HomeMy WebLinkAboutReview Checklist �=�'r�
TOWN OF YARMOUTH
, SEWAGE PLAN REVIEW CAECKLIST i
� Location: A.M. /Z� Lot �� Zone af Contribution: In Out� Acreage
/' Commercial: Residential: ���
�` Street: [--�l�L�
Village: Floor Plan: ��' #Bedrooms: � ;
Owner: vL.P Installer:
� �
Address: �� Phone: ��
Phone: ���� j �
Builder: Engineer: �
Address: Phone: " -
Phone: �- �yr ��!�lA��� " -D�S �'�"ti� ���
s l�..e�" �
N/A S NO
1.Required#of copies received
2.Date of soils exam and ercolation test not older than 2 ears
3.4-5 ft of naturall occurrin ervious material, above water table
4.Founda.tion 2 ft above high oint of road H.P.: Fnd: Var.:
5.Water line 10 ft from s tic com onents Var.: '�--�
6.Benchmark indica.ted and shown-NGVD if near wetlands
7. S tic tank minimum 10 ft from foundation, deck Var.: ✓�
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: l'_/
9.Leachin minimum 100 ft from wetlands Var.: •
10.Leachin minimum 150 ft from drinkin welU25 ft irrigation well Var.: -----�
11.Tank/leachin minimum 10 ft from ro line Var.:
12. S stem meets all other setback r uirements Var.: E,.-�
13.Uses ad"ustment for maximum high oundwater Var.: -
14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: �-�
15. S stem not in to or subsoil(A,B horizons)or 5'removal
16.Pro osed contours are suitable � � - y
17. S stem meets slo e r uirements-min. 1/8", 1/4" referred �/
18. S stem meets breakout requirements PVC liner: Wall:
: 19.S ecified tee sizes are roper, gas baffle on outlet tee �--�
20. Sewa e is under 10,000 gpd for parcel L/
21.No ba e dis osal "
�� 22. S stem ad ua.tel sized for its intended use `--''
23.Minimum 6"stone or com acted below tank and dbox
24.Manhole covers withi.n 6"of ade, um chamber cover to grade �--'�
25.Ins ection ort on plastic chamberslleach field �_�
26.Electrical ermit for um chamber/S arate meter for du lexes --�'
27.Pum system-2" line,wee hole,ch�k valve,tee in dbo� um size ��
28.S tic tank/pump chamber to be facto wat roofed ��
29.Vent rovided if leaching below 3 feet,under driveway/ arking �
30.Buoyanc calculations for tank/ ump chamber
31.En ' eer to ins ect and c ' soils: wall: commercial:
32.En ' eer/Re ' tered Sanitarian and Land Surveyor stam s/signature �---
33.H-20 loadin is subject to vehicular traffic, oundwater �---�
34.Title V A lication and ermit fee, insta.11er si ture -
35.Foundation footing min. 2 feet above ad'usted ound water for new house
36.Deed Restriction r ired max. #bedrooms: max. flow: d -�'"
37.Check area lots for oundwater/Label oundwater in Assessor's Ma
Plan reviewed by: �-' �o3io�