Loading...
HomeMy WebLinkAbout31 Crowell Road - Site & Septic PlanTop of Foundation El. 103.5' INV EL 100.0" g- Ite Fmish Grade EL 10181 INV ELII U._ Beloit Fle- Line 99.40' Liquid Leve! 48- 1500 GALLON SEPTIC TANK PRECAST REINFORCED CONCRETE DISTRIBUTION BOX Install on a level base Minimum wall thickness = 2" Minimum inside dimension = 12" Outlet inverts shall be equal to each other and at 2" minimum below inlet invert. The distribution lines from the distribution box shall all have equal inverts as determined by flooding the distribution box to the height of the distribution line invert after all lines have been sealed in place. Invert adjustments shall be made by filling with durable and nondeformable material permanently fastened to the line or reconstructing the lines until all inverts are of equal elevation. AE��s t �� �i 1L � . V� � � INV EL 99.15' BRKN. CB FND. 102 100 PROPOSED SAS CHAMBE TRENCH PROPOSED - 1500 GALLON REINFORCED CONCRETE SEPTIC TANK 1500/GAL Minimum Construction Materials Per 310CMR 15.226(2) TANK Tees shall be constructed of Schedule 40 PVC and shall extend a minimum of, 6" above the flow line of the septic tank and be on the centerline of the septic tank located directly under the clean-out manhole. The inlet .pipe elevation shall beno less than 2" nor more than 3" above the invert elevation of theoutlet pipe. Septic tank shall be installed level and true to grade on a level, stable base that has been mechanically compacted and on which 6" of crushed stone has been placed to ensure stability and to prevent settling. Septic tank shall have a minimum cover of 9'. Two 20" manholes with readily removable impermeable covers of durable material shall be provided with access ports. The outlet tee shall be equipped with gas baffle. Design Da ta: Three Bedrooms = 3 X 110 gpd = 330 gpd Required Flow No Garbage Disposal Allowed Use: Chamber Trench 251 x 12'W x 2' Eff/Depth [25' t 25' -1- 12' -h 12J x 2.0 148sf 25' x 12' = 300sf 448 x 0.74 = 331 GPD Total Design Flow GENERAL CONSTRUCTION NOTES L All the workmanship and materials shall conform to REP Title 5 and the Town of Yarmouth rules and regulations for the subsurface disposal of sewage. 2. At least one access port over tank tees shall be accessible within 6" of finish grade, with any remaining access ports_______- brought to within 6" of finish grade. 3. All components of the sanitary system shall be capable of withstanding H-10 loading unless they are under or within 10 ft of drives or parking. H-20 loading shall be used under or within 10 ft of drives or parking unless noted. Plastic equals may be used in lieu of all precast units. 4. The excavator/contractor shall call dig safe and verify the location of all site utilities prior to any excavation, and shall be responsible for all matters relating to electric easements 5. Sewer pipes shall be 4" Schedule 40 PVC laid at a min. 0.02 slope. 6. Any masonry units used to bring covers to grade shall be mortared 1n place. 7. Finish grade shall have a minimum slope of 0.02 ft per foot. 8. The excavator/contractor shall be responsible to check all grades and elevations and to contact Doyle Associates of any discepancies prior to construction. 9. The excavator/contractor shall be responsible to contact Doyle Associates 24 hours prior to any required inspections. 1V W. of Ftaish Grade EL 1018'1 - I - 1/8". to 1/P' Wesbed Stone ® 3' Thick �W, EXIST. WATER LINE 1t.--- 6" 104 h- 12.0' Finish Crede El IOL B't Afar. eo,l EXISTING ELEC/POLE --__ __i .Q... rr !llllllllll 111111111111111111111111111111111111!!1 s•' ullllrllrllulllulullllullllllrllllll 34" ..° o e �:. 24" �, RISER X3.6 a.e' 85' 98.83' 58" I�C�O _ _ s "p INV EL f�OO 7NV EL ° p ° m e _ e e e _ _ _ _ El. 96.0' INV EL 98.30• 98.50 "e" stone, : ; Number of Trenches - 1 Number of Chambers - 2 98.0' 8" S/4" - 1 1/2" reseed stone 8" 25 4 HOLE DISTRIBUTION BOX PROPOSED LEACH TRENCH - END VIEW N. T. S. Install Two 500 Gallon Units with 3.6' of Stone at Sides and 4'. of Stone at Ends. PROPOSED LEACH TRENCH ' 125.00 Bu: CB FND. EL. 105.01' Bottom of Deep Observation Hole El. 91.3' DATUM. ASSIGNED High Ground Water <Elev. 91.0' (Observed) 25' ' 41' 1p4 0 PROPOSED I i Z N SAS RESERVE 042,_ 25.00 -� ABANDON /�EXISTING Z a -- LEACH PIT 0- PUMP AND 0 20' / REMOVE TANK 50.T < CL -102 r 26.00 �RADDI-no" (7E 1 .2'* EXp�CKG 14 \ 1 ANG, 3, SED,R,� j M i1jWELIING #51/ 32.2' j 1 i 1 LOT 19 G i1 i 15,000±SF r t o 1 1 1 � G W j 9 / I E{ -_ EOG E -- 100.53 100.11' CAL Health Agent.- Amy V.)n Hone RS Test Date: 06-14-07 Soil Evaluator.- S. Doyle TH #1 EL 101.0' PERC <2 MIN/INCH A SL 10YR 3/2 6" B LS 10YR 5/6 EL. 99.0' 24" PERC 48" C FINE SAND 2.5Y 6/3 120" NO WATER ENCOUNTERED EL. 91.0' 100.88' ROAD Lz:) _L_EGE=1V 35 - EXISTING CONTOUR �W, EXIST. WATER LINE 1t.--- EXIST. GAS LINE 104 PROPOSED CONTOUR X 101.34' SPOT ELEV. eo,l EXISTING ELEC/POLE --__ __i 125.00 PAVEMENT -- 101.34 TH 12 EL 103.0' PERC <2 MIN/INCH 0" A SL 10YR 3/2 6" 8 LS I OYR 5/6 t" !KIST COP TM.a EL 100.0 36'E' 13 AM A1WUTV!3 C yTh �rA 7 FINE SAND 2.5Y 6/3 120" NO WATER ENCOUNTERED EL 93.0' LOCUS CAMELOT TOM ROAD MATHEWS POND Z N� ROUTE 6A Gy 'oy s� P� F� Vt re MOCK RD -LOCZJ,S' MAP GRAPHIC SCALE 20 10 ( IN FEET ) I inch = 20 ft. REFERENCE PLAN LC 23134B REFERENCE CERT.- 137219 ASSESSORS DATA. - MAP 133 PARCEL 8 FEMA DATA: ZONE "C" PANEL 250015 0001 D MAP REV- JULY 2, 1992 80 SITE AND SEPTIC PLA Prepared For. 51 CAMELOT ROAD In `�^�tr�tkpr� Yarmouth, Massachusetts Scale: .1 = 20' Date: June 19, 2007 Prepared fiats Stephen J. Doyle and sociates 42 Canterbury Lane, E FalmoutA 3!A 02536 �Denaaaa Telephone: 508/540-2534 ySH OF,;tls� vD� ��GsT'aFs�yc°v R e vi s i o z X3I o c I a CHRISTINE iS Y. 11 c STEPHEN FAIRNENY nuI� -' No. 926 d4 DOYLE a p pFGISTI-��O SAIr1TAF1p�1 �,s� UR ..C'a DATE DESCRIPTION BY