Loading...
HomeMy WebLinkAbout74 Crowell Road - Site PlanLEGEND PROPOSED SYSTEM PROFILE 100.0 PROPOSED SPOT ELEVATION TOP FNDN. AT EL. 16.0'± (NOT TO SCALE) _ NOTES oute 28 „ MAGNETIC TAPE OVER ALL PLASTIC COMPONENTS FOR FUTURE LOCATION - 100x0 EXISTING SPOT ELEVATION ACCESS COVERS TO WITHIN 6 OF GRADE ///--- ACCESS COVER (WAIERT:GHT) TO PROVIDE INSPECTION PORT TO WITHIN 3' OF FINAL GRADE MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE (C.I. COVER TO GRADE IF PAVED) LOCUS 100 PROPOSED CONTOUR 9` 15.2' 25 SLOPE REQUIRED OVER SYSTEM 13.1' 1. DATUM IS APPROXIMATE NGVD 100 EXISTING CONTOUR 13.1' /� RUN PIPE LEVEL �� 2. MUNICIPAL WATER IS EXISTING PROPa(H %-FOR FIRST 2' 2' DOUBLE WASHFID PEASTONE GAL�r}�-�{1�/ OR GEOTEXIILE FABRIC 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. CP EXISTING CESSPOOL 12.81' TAns 6'suMP � 12.1' 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO11.67 ![s� ee�s i�ADJ.. cRan+owAlm ELEv. 5.8' DEPTH OF FLOW = 4'AFFLE 11.84' �� c"6,�3 �8 H 20 f IL4r M® 3.0' AT SIDES FY WEE SIZES: 5. PIPE JOINTS TO BE MADE WATERTIGHT. 10 DBDX (H-20) 3.25' AT ENDS, -p INLET DEPTH - 6' CRUSHED STONE OR MECHANICAL c�o I_ Lewis OUTLET DEPTH = 14" COMPACTION. (15.221 [2D oo�b 10.8 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 3/4" TO 1 1/2" DOUBLE WASHED STONE MASS. ENVIRONMENTAL CODE TITLE V. Bay HIGH CAPACITY INFILTRATOR (H-20) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO ( 2_5 % SLOPE) (-I- % SLOPE) (1 % SLOPE) BE USED FOR ANY OTHER PURPOSE. FOUNDATION 10' SEPTIC TANK 72'LEACHING " SCALE T = 2,000' D BOX 6' FACILITY 5 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4 PVC. ASSESSORS MAP 23 PARCEL 335 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED LOCUS IS WITHIN FEMA FLOOD ZONE "B" WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION AS SHOWN ADJ. GROUNDWATER EL. 5.8' OBTAINED FROM BOARD OF HEALTH. ON COMMUNITY PANEL #250015 0005 D DATED JULY 2, 1992 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING MAX BUILDING COVERAGE: 25% DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION HOUSE & SHED: 1655 S.F.± OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOT: 7201 COMMENCEMENT OF WORK. COVERAG . 22.9% 11. EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND FILLED ZONE: R 5 SETBACKS: WITH CLEAN SAND OR PUMPED AND REMOVED. FRONT: 30' SIDE: 15' PROVIDE VENT WITHFINAL NAL x12.05 12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REAR: 20' (N/A) FILTER AND BUGSCREEN EN (FINAL PLACEMENT WITH HOMEOWNER REMOVED 5' AROUND AND BENEATH THE LEACH AREA. CONSULTATION) 13. SEPTIC SYSTEM TO BE REPLACED IN SAME AREA AS FIGS COPY / PROPOSED IF OR WHEN FAILURE OCCURS. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MEDIUM SAND. Scale:1 "= 10' 0 5 10 15 20 25 FEET DCE ##06-094 A10.67 APPROVED DATE SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW. 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 330 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (44 + 8.83) (.83) (.74) = 64.9 GPD BOTTOM 44 x 8.83 (.74) = 287.5 GPD TOTAL- 474 S.F. 351 GPD USE (6) H-20 HI -CAP INFILTRATORS WTH 3.25' STONE AT ENDS AND 3' AT SIDES TEST HOLE LOGS VARIANCES 310 CMR 15.405(1)(a) REDUCTION OF LEACHING SYSTEM LOCATION SETBACK FROM PROPERTY LINE: FROM 10' TO 5.2' 310 CMR 15.405(1)(b) REDUCTION OF LEACHING SYSTEM LOCATION SETBACK FROM CELLAR WALL: FROM 20' TO 17.4' (RESERVE: 20' TO 8.9') 310 CMR 15.405(1)(g) REDUCTION OF LEACHING SYSTEM LOCATION SETBACK TOWATER,LINE: - SLEEVED (IF NOT RELOCATED 10') TITLE 5 SITE PLAIN ENGINEER: DAVID FLAHERTY, R.S. OF WITNESS: AMY VON HONE, R.S., C.H.O. 74 CROWELL ROAD DATE: APRIL 27, 2006 WEST YARMOUTH, MA PERC. RATE _ < 2 MIN/INCH PREPARED FOR CLASS I SOILS P# JAMES O'MALLEY I� ELEV. ELEV. 0" 4 11_7' 0" 11.7' DATE: AUGUST 18, 2006 A A REVISED DATE: OCTOBER 19, 2006 (BOH) LS LS 10YR 4/210YR 4/2 14" 10.5' 12" 10.T B B Yarmout' I'er1:'_* r2.2rtrnent LS LS I'pr7 Q k 40" 10YR 5/6 8.4. 42" 10YR 5/6 da, 8.2'Name � T- C1 MS PERC 10YR 6/6 ----- -----------}-- ADJ.. GROUNDWATER 5.8' C C VeD 91" OBS. GROUNDWATER 4.1' A10 0 8 2006 C 120" 1.7' ey. Bur+.OhV MS C2 �._OE�z 10YR 6/6 VFS 96" 3.7' >120 2.5Y 5/3 >1.7' off 508-362-4541 OBS. WELL MIW-29, ZONE A fax 508 362-9880 DATE: APRIL, 2006 ADJUSTMENT: 1.7' do wn cape en gin e erin g, inc. `-- o u Cl VIL ENGINEERS rrIL7 APLAND SURVEYORS a;=.A 939 Main Street - YARMOUTHPORT, MASS. No 253• --tet %¢ , MA BOARD OF HEALTH 06-094 O'MALLEY.DWG (DDF) FILE COPY