Loading...
HomeMy WebLinkAbout223 Cranberry Lane - Septic Design 2GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM /S ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1-888-344-7233 AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED. BACKFILLED WITH CLEAN SAND AND COMPACTED. 9. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 10. THE ENTIRE LOT IS SHOWN TO BE WITHIN FLOOD ZONE B ON MAP NO. 250015 0006 D DATED 7/2/92. 79.47 BM TOP OF CB EL -40.87 40.7+ IX1ST/NO DWELLING TO BE REMOVED 40.4 Y uv ACCESS COVERS MUST BE WITHIN 6' OF F!NlSHGRA FIRST 2' TO 7\ BE LEVEL, T 38.0 T oAs 37.5 9' MINIMUM. 3' MAXIMUM COVER MIN 2' OF PEASTONE 3/4' - 1 1/2' DIA. WASHED STONE p /3 OUTLET 3-500 GAL LEACHING CHAMBERS \\�L// D -Pox W/4• STONE AROUND. 12.6'X 33.5'X 2' 1500 GAL SEPTIC TANK 6' CRUSHED STONE BASE PROFILE:NOT TO SCALE 6RY _4 . z. pl?Y a e a 0 Z 1 _ 1 ar. 40. J(a I0� IMSOArrl W :I eARA&C 40.7 {40, e PROPOSED F" eEDROO,M ••'DRYMELC : DWELC INp• 7OF - 42.0 4o.P+ 1500 OAL INVERT IN SEPTIC TANK: SEPTIC TANK 3-500 SAL I .: OVERFLOW LEAdfINO CHAMBER r/4• STONE AROUND 40.5_, � /0' OAKS 'AIT Is TP41 Is 40.0 40. Jjyi yy '� I 10. OAK L 0 T 42 I 16825 t S.F. D-epx I � 1 RESERVE• �� , t........... 1. .40.4 I 41.0 !9 INVERT ELEVATIONS INVERT AT BUILDING: 39.0 INVERT IN SEPTIC TANK: 38.25 INVERT OUT SEPTIC TANK: 38.0 INVERT IN DIST. BOX: INVERT OUT DIST. BOX: 37.33 INVERT IN LEACH CHAMBER: 37.2 BOTTOM OF LEACH CHAMBER: 35.2 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE *1: 30.2 �l DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EQUALS 440 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 440 0. P.O. X 2002 - 880 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS - 1 EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REOUIRED PROVIDED: 3-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-614 S.F. S 0 L L TEST FIT DA TA INDICATES_y_ INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP • l 0' HORIZON TEXTURE COLOR 40 2 JALOAMY 10 YR SAND 2/1 2" -4 .......................... - 40.0 LOAMY IOYR SAND............5/2.... 8- J....E....... 39.5 B LOAMY 7.SY SAND 3/4 24' ........................ 38.2 C I Cl MEDIUM IOYR 6/8 4A 44' 1 NO WATER 30.2 DATE: DECEMBER 22, 1997 TEST BY: STEPHEN HAAS WITNESSED BY: MARINA FROCK PERC RATE: ! 2 MIN/INCH SEPT/C SYSTEM CES /G/V 223 CRAIVB E_RR Y ROAD . MAP 22 . PARCEL B-1 S O O T f- YA R"O U T H, "A.