24 i 2Ss 1500 GALLON \\ X29' _ -3:1--_ j I c PLAN VIEW LOT 15 SEP11C TANKEXISTING ` \ TP#1 / !I \ I c SCALE: 1' = 20 FEET DWELLING TO BE REMOVED c�Q / 1 ,sTE \ PROPOSED - 0 10 20 40 FT. \ NEW DWELLING 64'-2"x23'-8" ` REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6, REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A 04 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 457 BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 107,100% MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 07.-207 MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 07,5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO 1NE STA.^T... OF B. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION, CONFIRM LOCATION & NUMBER OF INVERTS. 10. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. �✓ `� �... 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 5087788 19 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR/UPGRADE #94 CRANBERRY LANE SOUTH YARMOUTH MASSACHUSETTS PREPARED FOR: CRAFTSBURY COMPANY, INC. LADD KAUTZ 845 MAIN STREET, ROUTE 28 SOUTH YARMOUTH, MA 02664 (508) 760-0500 DATE: AUGUST 23, 2006 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D. GAZZOLO / J. MCCARTIN FILE NO. 9156-SEP.DWG DWG N0, 5383-02 JOB NO.4-9156.00 SHEET 1 OF 1 29.5 17777 LOAM & SEED DISTURBED AREAS 3' MAX. 1717777777777777777777 ••• �UNSUITABLE ,MAXI MAXIMUM,12"MINIMUM 34" ASTONE EFFEC. 24"Ek Cb REMOVE" t 0 MATERIAL •.DEPTH ALL AROUND 0 ' • STONE • '•-SECTIONOF DRIFTW❑❑D LN, LOCUS INFORMATION DESIGN CRITERIA.: DESIGN FLOW: ci CURRENT OWNER: FRANCES MASON 3 BEDROOMS AT110G.P.B./D 330 G.P.D. TITLE REFERENCE: DEED BOOK 20578, PAGE 178 REQUIRED SEPTIC TANK: N 2 PLAN REFERENCE: PLAN BOOK 120, PAGE 119 330 X 200% = 660 GAL. 2 ASSESSORS MAP: 118 SEPTIC TANK PROVIDED: = 1500 GAL. PARCEL: 78 SIZE OF LEACHING FACILITY REQUIRED I= Q LOCUS ZONING DISTRICT: R-40 Q J SETBACKS: FRONT 30 DESIGN PERC. RATE: <2 MIN./ INCH 2 SIDE 20' LONG TERM APPL. RATE 0,66 G.P.D/S.F. D REAR 20' MINIMUM LOT SIZE: 40,000 S.F. 330 GPD + 0,66 GPD/SF = 500 S,F, EXISTING LOT AREA: 25,151t S.F. SIZE OF LEACHING FACILITY PROVIDED -)V PROPOSED LOT COVERAGE: 1,5181 S.F. (67.) W. GREAT WESTERN ROAD OVERLAY DISTRICT- APD USE 500 GALLON NITROGEN SENSITIVE LEACHING CHAMBERS(3 UNITS) 12',83X2'X29,5' 6 ZONE: NOT A ZONE II SIDEWALL = 2(12,133'+29,51) X 2' = 169.3 FEMA FLOOD BOTTOM 12,83' X 295' = 378,4 ZONE DISTRICT: "C" 7/2/1992 547S,F, PANEL #250015 0002 D 547 S.F x 0.66 GPD/SF = 361GPD 3 S BENCHMARK HYDRANT TAG BOLT ELEVATION 88.16 CO*&\HELb\ E \ ` FO /4.4j LOT 17 EXISTING SEPTIC COMPONENTS TO BE PUMPED, CRUSHED & ;wvc REMOVED FROM SITE IN ACCORDANCE WITH TITLE 5. eo0 i l _Qj 93-- / l / l/ 3 I l t f4? i } / \ II � � �/ / � � �) �• � s4 8g• \ � � � \ ,,,�.,, uyt' � ,. 11 l I ro / v � EXISTINIG % (t) / /, MOBILE HOME-' II 7^ / / \ X45.4' y -145.I jw 1 1 I ���� LOT 16 y 92.2 CONCRETE BOUND Q �. \ f 5 =� / / rn ,�•w 111 } i a FOUND TIPPED D �� :' / Np PROPOSED 3 BEDROOM 91.2 DWEWNG \ _ T.O.F. 93.0 \\ N /i / / PROPOSED LIMITS OF �.�_ �` �� \ j �''� 64 / \ 5.5'°°' i I EXCAVATION S�3 3 SEE NOTES PROPOSED �0,1O"F "�� _ __ ` //co m / 5 AND 6 "D" BOX ` 1 I 1 PROPOSED \\ \ '/ ! I l 1 f ) 12.83'x29.5' 2$.8' coo l t LEACHING S.A.S. �r \ �// 0)• 1 I l�tNOFW PROPOSED ` 24 i 2Ss 1500 GALLON \\ X29' _ -3:1--_ j I c PLAN VIEW LOT 15 SEP11C TANKEXISTING ` \ TP#1 / !I \ I c SCALE: 1' = 20 FEET DWELLING TO BE REMOVED c�Q / 1 ,sTE \ PROPOSED - 0 10 20 40 FT. \ NEW DWELLING 64'-2"x23'-8" ` REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6, REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A 04 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 457 BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 107,100% MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 07.-207 MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 07,5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO 1NE STA.^T... OF B. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION, CONFIRM LOCATION & NUMBER OF INVERTS. 10. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. �✓ `� �... 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 5087788 19 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR/UPGRADE #94 CRANBERRY LANE SOUTH YARMOUTH MASSACHUSETTS PREPARED FOR: CRAFTSBURY COMPANY, INC. LADD KAUTZ 845 MAIN STREET, ROUTE 28 SOUTH YARMOUTH, MA 02664 (508) 760-0500 DATE: AUGUST 23, 2006 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D. GAZZOLO / J. MCCARTIN FILE NO. 9156-SEP.DWG DWG N0, 5383-02 JOB NO.4-9156.00 SHEET 1 OF 1