Loading...
HomeMy WebLinkAbout86 Crowell Road - Site & Sewage Plan9 SEPTIC PROFILE T.O.F. AT EL. 1 3.4'(NOT TO SCALE) --------� ACCESS COVER TO WITHIN 6- OF FIN. GRADE ACCESS COVER (WATERTIGHT) TO J WITHIN 6" OF FIN. GRADE uwluuM .75' OF COVER OVER PRECAST RUN PIPE LEVEL j -FOR FIRST 2' 10.96' ' 10.43jjjj8CAFF8LE 9 /,76' 9 99 J 6 CRUSHED STONE OR MECHANICAL ( 2 %SLOPE) COMPACTION. (15.221 [21) DEPTH OF FLOW 44 SLOPE) (-L-7 SLOPE) TEE SIZES: 10" .INLET DEPTH OUTLET DEPTH = 14" FOUNDATION- 26.5' - SEPTIC TANK 25 5' REMOVAL OF UNSUITABLE SOIL REWIRED AROUND PERIMETER OF SYSTEM DOWN TO MED/COS LAYER. HIGH POINT REPLACE WITH CLEAN MED. SAND. LEACH FIELD O AREA O/ S ALL � 5, %•� C`2 Q / C �1 f_�5k PROP. GRAVEL DRIVE. RES PROP. SILT FENCE BA1CI(6Q BY I _ - - UNDIST( X BUFFER 6� �O 2> . 6X \ \\35' \\ \ \ _7 \ 98-242 2% SLOPE REQUIRED OVER SYSTEM 10.75' CULTEC FILTER FABRIC PER SPECb WITH 2" PEASTON i ON TOP OF FABRIC --\ 10.0' 0 0 0 0 0 0 0 0 0 0 o a o 0 0 0 0 0 0 0 0 0 0 � 9.35' I CULTEC C4 FIELD DRAIN PANELS 3/4" TO 1 1/27 DOUBLE WASHED STONE 5' LEACHING D' BOX 10' FACILITY ADJUSTED WATER EL. 4.35' WELL: MIW 29 ZONE: A ADJ: 0.4' BENCHMARK - TOP OF �I CONC. BIND. EL= 11.28 (NGVD) 1 TOP OF FNDN IS.3.4',ABOVE THE HIGH POINT IN THE ROAD sx 9.4 DECK / 9.0 8.6 LOT 17A Area = 42,270± sq.ft. 0.97 Acres 60� .• TEST HOLE TITLE 5 "MAXIMUM FEASIBLE COMPLIANCE" (UNDER 15.005, TRANSITION RULES FOR ENGINEER: D.A. ISOLATED LOT) 15.405 10: REDUCTION IN SETBACK TO PROPERTY LINES (10' TO 5') VON HONE, RS TOWN OF YARMOUTH REG. 3.7: LEACH FACILITY TO BE 86' TO THE EDGE OF WETLAND (14' VARIANCE REQ.) YARMOUTHTOWN OF RESERVE(SEEO (28' VARIANCE REQ.) NOTE BELOW) EDGE OF WETLAND PERC. RATE _ *IF PRIMARY SYSTEM SHOULD FAIL, CONTAMINATED SOILS, PLACE PER REMOVE CLEAN FILL AND PLACE NEW LEACH FACILITY IN AREA OF PRIMARY SYSTEM. I & III 98-242 2% SLOPE REQUIRED OVER SYSTEM 10.75' CULTEC FILTER FABRIC PER SPECb WITH 2" PEASTON i ON TOP OF FABRIC --\ 10.0' 0 0 0 0 0 0 0 0 0 0 o a o 0 0 0 0 0 0 0 0 0 0 � 9.35' I CULTEC C4 FIELD DRAIN PANELS 3/4" TO 1 1/27 DOUBLE WASHED STONE 5' LEACHING D' BOX 10' FACILITY ADJUSTED WATER EL. 4.35' WELL: MIW 29 ZONE: A ADJ: 0.4' BENCHMARK - TOP OF �I CONC. BIND. EL= 11.28 (NGVD) 1 TOP OF FNDN IS.3.4',ABOVE THE HIGH POINT IN THE ROAD sx 9.4 DECK / 9.0 8.6 LOT 17A Area = 42,270± sq.ft. 0.97 Acres 60� .• TEST HOLE LOGS ENGINEER: D.A. OJALA, SE WITNESS: AMY VON HONE, RS DATE: 5/28/98 PERC. RATE _ < 2 MIN PER INCH I & III N/A / CLASS SOILS P# �� 5 6 _I C� ELEV. Q 10.2' N 0^ 9.7_ C 2 LOCATION MAP SCALE 1"Ap LS0YR - L5 4/2 7" 10YR 4/2 ASSESSORS MAP 13 PARCEL Q17-1 18" B ZONING DISTRICT: R-25 B B LS YARD SETBACKS: 10YR 6/8 7'4 28" 10YR 6/8 7.9' FRONT = 30' C1 SIDE = 6' Cl MED/COS REAR = 20' MED/COS 84•. obs. water 3.2' PLAN REF. -56/9 1925 gg" obs: water 3.95' 2.5Y 6/6 FLOOD ZONE: A ELEV. 10.0' 2.5Y 6/6 114" 0.7' 108" 0.7' C2 C2 SILT LOAM SILT LOAM 2.5Y 7/2 2.5Y 7/2 120" -0_3' 126" -0.45 NOTES. SEPTIC DESIGN_ (GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS (110 GPD) = 330 GPD USE A 330 APD DFSIrN FLOW SEPTI_ 330 GPD (Z-) = 660 USE15OD-GALLON SEPTIC TANK LEACHING: N/A SIDES: = 346 26 x 18 (.74) BOTTOM: TOTAL: 468 S.F. 346 GPD USE LEACH FIELD OF 2 ROWS OF (3) C4 CULTEC FIELD DRAIN PANELS, WITH 4' OF STONE BETWEEN ROWS 3' AT SIDES AND 1' AT ENDS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION F1 001 PROPOSED CONTOUR - - 100- - EXISTING CONTOUR ® PROP. DRYWELL BOARD OF HEALTH ROVED DATE oft iox 55,W M2-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main St. yarmouth, ma 02675 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE t0 3. MINIMUM PIPE PITCH TO BE 1/5' PER FOOT. & 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASFIO 1 20 5. PIPE JOINTS TO BE MADE WATERTIGHT, 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. B. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9 COMPONENTS NOT TO INSPECTION BY BOARDBOFBACKFILLED OR CONCEALED WITHOUT HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. WATER TEST D'BOX FOR LEVELNESS. SITE AND SEWAGE PLAN OF #86 CROWELL ROAD IN THE TOWN OF: (WEST) YARMOUTH PREPARED FOR: `MICHAEL DENARO 30 n 30 60 90 SCALE: 1 - 30 DATE: SEPTEMBER 18, 1998 REV. 10/13/98 REV. 10/20/98 (CONCOM COM'S) REV. 11/3/9B (PEASTONE) ARNE H.� 9cyGs o�� ARNE QJALA 2 CIVILyn No. 3�@L Q No. 63 C ATE P.L.S. /" D