Loading...
HomeMy WebLinkAboutEngineered Plans - 2015U 1 100.23 0' 0- 100,41 100,41 100,32 X W _w LOT 53 \ LO MBLU 67-80 100,73 rn 11,080±SF O N s 100.35 m x' 100.24 OWNER OF RECORD BRUYERE, MARC D BRUYERE, KRISTEN R 46 SIERRA WAY WEST YARMOUTH, MA 02673 shr. X I •100, I EXISTING sem_ r�r HOUSE(#46) : 0. F. =101.0± DECK BH X 90.00 N 49'24 \ Pg for REPAIR" OK SEI'T1C SYSTEM t�TLL ; due to State and Coca septic variances. Board. Ilealth review and at�prov I is required for any inti a additionshcnc,v.Uions�aIterations to Ig faeih 'es and/or structsarcs/dwc�long. 100,6 \ Yarm th Health Uepartmt,nt PPROVED46�4� LEGEND --98-- EXISTING CONTOUR yv� AY x 100.98 EXISTING SPOT GRADE 46 SIERRA WAY, SOUTH -1N EXISTING WATER SERVIC IE RRA -G- EXISTING GAS SERVICE 99,75_ --0. H.14�-- OVERHEAD WIRES BENCHMARK PK SET 99,74 Z "� PK NAIL SET of 100,00 ed e avement -310 CMR 15.405(1)(h): CONTENTS OF LOCAL UPGRADE APPROVAL CL EL. =100.00 1) A 2' reduction to the 5' separation requirement between bottom 4 g0.49 2„ �- I of SAS an adjusted high groundwater, for 3' of separation. The Pipe N 100.01 S , 70 x 100.08 i / n. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 73 99,82 ( 100.20 p4 ►- 14, I� I CATCH BASIN 0 .20 1C 99.94DRIVEWAY: PAVED I 1 100.05 GA I N \ \ 100,26 x U 1 100.23 0' 0- 100,41 100,41 100,32 X W _w LOT 53 \ LO MBLU 67-80 100,73 rn 11,080±SF O N s 100.35 m x' 100.24 OWNER OF RECORD BRUYERE, MARC D BRUYERE, KRISTEN R 46 SIERRA WAY WEST YARMOUTH, MA 02673 shr. X I •100, I EXISTING sem_ r�r HOUSE(#46) : 0. F. =101.0± DECK BH X 90.00 N 49'24 \ Pg for REPAIR" OK SEI'T1C SYSTEM t�TLL ; due to State and Coca septic variances. Board. Ilealth review and at�prov I is required for any inti a additionshcnc,v.Uions�aIterations to Ig faeih 'es and/or structsarcs/dwc�long. 100,6 \ Yarm th Health Uepartmt,nt PPROVED46�4� N CoP oin 1-o hroP R ® no O LOCUS -0 O o � o 0 rt p N O SR Captain Simmons Rd a Sierra Wa Captain No es Rd LOCUS MAP NOT TO SCALE LOW VENT LEGEND --98-- EXISTING CONTOUR PROPOSED S.A.S. x 100.98 EXISTING SPOT GRADE 46 SIERRA WAY, SOUTH -1N EXISTING WATER SERVIC BOARD OF HEALTH AND THE DESIGN ENGINEER, -G- EXISTING GAS SERVICE Prepared for: D.A. Brown, Inc. P.O. --0. H.14�-- OVERHEAD WIRES S1 �G��� -U- UNDERGROUND WIRES 99;73 Z K TEST PIT -- I R 4k BENCHMARK N CoP oin 1-o hroP R ® no O LOCUS -0 O o � o 0 rt p N O SR Captain Simmons Rd a Sierra Wa Captain No es Rd LOCUS MAP NOT TO SCALE LOW VENT GENERAL NOTES: UPGRADE PROPOSED S.A.S. 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL 46 SIERRA WAY, SOUTH PRESBY Envro-Septic Pipe System BOARD OF HEALTH AND THE DESIGN ENGINEER, No. 35109 �p Prepared for: D.A. Brown, Inc. P.O. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS S1 �G��� S7RlPOUT OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE Z SEE NOTE 11 LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: -- I R Engineering Works, Inc. -310 CMR 15.405(1)(h): CONTENTS OF LOCAL UPGRADE APPROVAL o�/ Q ��GVE� 1) A 2' reduction to the 5' separation requirement between bottom O 12 West Crossfield Road of SAS an adjusted high groundwater, for 3' of separation. The Pipe o LA SES 2 2015 proposed SAS is a Presby Enviro- Septic system under Remedial Approval. �/ g 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR HEALTH DEPT TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING - EXISTING SHED FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN REMOVE & RELOCATE ENGINEER BEFORE CONSTRUCTION CONTINUES. -EXISTING S.A.S. 5, ALL ELEVATIONS BASED ON AN ASSUMED DATUM. ABANDON AND STRIPOUT UNSUITABLE 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF SOILS WITHIN 5 ' OF PROPOSED S.A.S. THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF (SEE NOTE 11) HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. - PROPOSED PUMP CHAMBER 8. THERE ARE NO ABUTTING WELLS WITHIN 150' OF THE PROPOSED S.A.S.. : 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS '-RETURN LINE FOR HIGH VENT (ROOF) AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. EXISTING SEPTIC TANK TOP OF TANK, EL. = 99.7 INV. (OUT)= 98.43.± 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. ' rvL�' y�11, WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL -UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 6 12. AS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE ' INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. ^^ 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND M�Ss9 IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. �y G o PETER T. PROPOSED SEPTIC SYSTEM UPGRADE PLAN M CIVIL EE N 46 SIERRA WAY, SOUTH YARMOUTH, MA No. 35109 �p Prepared for: D.A. Brown, Inc. P.O. Box 145, Centerville, MA S1 �G��� Engineering by: Surveying by: SCALE DRAWN JOB. NO. -- I R Engineering Works, Inc. KEngineering, Inc. 1 "=20' P.T.M. 175-15 12 West Crossfield Road 2854 Cranberry Hwy. Forestdole, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. (508) 477-5313 (508) 273-0377 8/31/15 P.T.M. 1 Of 3 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 98.40 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED D -BOX PROPOSED S.A.S. INSTALL WATERTIGHT RISER, AND INSTALL A 4" DIAM. INSPECTION PORT„ PERFORATED WITHIN S.A.S., COVER SET TO WITHIN 6" OF SOLID ABOVE THE S.A.S., WRAPPED WITH PERMEABLE FILTER FABRIC HAVING A SCREW CAP SET TO WITHIN 3" OF FINISH GRADE FINISH GRADE. LOW F.G. EL.=101.0± F.G. EL.=100.9± VENT PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP MAINTAIN 2% GRADE MIN.) OVER S.A.S. F.G. EL.=100.0± F.G. EL,=100.51 (EXISTING) f COUPLING L 8'(MAX.) INSPECTION PORT VENT RETURN TO CCD S=1� (MIN.) (ty WRAPPED WITH LEVEL PUMP CHAMBER -- 4"SCH40 PVC TOP OF SYSTEM SAND EL. 7.82 FILTER FABRIC = TOP OF PC _ -�=_=--__ J - -- ,.; ... ' EL.=9� 48 �� l -- 2" SCH 40 PVC a• Enviro-Septic Pipe* TO BE SET LEVEL INV.=99.48 _- THRUST BLOCKS AT ALL BOTT./PIPE, EL.=98.90 BOTT./SAND EL.=98.40 5 ROWS OF 3-10' Presby Enviro-Septic Pipe* SOIL LOG 14„ L=15' lo" INV.=99.82 PROPOSED INV.=99.65 1' ROW LENGTH=30' 1' DATE: JULY 2, 2015 ® S=1% (MIN.) 4"SCH4o PVC D -BOX 3' SEPARATION TO HIGH G.W.(VARIANCE) LENGTH OF SYSTEM SAND BED=32' SOIL EVALUATOR: PETER MCENTEE PE(SE#1542) INV.=97.48 WITNESS: AMY VON HONE RS HEALTH AGENT FILTEADOR EFFLUENT ADJUSTED HIGH HIGH G.W. EL: 95.4 SOIL ABSORPTION SYSTEM (PROFILE) TP G.W., EL.=95.4ELEV. SYSTEM SAND (ASTM C33) DEPTH 2 FLOATS EXISTING OBSERVED G.W., EL.=93.7 " (12ON ALL SIDES &' 6" ABOVE & BELOW PRESBY PIPE) 0„ 100.0 TANK FILL .SEPTIC INV.=98.43± OT., EL.=93.40 F.G. EL.=100.9 97.4 3t AL10YR EXISTING 500 GALLON PUMP CHAMBER 4"-6" OF LOAM AND SEED /2D (FIELD VERIFY) (H-20 RATED) 4 97.0 36" ACME-SHOREY PRECAST (PCR55) SYSTEM SAND B10YR PERC (See Pump etail, She t 3) SLOPE LOAMY30"/48" NOTES: °%i� 110YR /8D 96.0 48' 1) CONTRACTOR SHALL VERIFY ALL EXIS NG PIPE EL=100.40 C INVERTS, PRIOR TO INSTALLATION. .L.=99.48 :':,•.Y .; L.= 8.90 to"(min.) :• BREAKOUT EL_=98.40 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE EL.=98.40 ---- ON A MECHANICALLY COMPACTED SIX INCH CRUSHED 1.5' 2.75' 3 FT. SEPARATION TO HIGH G.W. MED. SAND STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). w (WITH VARIANCE) 10YR 6/4 3 INSTALL INLET & OUTLET TEES AS REQUIRED. 12' TO SLAB 5 ROWS AT 33" O.C. GW EL.=95.4 4) CONTRACTOR SHALL INSPECT EFFLUENT FILTER ON z 20' TO CRAWL SPACE BED WIDTH = 14.0' 95.4 ADJ. G.W. OUTLET TEE AND REPLACE IF NECESSARY. SEPTIC SYSTEM PROFILE SECTION AA 93.7 STG. G.W. 75" 92.0 96" N.T.S. STANDING G.W. AT EL.=93.7, USE INDEX WELL MIW-29, ZONE A WATER LE (JUNEMENT=1.7' DESIGN CRITERIA EL G.W., LDJ954 PERC RATE <2 MIN/IN. ("B & C" HORIZONS) NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I / EXISTING/ DESIGN PERCOLATION RATE: <2 MIN/IN (0.74 GPD/SF) m DAILY FLOW: 330 GPD TRI -LEVEL HOUSE(#46)1 �6' DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO T.O.F.=101.0E GARAGE �� 0 � EXISTING SEPTIC TANK: 1000 GALLON CAPACITY / PROPOSED PUMP CHAMBER: 500 GALLON CAPACITY (H-20) shr. PROPOSED D -BOX: 1 INLET, 6 OUTLETS, (H-10) LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF x`30 Cb' .74 GPD/SF USE PRESBY Enviro-Septic PIPE DECK^O 3 ' -) s A s PROPOSED SEPTIC SYSTEM UPGRADE PLAN PRESBY PIPE LENGTH REQUIRED=150 L. F, USE 5-30' LINES �\ SEO PR OPC�'' 46 SIERRA WAY, SOUTH YARMOUTH, MA Prepared for. D.A. Brown, Inc. P.O. Box 145, Centerville, MA PROPOSED D -BOX: 1 INLETS, 6 OUTLET (MIN.), H-20 SHOWN ( ) ' � � 9 INSTALL A 14' x 32' LEACH BED Engineering by: Surveying by: SCALE DRAWN JOB. NO. SIDEWALL AREA: NOT APPLICABLE r Engineering Works, Inc. 1C Engineering, Inc. N.T.S. P.T.M. 175-15 BOTTOM AREA: 14' x 32' = 448.OSF S.A.S. LAYOUT 12 West Crossfield Road Forestdale, MA 02644 2854.Wa Cranberry Hwy.reham, MA 02538 E .Wa SHEET NO. DATE CHECKED LEACHING CAPACITY PROVIDED: 0.74 GPD/SF x 448 SF = 331.5 GPD (508) 477-5313 (508) 273-0377 8/31/15 P.T.M. 2 Of 3 NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID—TIGHT CABLE CONNECTORS SUPPORTED PROVIDE WATERTIGHT CONCRETE RISER WITH BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE SECURED FRAME & COVER TO GRADE WATERTIGHT. USE SJE RHOMBUS—JB PLUGGER OR EQUAL. PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP HOISTING CABLE 7x19 STAINLESS STEEL INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. VIRE HIGH WATER ALARM 6' 1/8" DIAMETER. / 1,760 LB. STRENGTH. FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL L ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. INV.(IN)=97.48 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) (INSTALL QUICK DISCONNECT FOR EASY REMOVAL) \ ___-- 2"SCH. 40 DISCHARGE (THROUGH RISER—SEE PROFILE) ALARM ON EL:96.07 2" 90' ELBOW W/ 1/4" WEEP HOLE PUMP ON EL: 95.06 SELF—DRAINING FORCE MAIN fFOR PUMP OFF EL: 94.73 24" 12» 2" SWING CHECK VALVE \ �'-,-� / 24" DIAM. OFFSET OPENING •T BOTTOM OF 8 2 SCH. 40 PVC DISCHARGE PIPE PUMP CHAMBER ELEV.= 93.40 —=—•=L8 ' ADDITIONAL 3/16" VENT HOLE ,(MIN.) ABOVE PUMP FLANGE PROVIDE 2 FLOATS: (TO PREVENT PREMATURE PUMP BURNOUT) 100 FLOAT NO.1: PUMP ON/OFF—POLYLOCK FLOAT PROVIDED WITH PUMP TT _FO FLOAT NO.2: ALARM ACTIVATION FLOAT—PROVIDED WITH ALARM PANEL POLYLOCK PL—EF 05W PUMP .5 H.P. 115 V (ON SEPARATE CIRCUIT FROM PUMP SPECIFIED) WITH 2 DISCHARGE, OR EQUAL 1 I PUMP CHAMBER, PUMP & ACCESSORIES AVAILABLE AS A UNITZ�c I I ACME-SHOREY PRECAST CO., HARWICH, MA. (508) 548-9607 x I I NOTE: APPROVED ALTERNATE MAY BE SUBSTITUTED.' I PUMP DETAIL I I I I I L-------- J 0 --�6'-- I BUOYANCY CALCULATIONS 6-5" OUTLETS 24" H-20 MONOLITHIC 500 GALLON PUMP CHAMBER ITEM # PCR55 BOTTOM OF UNIT EL.= 93.40 y• . ,,:: ;,.; SPECIFIED WEIGHT=11,795 LBS. H-20 4" 16" 4" HIGH GROUNDWATER EL.=95.4 (ADJUSTED) 1-5" INLET BUOYANCY FORCE PER FOOT OF DEPTH: 4 O O 3.1415'x 3.0'x 3.0'x 1'x 62.4 Ibs./cu.ft. = 1764.3 Ibs. NOTES: N MAX. DISPLACEMENT = 95.4 — 93.4 = 2.0' MAX. UPLIFT PRESSURE = 2.0' X 1764.3 Ibs/ft = 3528.6 lbs. 1. PUMP CHAMBER SHOWN IS AS MANUFACTURED BY ACME—SHOREY N WEIGHT OF UNIT EMPTY = 11,795 lbs. (INCLUDING TOP) PRECAST CO., 36 GREAT WESTERN RD, HARWICH, MA 02645 t; •C;..::;:,'.»'::,' ,: 11,795 Ibs > 3529 Ibs O.K. 4 H-20 PRECAST 500 GALLON PUMP CHAMBER SECTION PLAN DOSING 8c STORAGE REQUIREMENTS ACME SHOREY PRECAST CORP D136 DESIGN FLOW: 330 GPD N.T.S. DOSING REQUIRED: 6 CYCLES/DAY(MIN. RECOMMENDED BY PRESBY) 330 _ 6 = 55 GALLONS/CYCLE SPECIFICATIONS DISTANCE REQUIRED BETWEEN PUMP PROPOSED SEPTIC SYSTEM UPGRADE PLAN 1.) CONCRETE STRENGTH 4,000 PSI ®28 DAYS. ON AND PUMP OFF FLOATS: 46 SIERRA WAY, SOUTH YARMOUTH, MA 2.) STEEL REINFORCEMENT PER AS -615-68, GRADE 60. 55 GAL/CYCLE - 147 GAL/FT = 0.37 FT/CYCLE (SAY 4") 3.) DESIGN LOADING PER AASHTO H-20 MEETS ASTM SPEC. C1227. STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: Prepared for: D.A. Brown, Inc. P.O. Box 145, Centerville, MA INV.(IN) EL: 97.48 — PUMP ON EL: 95.06 = 2.42' Engineering by: Surveying by: SCALE DRAWN JOB. NO. STORAGE PROVIDED = 2.42' x 147 GAL/FT = 355.7 GALLONS Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 175-15 DISTRIBUTION BOX 12 West Crossfield Road 2854 Cranberry Hwy. Forestdole, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET N0. (508) 477-5313 (508) 273-0377 8/31/15 P.T.M. 3 Of 3