Loading...
HomeMy WebLinkAbout3 Doherty Lane First Floor Plan1 A A.6 �a RELOCATED rKW (V HOT WATER 1 — xQ NEW 3 1/2" GONG. FILLED I 'v3 STL. LALLY COLUMN I I m3 ON 36"x120"x12" DP.- iZ GONG. FOOTING, TYP. I M, I IL m� 3-1 3/4" x 11 7/8" LVL ( l i n (NEW DROPPED BEAMrI n GARAGE _ n m 3 -10 L-- (NEW/HEADER ABOVE) m NEW CO'y SHOWER 0 Q --------------- IF — -------- ------- ® 16" O.C. UNLESS OTHERWISE NOTED. �I �I 2. ALL INTERIOR WALLS SHALL BE 2X4 NEW ® 16 O.C. UNLESS OTHERWISE NOTED. L RAISED sl 3. CONTRACTOR SHALL VERIFY ALL WINDOW ROUGH OPENINGS PRIOR TO ORDERING WINDOWS. - 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PAT 10 I _ � ASSUMES RESPONSIBILITY FOR ANY MISSING OR I I �I 2-1 3/4" x 11 7/8" L L to x 11 7/8" LVL (NEW HEADER ABOV ) El^LFiEADER ABOVE) 17 FWG12068-4 II �I _ I 2 �b1 21I-1 /4" x 11 7/8" LVL (NE DROPPED BEAM) I 'T - KITCHEN _y o III DINING —��a ' ROOM V oe _ O O3 ARCHED CASED OPENING W/ - Q =1 KEYSTONE �i Lfn o L m .mo N fn NEW i'-6"xt'-6" ri� 4 DUCT. CHASE 10" SQUARE COLUMNS TYP. �ON CAPPED KNEWWAL NEW RAIL G (® STAIR L COVERED— I I ^II 2-1 3/4" x 11 7/8" LVL (NEW ROPPED BEAM) =1 RST 1= LOO INS �I II I� II I I I I I L----------- J LAN p1-41 THIS BUILDING IS DESIGNED IN ACCORDANCE NITP TPE MASSACPUSETTS STATE BUILDING CODE Sth EDITION. TPIS INCLUDES THE HIND LOAD FOR EXPOSURE C AND 110 mph. LIVING ROOT" I 2-1 3/4" x 14" LVL (ABOVE) 10" DIA. COLUNM NOTE: ALL NINDOWS ARE TO BE ANDERSEN 400 SERIES WDH N/ APPLIED GRILLES INSIDE AND OUTSIDE WALL KEY EXISTING WALLS [ _ _ _ _ _ ] WALLS TO BE REMOVED ® PROPOSED WALLS z Q Q (n z O W w x Q w 1' U W S U w x LU V)<Q >W�2o W�cn Zo (n az¢wjz,,-z5� W J U a Z W O �.>cnoow Jaz mowoExmzL Uo O wp x w r - w �z �r- cn r- cn _ S wi-�wOmq w C.� pW=m O K�NZ O 1- T: OZ�OUJO UJOU d cnCI- r-¢ofP:n.oM O o W O O m 0 x Z w U Z K U Z O L si- w Q o u n0 >� Fn 1Om W V1 SON -- -!!:4 of o cj Q-�) 5 a O o ~ c;d 0 H w ' w Wo � NN w > z_ o U an Z� 1j 'N 0 ;oNmo m� 0 5; 0 � w �Z�OOJZ=UO¢N]z0 F6�yiZ UOriUU \J z�VaV�fvNio�zo z Z> J OO FI -N UK U o z Z N U w w Wy� N 0 0 0 m Z K of 3 zQ w a_ a A N O = W N d a UUl O Q m w _= O z� K U 92 0 0 wzffiW 0 a>m�aff�;wio�wmazw"� awL^ zNW� gwaw oo �no�aS�dmawoa���mwa Q z Q W O w�O3 w(yzzo � ll.jQE LLI LL L ( Q3 Ar- (f)w w O b CIL N� L o oZ Ll z O Z H a N DO Z o l oz 0 Z V W z � Q d O_ d co O U OL (n U) O O J Q Of Zui m M 0:2 U Z) z 1. ALL EXTERIOR WALLS SHALL BE 2X6 p ® 16" O.C. UNLESS OTHERWISE NOTED. 2. ALL INTERIOR WALLS SHALL BE 2X4 ® 16 O.C. UNLESS OTHERWISE NOTED. sl 3. CONTRACTOR SHALL VERIFY ALL WINDOW ROUGH OPENINGS PRIOR TO ORDERING WINDOWS. 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. CONTRACTOR ASSUMES RESPONSIBILITY FOR ANY MISSING OR INCORRECT DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER. to O z 1- W w S