Loading...
HomeMy WebLinkAboutReview Checklist �=�'r� TOWN OF YARMOUTH , SEWAGE PLAN REVIEW CAECKLIST i � Location: A.M. /Z� Lot �� Zone af Contribution: In Out� Acreage /' Commercial: Residential: ��� �` Street: [--�l�L� Village: Floor Plan: ��' #Bedrooms: � ; Owner: vL.P Installer: � � Address: �� Phone: �� Phone: ���� j � Builder: Engineer: � Address: Phone: " - Phone: �- �yr ��!�lA��� " -D�S �'�"ti� ��� s l�..e�" � N/A S NO 1.Required#of copies received 2.Date of soils exam and ercolation test not older than 2 ears 3.4-5 ft of naturall occurrin ervious material, above water table 4.Founda.tion 2 ft above high oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: '�--� 6.Benchmark indica.ted and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, deck Var.: ✓� 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: l'_/ 9.Leachin minimum 100 ft from wetlands Var.: • 10.Leachin minimum 150 ft from drinkin welU25 ft irrigation well Var.: -----� 11.Tank/leachin minimum 10 ft from ro line Var.: 12. S stem meets all other setback r uirements Var.: E,.-� 13.Uses ad"ustment for maximum high oundwater Var.: - 14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: �-� 15. S stem not in to or subsoil(A,B horizons)or 5'removal 16.Pro osed contours are suitable � � - y 17. S stem meets slo e r uirements-min. 1/8", 1/4" referred �/ 18. S stem meets breakout requirements PVC liner: Wall: : 19.S ecified tee sizes are roper, gas baffle on outlet tee �--� 20. Sewa e is under 10,000 gpd for parcel L/ 21.No ba e dis osal " �� 22. S stem ad ua.tel sized for its intended use `--'' 23.Minimum 6"stone or com acted below tank and dbox 24.Manhole covers withi.n 6"of ade, um chamber cover to grade �--'� 25.Ins ection ort on plastic chamberslleach field �_� 26.Electrical ermit for um chamber/S arate meter for du lexes --�' 27.Pum system-2" line,wee hole,ch�k valve,tee in dbo� um size �� 28.S tic tank/pump chamber to be facto wat roofed �� 29.Vent rovided if leaching below 3 feet,under driveway/ arking � 30.Buoyanc calculations for tank/ ump chamber 31.En ' eer to ins ect and c ' soils: wall: commercial: 32.En ' eer/Re ' tered Sanitarian and Land Surveyor stam s/signature �--- 33.H-20 loadin is subject to vehicular traffic, oundwater �---� 34.Title V A lication and ermit fee, insta.11er si ture - 35.Foundation footing min. 2 feet above ad'usted ound water for new house 36.Deed Restriction r ired max. #bedrooms: max. flow: d -�'" 37.Check area lots for oundwater/Label oundwater in Assessor's Ma Plan reviewed by: �-' �o3io�