Loading...
HomeMy WebLinkAbout176 Cranberry Lane Site and Sewage PlanASSESSORS MAP: 128 PARCEL: 14.2 CURRENT ZONING: R-40 MINIMUM BUILDING SETBACKS: FRONT: 30' SIDE: 20' REAR: 20' FLOOD ZONE: C P (40,295 SF) 4P� of //98 BENCHMARK AT96 /' MAG NAIL / / ELEVATION = 100.0 `f, 944` 0 ' / / 92 98.8, / / % , / /90 98.8 p 88 99.1 92 ��� °P� ' � GQ� / J'• / / / � I I � 94 99.5,+0 100` 1 ® 4 ��� 4 ! / 102 I 44/104 6 84 96 86 /! / 94 \ \ \ \ `� \ � �•. 444',' ! I / . 92 104 102 j \ --98 KEY: EXISTING CONTOUR: - - - PROPOSED CONTOUR: ...................... EXISTING SPOT ELEVATION: 25.5 PROPOSED SPO�ELEVATION: 125.51 TEST HOLE: UTILITY POLE: -0- FENCE LINE: - - - HYDRANT: -C)- RETAINING WALL: JOB # M4-23 TEST HOIJE LOGS ENGINEER: THOMAS McLELLAN, P.E. 5 BEDROOMS AT 110 GAL / DAY = 550 GAL / DAY WITNESS: DAVID FLAHERTY, R.S. DATE: 1-12-05 PERCOLATION RATE: < 5 MINT/ INCH TH-1 91.5 TH-2 86.0 ELEV. ELEV. O/A HORIZON O/A HORIZON BDTTOM AREA: 43.5'x 12.2' = 531 SF (0.74) = 393 GAL/DAY LOAMY SAND LOAMY SAND M IOYR 311 91.0 10-1 IOYR 311 85.2 B HORIZON B HORIZON LOAMY SAND LOAMY SAND „ 10YR 516 88.5 48„ 10YR 516 82.0 C HORIZON C HORIZON LOAMY SAND LOAMY SAND 2.5Y 613 2.5Y 6/3 168"1 177.5 144"1 1 74.0 NO GROUND WATER ENCOUNTERED NOTES: - 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 LOADING SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3'. 11. ALL UNSUITABLE SOIL (B HORIZON, APPROX. 48" DEEP) WITHIN Y OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 14' SCR "".' PCH DECK 24' 37'8.5" PROPOSED 28' 5 BEDROOM 28' 1315" DWELLING GARAGE PRCH 24'3.5" 1 38' PROPOSED DWELLING 2" PEASTONE COVERS WITHIN 12" OF 100.0 FINISED GRADE 40 3/4"- 1 1/2" TOP OF FOUNDATION (ONE INSPECTION COVER WASHED STONE l x1' TO BE WITHIN 6" OF GRADE) 040CA 3' MAX. S TEE AT INLET' OMIN� ELEV.= 85.0 87.75 ELEV. 84.77 84.6 88.0 1500 GAL ELEV. ELEV. e o ELEV. '`3 ,• 82.5 SEPTIC TANK D -BOX 4 > f4 ELEV. (6" OF STONE UNDER" 90.0 (6" OF STONE UNDER OR 43.5' ELEV, MECHANICALLY COMPACTED) (UNDER SLAB) GAS BAFFLE 84.5 5 INFILTRATOR CHAMBERS (MODEL 3050) WITH 4' OF STONE ALL AROUND TEE SIZES: AT OUTLET TEE ELEV. (43.5' x 12:2' x 2' DEEP) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN �sw•rR C. L✓ xr- Rl.37ml Z/�jl LITHOMAS McLELLAN, P.E. MICHAEL LADE, P.L.S. P.O. BOX 1163, EAST DENNIS, MA 02641 51 CAPTAINS VILLAGE LANE 308-395-3426 BREWSTER, MA 02631 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 5 BEDROOMS AT 110 GAL / DAY = 550 GAL / DAY SEPTIC TANK: 550 GAL / DAY -1-2- DAYS = 1100 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 5 INr TRATOR CHAMBERS (MODEL 3050) WITH 4' OF STkun,; ALL AROUND (43.5' x 12.2'x 2' DEEP) SDE AREA: (43.5' + 12.2') x 2 x 2 = 223 SF (0.74) = 165 GAL/DAY BDTTOM AREA: 43.5'x 12.2' = 531 SF (0.74) = 393 GAL/DAY N M CAPACITY = 558 GAL/DAY h r-- SEPTIC SYSTEM SECTION NOTES: - 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 LOADING SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3'. 11. ALL UNSUITABLE SOIL (B HORIZON, APPROX. 48" DEEP) WITHIN Y OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 14' SCR "".' PCH DECK 24' 37'8.5" PROPOSED 28' 5 BEDROOM 28' 1315" DWELLING GARAGE PRCH 24'3.5" 1 38' PROPOSED DWELLING 2" PEASTONE COVERS WITHIN 12" OF 100.0 FINISED GRADE 40 3/4"- 1 1/2" TOP OF FOUNDATION (ONE INSPECTION COVER WASHED STONE l x1' TO BE WITHIN 6" OF GRADE) 040CA 3' MAX. S TEE AT INLET' OMIN� ELEV.= 85.0 87.75 ELEV. 84.77 84.6 88.0 1500 GAL ELEV. ELEV. e o ELEV. '`3 ,• 82.5 SEPTIC TANK D -BOX 4 > f4 ELEV. (6" OF STONE UNDER" 90.0 (6" OF STONE UNDER OR 43.5' ELEV, MECHANICALLY COMPACTED) (UNDER SLAB) GAS BAFFLE 84.5 5 INFILTRATOR CHAMBERS (MODEL 3050) WITH 4' OF STONE ALL AROUND TEE SIZES: AT OUTLET TEE ELEV. (43.5' x 12:2' x 2' DEEP) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN �sw•rR C. L✓ xr- Rl.37ml Z/�jl LITHOMAS McLELLAN, P.E. MICHAEL LADE, P.L.S. P.O. BOX 1163, EAST DENNIS, MA 02641 51 CAPTAINS VILLAGE LANE 308-395-3426 BREWSTER, MA 02631