Loading...
HomeMy WebLinkAbout9 Doves Wing Road Proposed Septic DesignSOIL TEST DATE OF SOIL TEST SEPTEMBER 13 2005 SOIL TEST DONE BY SW'EET5_ER�INE RING WITNESSED BY A. VON HONE_= SERVATION HOLE 1 ELEV.= 31.3 OBSERVATION HOLE 2 ELEV.= 30.9 PERCOLATION RATE < 2 MIN./INCH AT 108 INCHES DEPTH HORIZ I TEXTURE COLOR MOTT. OTHER MOTT. 0 6' A LOAMY SAND 10YR6/1 NO ROOTS SAND 6x29' B LOAMY SAND t0YR6/4 B 2r-96" Cl MEDIUM SAND 2.5Y7/3 SWEMM? UENG ROADFJ 508- P. 0. BOX 713 385-6900 SOUTH DENNIS, MASS. 02660 G-1" 9 20 C2 LOAMY SAND 10YR8/2 - VERY SILTY 2.5Y7/3 TOP OF FOUNDATION ELEV. = 35.OG DEPTH HORIZ I TEXTURE COLOR MOTT. OTHER 0-8" A LOAMY SAND 10YR6/1 NO ROOTS 8-25" B LOAMY SAND 10YR6/4 SWEMM? UENG ROADFJ 508- P. 0. BOX 713 385-6900 SOUTH DENNIS, MASS. 02660 25-57" Cl MEDIUM SAND 2.5Y7/3 scALe 1" = 20' 57-84" C2 LOAMY SAND 10YR8/2 VERIGATED 84-144" C3 MEDIUM SAND 2.5Y7/4 44" C3 MEDIUM SAND 2.5Y7/2 NO WATER ENCOUNTERED AT 144" ELEV. m 18.9 VATER ENCOUNTERED AT 144' ELEV. 19.3 // I I � 1 3112 6Bsg. / I 311`. 1 • Io• 35.0 I I I27 32.8 UFO (0 I �0 O II ); I II .9 Lit l5, 1.6 1 \ of \�30. A I • 32.9 52. 7�, 3.75 SLAB ELEV. = 10 FT. MINIMUM 24' MANHOLE COVER 4" CAST IRON PIPE (OR _QUAL) MINIMUM PITCH 1/4" PER FT. -ELEV. EL EV. 1 l 33.0 ` EwAGE IIMUM FROM CELLAR OR CRAWL SPACE 10 FT. MINIML!M FROM SLAB -SINGULAIR () 24" MANHOLE TREATMENT /MODEL 960 ON PLANT COVERS /�4 SCHEDULE 40 PVC PIPE / \ MIN. PITCH 1/8" PER FT. TEE 432.75MA N SAND INSPECTION PORT LOAM AND SEED 2" LAYER OF 1/8' TO 1/2" WASHED STONI OR FILTER FAE 30.50 MIN. z29.75 T7 v, VENT NOT REQUIRED ❑❑❑❑❑O❑❑❑❑❑ 0 0 T2' 10'� 2'D" MIN. LEVEL o °ELEV. = 6" SUMP -ELEV. _ _29•� DISTRIBUTION ELEV. o°° ❑❑ ❑❑❑❑❑❑ ❑❑❑ 27.00_ _ (TO BE P4ACED ON FIRM BASE) BOX 2 500 GALLON GALLEYS WITH SINGU IR TREATMENT (TO BE WATER TESTED) STONE IN AN PLANT 13' X 25 X 2' TRENCH FORMATION 9 14,70 SAMPLE CATCH AND 3/4" B EO WASHED STONE SOIL ABSORPTION to RECIRCULATING PUMP FREE OF FINES & SILT SYSTEM SAS SQOSAL ISYSTEM PROFILE OBSERVED PROBABLE WATER TABLE ELEV. _ 230 1 NOT T SCALE OBSERVED WATER TABLE (9/13/05) ELEV. = - 9.50 _ TEST HOLE 2, LOT 9 BOTTOM OF TEST HOLE ELEV. - 38.9 WELL A1W 230 DESIGN CALCULATIONS ZONE C NUMBER OF BEDROOMS 3 INDEX 23.3 GARBAGE DISPOSAL UNIT __FTtf ADJUST_ TOTAL ESTIMATED FLOW ( 110 GAL./BR./DAY X _1_ BR.) _0_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY _1485._ GAL. ACTUAL SIZE OF SEPTIC TANK 1500 GAL. SOIL CLASSIFICATION DESIGN PERCOLATION RATE SteMIN./IN. EFFLUENT LOADING RATE D,74_ GAL./DAY/S.F. >3 O' LEACHING AREA 477.00 SQ. FT. SOIL <. (13X25)+(38X2X2) 1 TEST - LEACHING CAPACITY (AREA X RATE) -35MB GAL./DAY SAMPLE% 477.00 X 0.74 CATCH D. u / RESERVE LEACHING CAPACITY 352.8@ GAL./DAY Box o NOTES: SINGULAIR TREATMEN' 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2 /1 / / 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. F ( 3. Al_'_ COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF 1^ \ \ WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN ;0 FT. OF DRIVES OR PARKING AREAS. H-20.LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. Ln , .4 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL ryy ` 1 1 BE MORTARED IN PLACE. _ / m 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH • 30.6 1 / �_ DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO PORCH ' m. a, (NOV) _, N \ N PROPOSE WELLING i 6 J OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. n1 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR- tS-T"ERIFY`CRADES-AND-ELEVATIONS-AS-WELL -AS SITE - N - CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO 3 BEDH�JO S ` ! BE BROUGHT TO THE ATTENTION QF THE DESIGN ENGINEER IMMEDIATELY. 'I I 3.0 �(32)_ _ _ 1 8. PARCEL IS IN FLOOD ZONE ___ ! 1 9. LOT IS SHOWN ON ASSESSORS MAP �� _ AS PARCEL10 (J �' _ 10 10. THE INSTALLER IS TO GIVE THE ENGINEER, A MINIMUM OF 48 HOURS EXJ,5 TING yid/ 1 _ CO/ /HIDA T/OnI 1 \ $$ p �- --- L 1-? I �.• tyI OF MAS (2 WORKING DAYS) NOTICE FOR THE FINAL INSPECTION (NUMBER BELOW). / CJ(V \ \ \ 1 LOT 15 t 11. A VARIANCE OF 6.5' IS REQUIRED FOR THE TOP OF FOUNDATION TO BE S �� LESS THAN 2' ABOVE THE HIGH POINT IN ROAD (NON -ACCESS WEST 19, 650 f S F. r c . rCI =° T M GREAT WESTERN ROAD). 38.3 �'� I ° 38.3 �� G 1 v" H u L _ y1vJ R .97 / APPROVED: BOARD OF H DECK 1 / \ 37.5 C.[ 1 - MITA 38.133.6 o _ \' D. CATCH PLE• 351NG IR 9T ✓.� \ BOX TREAIL T PLANT \ SOIL VA , RESERVE SAS TEST 1 \ \\ \� �0% 16 M r! \ \ 21, 302 S F. J V=NT_= =00 / \ $TEST 2 \' \} 36.6 \\� r 37.9 uOVERDIG • 42.7 I _X38.9 IER /JCpQ' ` 42.0 LEGEND: / / -Z_ EXISTI P sav Et wrroN 00"0 1i � ` EXIS NG CONTOUR ----00---- / _� L- 142 BB FINA64SPOT ELEVATION D0.0 FINALCBNT@lt00 VJ/ I j »-4&3- 10= ccs` n,i£kv" SOIL TEST LOCATION i® _ ,, C UTILITY POLE �TEQn / / (N,'w TOWN WATER -W�W CATCH BASIN GAS LINE 4l fL l CLEAN OUT -^C.O. - -� DATE AGENT® 04 _ ?O✓l6250-001d»g 16250-00SASDWG 02009 SWEETSER ENGINEERING LOCUS ?LOC. G 7 N Oki T �FSTF ROUZE 6 PROPOSED SEPTIC DE NQ FOR -' DAVCO BUILDERS, ` _ LOT 15 - 9 DOVE'S WING ROAD, ';YARMOUTH SWEMM? UENG ROADFJ 508- P. 0. BOX 713 385-6900 SOUTH DENNIS, MASS. 02660 DATE NOV. 17, 2009 scALe 1" = 20' REv. DEC. 14, 2009 F7e No. 6250-15 LOCATION MAP i REV. SHEET 1 OF 1 ?O✓l6250-001d»g 16250-00SASDWG 02009 SWEETSER ENGINEERING