Loading...
HomeMy WebLinkAbout144 Driftwood Lane - Site Plan of Land/ ACCESS COVERS MUST BE WITHIN 6 of FINISH sH GRADE 9' M!NIMU'd. INVERT ELEVATIONS. • DES I GId `CR l TERIA: A GEN T GENERAL NOTES: 3 :MAXIMUM COVER ,NO .' 107.0 FIRST 2' TO INVERT AT, BUILDING: 103.0 ' DESIGN FLOW: LEVEL MIN 2' OF PA5TONER IN SEPITAN . 7NVBEDROOMS ror.sBf 4 A7 I10 G.P.D.. .. PER 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION r /�u I / INVERT OUT SEPTIC TANK: 101.25 BEDROOM EOUALS 44 0 G.P.O. OF THE SEWAGE DISPOSAL SYSTEM ONLY. Y. / 3/4' - t 112' DIA, INVERT IN DIST. BOX: 100.77' 3 =� 100.6 � ?' ° � DOUBLE WASHED STONE INVERT OUT DIST. BOX. "700:6: NO GARBAGE GRINDER 2. VERTICAL DATUM 1S ASSUMED. FOR BEACH MARKS ' ! ! uAs 100.5 9 5 INVERT IN LEACH CHAMBER: 100:5 SET. SEE SITE PLAN. PAFFtE SEPTIC TANK REQUIRED: s S r 3-.,00 A 3 OUTLET GAL LEACHING CHAMBERS r :BOTTOM OF LEACH CHAMBER. C 98:5 440 G.P.D. X O z - 2 0 880 A GAL. 3, '. ALL CONSTRUCTION M ETHODS AN ' D MATERIA LS AND r W/4' STONE AR - X E OUND: -080 GAL- I2.8'• x 33.5' x 1 2'd ADJUSTED GROUND WAT U D ER: - N/A SEPTIC TANK PROVIDED: 1500 GAL: MIN, MAINTENANCE OF THE SEPTIC SYSTEM SHALL PTI TAN SE K 6' CRUSHED STONE OR OBSERVED GROUND WATER: N/A CONFORM TO MASS - . D.E.P.TIC TITLE 5 AND LOCAL COMPACTED BASE M • : SOTTO OF TEST HOLE 2 88.4 SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. DESIGN PERC RATE C 5 MIN/INCH PROF I L E •NOT TO SCALE SOIL'TEXTURA `C - L LASS l 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE -.0.74 GPD/SF AREAS SUBJECT TO VEHICULAR. TRAFFIC OR GREATER 440 GPD / 0.74 GPD/SF - 595 S.F. RERUIRED THAN 3' ,N DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PROVIDED: 3-500 GAL LEACHING CHAMBERS SM. CB/DHFND W/4'STONE AROUND., A-614 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR EL -112.41 614 S.F. x 0.74 - 454 G.P.D. APPROVED EOUAL. N SO IL rEsr Pt r DArA® 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED .PRECAST CONCRETE AND M'ATfRTlGHT; D -BOX SHALL INDICATES 7 :INDICATES BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE PERCOLATION : = OBSERVED IS MORE THAN ONE OUTLET. 662255 TEST _ ' GROUNDWATER TP •1 TP 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'.; 02: 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. HORIZON TEXTURE 0" COLORHORIZON TEXTURE COLOR FOR LOCATION.OF UNDERGROUND UTILITIES, _ 102.5 0* 100:4 A SANDY IOYR SANDY IOYR 4 LOAM 3/2 LOAM ALL UNSUITABLE MATERIAL (A a HORIZONS) .... . :.. :.. .......:.:... /02..0-..6. - ... .... ..:...... ...: ..:...... 99.9 ENCOUNTERED BELOW THE INVERT OFTHE..:... THE LEACHING. LOAMY O B IOYR LOAMY IOYR 8 FACILITY TO BE REMOVED FOR -A DISTANCE OF ,5' SAND 6/6 "SAND 6/6 ` AROUND AND REPLACED WITH SAND IN ACCORDANCE 36• ..::..:. ....:.::: .:::............:. 99.5 48' .::.. .....:: , :....:.. ......:.. 96.'4 W WITH TITLE 5: C I MEDIUM 2.5Y MEDIUM 2.5Y, l . j SAND 7/3 SAND 7/3 9. NO DETERMINATION HAS'BEEN MADE AS TO ' COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY 70 OBTAIN ALL PERMITS. SPECIAL 96 .... ........: . .................. 94.5 96 92:4 . PERMITS. VARIANCES ETC. FOR THIS PROJECT. C2 LOAMY 2.5Y C2 LOAMY 2.5Y SAND 7/1 SAND 7/2 !0. IT SHALL REMAIN THECL lEN7 S RESPONSIBILITY - FIRM FIRM TO HAVE THE PROPOSED BUILDING FOUNDATION . -. ' DESIGNED TO ACCOUNT FOR THE EXISTING GRADE 1 \ •.`< -<\ 1t \ -_ - 150' _NO WATER -F 90.0 144' NO WATER - 86.4 AND :SOIL CONDITIONS AT THE LOCATION OF THE - lI PROPOSED BUILDING. DATE: MAY 22. 2003 TEST BY. DANIEL OJALA WITNESSED BY: AMY VONHONE PERC RATE: f 2 MIN/INCH - Gs�.y6. CATCH BASIN REDrRECT SHALE