Loading...
HomeMy WebLinkAbout74 Crowell Road - Site Plan 2_EGEND PROPOSED SYSTEM PROFILE TOP FNDN. AT EL. 16.0'± (NOT TO SCALE) NOTES 100.0 PROPOSED SPOT ELEVATION MAGNETIC TAPE OVER ALL PLASTIC COMPONENTS FOR FUTURE LOCATION ACCESS COVER WAT�2TIGHT TO PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE ACCESS COVERS TO WITHIN 6" OF GRADE ( ) (C.I. COVER TO GRADE IF PAVED) 100x0 EXISTING SPOT ELEVATION WITHIN 6" OF FIN. GFi .DE 1. DATUM IS APPROXIMATE NGVD MINIMUM .75' OF COVER OVER PRECAST 1 rJ 2' 2% SLOPE REQUIRED OVER SYSTEM T-3 11 2. MUNICIPAL WATER IS EXISTING 100 PROPOSED CONTOUR RUN PIPE LEVEL 2• DOUBLE OTEX' D PEASTONE IC 13.1' FOR FIRST 2' - 100 EXISTING CONTOUR PROPM�l OR cEOTEznLE FABRIC. 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. GAL.56' 12.1' 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO Cp EXISTING CESSPOOL 12.81' TANAs 6"suMPFFLE 11.84 1.6T OSTONE H- 20 AM. GROtMOWATM MU. s8' DEPTH of FLOW - 4' 11.63' AT SIDES5. PIPE JOINTS TO BE MADE WATERTIGHT. TEE SIZES DBOX (H-20)$ 0.83' AT ENDSSI DEPTH 10" 6" CRUSHED STONE OR MECHANICAL 0 0m 10.8' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH COMPACTION. (15.221 [21) MASS. ENVIRONMENTAL CODE TITLE V.OUTLET DEPTH a 143/4" TO 1 1/2" DOUBLE WASHED HIGH CAPACITY INFILTRATOR (H-20) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR ANY (OTHER PURPOSE. ( 2_5 % SLOPE) (-j- % SLOPE) (--L-- % SLOPE) SCALE T = 2 6' LEACHING' 5' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. ASSESSORS MAP 23 PARCELEL 335 FOUNDATION 10' SEPTIC TANK 72' D' BOX FACILITY 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED LOCUS IS WITHIN FEMA FLOOD ZONE "B" WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION AS SHOWN ON COMMUNITY PANEL #250015 0005 D ADJ. GROU"DWAR" '.:!_. 5.8' OBTAINED FROM BOARD OF HEALTH. DATED JULY 2, 1992 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING MAX BUILDING COVERAGE: 25% DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION HOUSE & SHED: 1655 S.F.± OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOT: 7201 S.F.± COMMENCEMENT OF WORK. COVERAGE: 22.9% ZONE: SETBACKS: 11. EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND FILLED FRONNT:T. WITH CLEAN SAND OR PUMPED AND REMOVED. ' SIDE: 15 REAR: 20' (N/A) 12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE PROVIDE VENT WITH CHARCOAL x1205 REMOVED 5' AROUND AND BENEATH THE LEACH AREA. FILTER AND BUGSCREEN (FINAL PLACEMENT WITH HOMEOWNER / 13. SEPTIC SYSTEM TO BE REPLACED IN SAME AREA A5 CONSULTATION)/ PROPOSED IF OR WHEN FAILURE OCCURS. INSTALL 140'± 40 MIL LINER 5' ' - HIGH POINT 12.07, / / FROM PROPOSED LEACHING AREA TOP ELEV. 12-1', SYSTEM DESIGN: ELEV. BOTTOM ELEV. 8.1'. / } - GARBAGE DISPOSER IS NOT ALLOWED VARIANCES �® DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD ® USE A 330 GPD DESIGN FLOW 310 CMR 15.405(1)(a) REDUCTION OF ExlsnNc WATER LINE To D 10• AWAY LEACHING SYSTEM LOCATION FROM PROPERTY LINE: SETBACK BE RELOCATE \ - - FROM LEACH AREA OR / SLEEVED WITHIN 10' OF X1 6. LEACH AREA 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO6g• ;`• / �j ^r�F'_LI^dG SUITABLE SOIL LAYER. REPLACE ' s A- 2 .':a-',\ WITH CLEAN MEDIUM SAND. C \ - \/ j \ / PROPOSED // 9 J � a 70 HORSESHOE / •.•..® / (P STONE DRIVE '� 9S, 85 ;.; / 1.74 X11.67 \� % PROPOSED �4 5.8 � Scale:1 "= 10' _. 0 5 10 15 20 25 FEET )r,F .406=094 3 OR DWELLING ?2 TOP, OF FNDN: �I I \\ o• (SLAB) ELEV. 16.0'± GA4AGE 5.5 X11.50 '� y EXISTING GAS LINE TO BE RELOCATED. USE EXTREME CAUTION,k�%L DURING CONSTRUCTION! ,, 15.2' � v F a ryoh �\ I, 1> LOT 3 7,201± SO. FT. C C SHE[ O (EXISTING LEACH BENCHMARK: CONCRETE BOUND TRENCH , W/ DRILL HOLE ELEV. 10.5' � X11.10 X10.67 SEPTIC TANK: 330 GPD (2) = 330 FROM 10' TO 5.2' USE A 1500GAL. SEPTIC TANK - 310 CMR 15.405(1)(b) REDUCTION OF LEACHING: LEACHING SYSTEM LOCATION SETBACK SIDES: 2 (44 + 8.83) (.83) (.74) = 64.9 GPD FROM CELLAR WALL: FROM 20' TO 17.4' BOTTOM 44 x 8.83 (.74) 2S7.5 GPD (RESERVE: 20' TO 8.9') TOTAL: 474 S.F. 351 GPD 310 CMR 15.405(1)(g) REDUCTION OF USE (6) H-20 HI -CAP INFILTRATORS LEACHING SYSTEM LOCATION SETBACK -- -- - --TO VIA -TER LINE- .. WITH 3.25' STONE AT ENDS AND 3' AT SIDES SLEEVED (IF NOT RELOCATED 10') TEST HOLE LOGS TITLE cJ SITE PLAN ENGINEER: DAVID FLAHERTY, R.S. OF WITNESS: AMY VON HONE, R.S., C.H.O. 74 CROWELL ROAD :c APRIL 27, 2006 DATE: WEST YARMOUTH, MA 2 MIN/INCH PERC. RATE _ < PREPARED FOR CLASS I SOILS P# JAMES OWALLEY 65 L I ELEV. I�-I ELEV. 0" 4 11.7' p' Q 11.7' DATE: AUGUST 18, 2006 A A REVISED DATE: OCTOBER 19, 2006 (BOH) 11.41 LS 14.8 \ LS 10YR 4/2 10YR 4/2 14" 10.5' 12" 10.7' B B LS LS / 40" 10YR 5/6 8.4' 42" 10YR 5/6 8.2' 1.o j C1 MS PROPOSED. PAVED PERC 1OYR 6/6 DRIVE ----- ----- ---- -- ADJ.. GROUNDWATER 5.8' 91" OBS. GROUNDWATER 4.1' ^p C 120" ' 1.7' h a SC2 0 " 1 OYR6/6 2.5YF 5/3 �� 96 3.7' >120 >1.7 off 508-362-4541 ® fax 508 362-9880 �® OBS. WELL: MIW-29, ZONE A Pl DATE: APRIL, 2006 ADJUSTMENT: 1.7' 1 t down cape en gin eerin g, Inc. CIVIL ENGINEERS LAND SURVEYORS AP{rE"`"' 939 Main Street - YARMOUTHPORT, MASS. o OJALA N- j� CJ3LA o CIVIL N 1 q No.2i tP No. 0792 2 Pe MA APPROVED DATE BOARD OF HEALTH A ' H. OJALA, P.E., P.L.S. 06-094 O'MALLEY.DWG (ODF)