Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout186 Cranberry Lane SewageSOIL TEST PIT DATA
NOT TO SCALE
TEST PIT TP -1
GRD. EL 42.5
SHGW EL 31.
EL 41.8
EL 40.5
EL 38.2
EL 31.9
Ap
SANDY LOAM
10YR 2/1
9'
Bw
LOAMY SAND
10YR 5/8
2,
C
MED/COARSE SAND
2.5Y 5/4
NO
GROUNDWATER
OBSERVED
v
52"
27'
ONSITE SOIL EVALUATION
DATE: OCTOBER 17, 2013
TEST BY: BSC GROUP, INC.
WITNESSED BY: PHILIP RENAUD
LICENSED SOIL EVALUATOR: BRIAN G. YERGATIAN, P.E., SE x:3009
PERCOLATION RATE: 3 MINS/INCH
SOIL CLASS: CLASS 1
LT.A.R.: 0.74 GPD/S.F.
LEGEND
UNSUITABLE
LjMATERIALS
(TO BE REMOVED)
PERCOLATION Z ESTIMATED
TEST RANGE = SEASONAL HIGH
GROUNDWATER
REMOVABLE 6' MAX.
COVER -1
HDPE RISER
�3.--21"�
2' WALLS
- T
T
9-1/2"O O I (5) 5• DIA. I•
13" I KNOCKOUTS
11-1/2" 1 TYP'
L..L7_
2'
BOTTOM ON LEVEL . MINIMUM
STABLE BASE 3/4' TO 1-1 /2• Pp AN
CRUSHED STONE
SECTION VIEW
NOTE
1. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR
IN PUMPED SYSTEM.
2. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL
3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT.
4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR.
5. CONCRETE COVER SHALL BE RAISED TO WITHIN 6 INCHES OF FINISHED GRADE.
LOCUS INFORMATION
CURRENT OWNER:
THE CRANBERRY COVE TRUST
DEED REFERENCE:
BOOK 12983, PAGE 142
PLAN REFERENCE
BOOK 555, PAGE 74
ASSESSORS MAP:
128
PARCEL:
14.1
RESIDENTIAL ZONE:
"R-40-
SETBACKS:
FRONT 30'
4• INVERT AT DIST. BOX (OUT)
SIDE 20'
F
REAR 20'
MINIMUM LOT SIZE:
40,000 S.F.
FLOOD ZONE:
"C•, DATED 7/2/92
G (BRKOUT 39.83)
PANEL #250015 0002 D
DESIGN _ CALCULATIONS
4
o.
0
0
0
M
J
a
EX. SEPTIC TANK AND
PUMP CHAMBER TO BE
PUMPED DRY, FILLED
W/CLEAN SAND, CRUSHED
AND ABANDONED IN PLACE
N
MICHAEL P. LAVIGNA
ASSESSORS MAP 128
SYSTEM PROFILE
NOT TO SCALE
El -=A
4' SCH. 40 PVC
L=10.5 FT.
S=0.027
5 OUTLET
D -BOX
SEPTIC TANK
NOTE:
MAGNETIC REFLECTIVE TAPE SHALL BE PROVIDED IN
THE TRENCH OVER ALL PVC PIPING
BENCHMARK:
DRILL HOLE IN
CONCRETE BOUND
EL 25.20 NGVD Qy yLo
OAK TREE TO BE
VISTA PRUNED WF#��4
4• SCH. 40 PVC
L=60± FT.
S=0.015
FIRST PIPE LENGTH
T
4�FC
R MIN. 2' FINISH GRADE
EL=42.5±
H. 40 PVC
LEACHING CC33 ECM3 =CM CC33 CHAMBER
1=G ==o======_
-F H
5.1' SEPARATION
J 1
EST. HIGH GROUNDWATER
;i �,p ' ,• � Wn#,
off' •
-Y�
DOCK
#5 ,
PARCEL 13 GES D6I1110\1
i
to mG W ECONp t0 \ V •� �OpO
;n\ --BEDRQf�M JR \ WF#6
A \ � �N �
Tye �36.V
500 GAL. PRECAST '\ 3 p \ ?O Fe
CONCRETE LEACHING ) 9 ��` �o \� \ \ 9
CHAMBER (TYP.) / i 1 40 \ \\\ .o \ \ �TREE�r� R OVE :CWF
#8 p!y
h.�p .v
41 \ ^O� ��`�� \\ � 7� wq TOP OF COASTAL BANK
A6 �� �L �. \. \\\ \ ` WF# 9 • . (TYP.)
PROPOSED
LEACHING FIELD
BENCHMARK: 59.0' X 10.83' / / 42 GARAGE \\ \\\\ •\
EXISTING WATERJ8 ` \ \\3` pis ..�N.. ` \� WF#11 .
:ATE IN DRIVEWAY. �'\.- \\�
ELEV 42.50 NGVD
LOT 3
4,050± S.F. WETLAND
83.675± S.F. UPLAND
87,725± S.F. TOTAL
NOT TO SCALE
NOTES MIN. 20' DIA. COVER, TYP.
1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. RAISE (2) TO WITHIN 6" OF FINISHED
2. SEPTIC TANK SHALL BE CAPABLE OF WITHSTANDING H-20 GRADE USING SEWER BRICK AND
LOADING. MORTAR AS NECESSARY
3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION
SHALL BE WATERTIGHT. 6" MAX
4. TEES SHALL BE SCH. 40 PVC AND SHALL BE LOCATED
WITHIN 12. OF TANK WALL AND ACCESSIBLE FROM TANK
COVER.
5. FILL ALL UNUSED KNOCKOUTS WITH HYDRAULIC CEMENT.
6'
11'-0' I
I
r
L
FIELD r
N0.38039
Pee.
��" ✓ �1 I/S/ 2013
6 BEDROOMS O 110 GPD/BEDROOM - 660 GPD
REQUIRED SEPTIC TANK
660 GPD X 200% - 1.320 GALLONS
USE 1,500 GALLON SEPTIC TANK
cnE OF REQUIRED LEACHING FACILITY
DESIGN PERC. RATE: <2 MIN/INCH
LONG TERM APPL RATE: 0.74 GPD/SF
660 GPD + 0.74 GPD/SF - 892 SF
CITE OF LEACHING FACILITY PROVIDED
USE (6) 500 GALLON CONCRETE LEACHING CHAMBERS IN TRENCH
CONFIGURATION WITH 4' STONE ON ENDS AND 3' STONE ON SIDES.
BOTTOM AREA: 59' X 10.83' = 638.97 S.F.
SIDEWALL AREA: 2 X (2 X (59' + 10.83')) - 279.32 S.F.
EFFECTIVE LEACHING AREA - 918.29 S.F.
918.29 S.F. X 0.74 GPD/S.F. - 679 GPD (INSTALLED CAPACITY)
679 GPD > 660 GPD (19 GPD RESERVE CAPACITY PROVIDED)
LOT 2
293± S.F. WETLAND
40.296± S.F. UPLAND
40,589± S.F. TOTAL
01 PATIO \\ \ �: \ , SiIIt
/ + PROPOSED \ %N. �
/ 5 -BEDROOM
OB�1:: TP -1I I / DWELLING/e . \\\� \ •�.
L D -BOX S , � S•) POOL
'•
- - - - MILE_ DRIVEWAY oM W \ ` /r
ko/ / 110 8 w a2 \ \ SEPRTIOGPOANKt \ ^�� ✓ _~ X22 c.
----- /
SH
X 1 \
a \ \NEW
�\ \ \ INVASNE SPECIES SHALL BE
\ \3/ 00 WATER \\ y ? 42 / 'S J i 30 / \ \ ` REMOVED AND TREATED AS
\\\ \ SERVICE / / o COTTAG ' / I L% \ NEEDED
s �x SHED TO BE
RELOCATESTAKED �ILT
9
w
1 g�g• I ' \ X x �` NEW UNDERGOUND
6•I $ I I I' o \ \ N I {
SERVICE
I/r/
OWNER 2_/5/ _
INVASIVE SPECIES BE
CI 26 REMOVED dTHE AREA
I t , n <•. �> i Ajo ¢ / 2ti SHALL BE REPLANTED
TENNIS COURT
J --••tI J 1 1/I
` \ d 9� /
I I I 0)\A` X /" \ / l /ll `// �j/ //�` j �,,5- g"L FINE
n I I 1 12j3j' `-co
/ /� / 1/ '�E�ARRS MAP CF�L`18 128
71
500 GALLON CON(
NOT TO SCALE
LOCATELIQUID
DEPTH
INLET TEE OUTLET TEE
UNDER &07[ W/GAS BAFFLE
SCHEDULE OF ELEVATIONS
TOP OF FOUNDATION
45.50± A (MATCH EXISTING)
4" INVERT AT BUILDING
40.80
B
4• INVERT AT SEPTIC TANK (IN)
40.52
C
4" INVERT AT SEPTIC TANK (OUT)
40.27
D
4" INVERT AT DIST. BOX (IN)
39,37
E
4• INVERT AT DIST. BOX (OUT)
39,20
F
ELEVATIONS AT LEACHING FACILITY:
BRIAN G. YERGATIAN DATE
PROFESSIONAL ENGINEER
4" INV. AT LEACHING CHAMBERS
39,00
G (BRKOUT 39.83)
BOTTOM OF LEACHING CHAMBERS
3700
H
ESTIMATED SEASONAL HIGH GROUNDWATER
3784
U
GENERAL NOTES
1. THIS PLAN IN ONLY INTENDED FOR THE PERMITTING AND CONSTRUCTION OF THE
SEWAGE DISPOSAL FACILITIES AND THE NEW BUILDING.
2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO 310 CMR 15.000
AND YARMOUTH BOARD OF HEALTH REGULATIONS.
3. THERE ARE NO KNOWN OR PROPOSED PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE
PROPOSED LEACHING FACILITY.
4. EXISTING UTILITIES WHERE SHOWN ON THE PLANS ARE APPROXIMATE. THE ENGINEER
DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL SUBSURFACE STRUCTURES ARE
SHOWN. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION AND ELEVATION OF INVERTS
OF UTILITIES AND STRUCTURES, WITHIN THE LIMIT OF WORK, PRIOR TO THE START OF
CONSTRUCTION. IF ANY DISCREPANCIES ARE DISCOVERED OR FIELD CHANGES
REQUIRED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY COORDINATING THE
PROPOSED CONSTRUCTION ACTIVITIES WITH DIG -SAFE AND THE APPLICABLE UTILITY
COMPANIES, AND SHALL COMPLETE THE PROPOSED WORK WITHOUT ANY INTERUPTIONS
IN SERVICE.
6. CONTRACTOR IS REQUIRED TO NOTIFY DIG -SAFE, PER MASS. STATUTE CHAPTER 82,
SECTION 40 (1-888-344-7233) A MINIMUM OF 72 HOURS PRIOR TO THE START OF
CONSTRUCTION.
7. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. INSTALLATION
OR USE OF A GARBAGE GRINDER AT THIS PROPERTY IS NOT ALLOWED PER 310 CMR
15.240(4).
+ I I /z12 4' k / / •/ / / �� • Y WF#104 4• PERFORATED PVC
W/SCREW CAP TO EXTEND DOWN
/WF03 0 TO NATURAL SUBGRADE
/•OD
BORDERING VEGETATED
11 O
S88-23'1 7W ( I I �� I I I ; { WETLANDS 5' DIA. KNOCKOUT (TYP.) 777-77
I
IGft k -Fl- 1
20" ACCESS COVER
TO WITHIN 3 INCHES
OF FINISH GRADE
LOAM AND SEED I
ALL DISTURBED AREAS
A\���6 \ 40.59
y J�1`lWF/102 � 1-1/2• TAPER HDPE O12 -3C6]• COyF101 RPEVER
2' LAYER OF 1/8" TO
T2- DOUBLE WASHED
10' 4.\ O ONE ABOVE CROWN I
_ _ ✓ OO MM = OO OOO O C] O O of PIPE
=1 00
0 0 0 0 0
34• 24' a 0 0 0 0
/
EFFECTIVE in�� 3/4" TO 1-1/2-
_43- 1t 0 C]] M= M= ] M DOUBLE WASHED/ STONE TO CROWN]]] ]
17 CONCRETE OF PIPE
BOUNDS
?10'
8,-6• 12' 10'
FRONT VIEW SIDE VIEW
NOTES
1. ONE ACCESS COVER PER SYSTEM SHALL BE RAISED TO FINISH GRADE
2. CHAMBERS SHALL BE 500 GALLON BY SHOREY
3. GEOTEXTILE FABRIC MAY BE USED IN LIEUINOF DOUBLE WASHED STONEDFl
WHERE SPECIIEEDAPPROVED EQUAL
4
M• °� [00P75 Pond
VaIhAa Of
CV'
4. Z LOCUS
" o
rt
mob. ..
LOCUS MAP
NOT TO SCALE
"OF
BRIAN
o YE AT
C VILE �
9�F FOl EP 4,
FSS/ONA a
iW/t1�/t3
BRIAN G. YERGATIAN DATE
PROFESSIONAL ENGINEER
SEWAGE DISPOSAL
SYSTEM UPGRADE
186 CRANBERRY LANE
IN
YARMOUTH PORT
MASSACHUSETTS
(BARNSTABLE COUNTY)
SITE PLAN
NOVEMBER 8, 2013
NO.
DATE
DESC.
1
11/18/13
ADDITIONAL BENCHMARK
Yarmouth Health Department
�P
Z�VED
Date
PREPARED FOR:
THE GREAT ROOM COMPANY, INC.
165 WATER STREET
NEWBURYPORT, MA 01950
El BSC GROUP
349 Route 28, Unit D
W. Yarmouth, Massachusetts
02673
508 778 8919
© 2013 BSC Group, Inc.
SCALE: 1" = 30'
0 15 30 60 Fw
FILE: P:\prj\4979800\Civil\-Drowings\4979800-SP.dx
DWG. NO: 5383-03
SHEET 1 OF 1
JOB. N0: 4-9798.00