Loading...
HomeMy WebLinkAbout144 Driftwood Lane - Site Plan 2., ACCESS COVERS MUST BE IftTHIN 1., 9 MINIMUM, I N VER T EL E VA T 1 ONS : DE S l GN R l TER IA: A: GENERA L NO TES 6' OF FINISH GRADE r F 2' 3' MAXIMUM COVER DESIGN ` RL 107,0 FIRST INVERT AT BUILDING: 103.0 FLOW /// TO E rr LJ C 8E LEVEL INVERT 1N SEPTIC TANK: 101.5 4 BEDROOMS AT IID G.P.D. PER 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION ;, MIN 2' OF PEASTONE FDccrrs I r - INVERT OUT SEPTIC TANK: 101.25 BEDROOM EQUALS 440 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. POND ! nIAM PrP - 3/4" - 1 1/2- D/A. N ARB GRINDER -J INVERT /N DIST. 80X: 100. 7T v o c INVERT OUT DIST. 80 III0.6 2. VERSET. CAL SEE S�TEkPLANIS ASS ��L_p3`O /pp,6 {k62. DOUBLE' WASHED STONE 0 GARBAGE oR/ Cr - y < GAS v $ �$ 98.5 INVERT IN LEACH CHAMBER: 100.5 SEPTIC TANK REQUIRED., ASSUMED. FOR BENCH MARKS S,!!TPK l pl. BAFFLE 1_O.1J .1' IOD. S BOTTOM OF Lc'ACH CHAMBER: 98.5 FzqN L{�TUS``, " OUTLET 3-500 GAL LEACHING CHAMBERS 440 G.P.D. X POOx - 880 GAL. J. ALL CONSTRUCTION METHODS AND MATERIALS AND D-BOX W/4' STO.N'E AROUND. 12.8'■ x 33.5'1 x 2'd ADJUSTED GROUND WATER: N/A SEPTIC TANK PROVIDED: 1500 GAL. MIN. MAINTENANCE OF, THE SEPTIC SYSTEM SHALL y I 500 GAL OBSERVED GROUND WATER: N/A c i CONFORM TO MASS.' D.E.P. :TITLE SAND LOCAL o SEPTIC TANK6- CRUSHED STONE OR � BOTTOM OF TEST HOLE 02= 88.4 SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. COMPACTED BASE v ` DESIGN PERC RATE f 5 MIN/INCH q ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER i PROF I L E :NOT TO SCALL SOIL TEXTURAL CLASS = 1 AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF 595 S. F, REQUIRED THAN v" IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL'LOADS. •. PROVIDED; 3-500 GAL LEACHING CHAMBERS L O��C VIA P BM. CBiDHFND W/4' STONE AROUND. A-614 S.F. - 5.. ALL SEWER PIPE' SHALL BE SCHEDULE 40 OR L J JVIH APPROVED EQUAL. EL-trz.4r 7 6f4 S, F: x 0.74 - 454 G. P, D. �J 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED j y SO /L TES T P / T DA:TAs PRECASTCONCRETE AND WATERTIGHT: D-BOX'SHALL �I INDICATES 7_ INDICATES BE WATER TESTED TO CHECK FOR LEVEL WHEN'THERE �Q PERCOLATION OBSERVED 15 MOPE THAN ONE' OUTLET. SSB TEST GROUNDWATER 7. BEFORE CONSTRUCTION CALL 'DIG-SAFE' TP #I TP #2 1-888-DIG-SAFE AND THE LOCAL WATER DEPT, HORIZON TEXTURE COLORHORIZtlN TEXTURE COLOR FOR LOCATION OF UNDERGROUND UTILITIES. / 0' 102.5 0' 100.4 i / Q SANDY IOYR A' SANDY IOYR 8, ALL UNSUITABLE MATERIAL (A d B HORIZONS; LOAM 3/2 LOAM 3/2 ENCOUNTERED BELOW THE •INVERT OF THE LEACHING 6 102.0 6' ........ 99.9 FACILITY TO BE REMOVED FOR A DISTANCE Ofi;S' / 8 LDAMY IOYR SA N4 6/6 SAND 6/6 LOAMY IOYR AROUND AND REPLACED WITH SAND IN ACCORDANCE 36• ........._,._...._.. ......._... 99.5- 48"-......... ....... ..... .... 96..4 WITH TITLE 5. I C' MEDIUM 2-5Y/ 0E0IUb1 2.5Y - SAND 7/3 SAND 7f3 9. NO,DETERMINATION HAS BEEN'MADE AS` TO i - 60- COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONS IL) TY TO I TS., SPECIAL 96- .... ... ...... _ ... 94.5 96' 92.4 PERMITS'BOBTAIN VARIANCES ETC.FORITHISML PROJECT. C2 LOAMY 2.5Y C2 LOAMY 2:5Y SAND 7/2 SAND 7/2 /0. IT SHALL REMAIN,THE CLIENT'S RESPONSIBILITY FIRM FIRM TO HAVE THE PROPOSED BUILDING FOUNDATION' T�FifL' jI - OESIGNED`TO ACCOUNT FOR'THE EXISTING GRADE / 1S0NO NATER 90.0 144' 88.4 I NO WATER AND SOIL CONDITIONS AT THE LOCATION OF THE / " PROPOSED BUILDING., DATE: MAY 22. 2003 TEST BY: DANIEL OJALA L / WITNESSED BY. AMY VONHONE PERC RATE: ( 2 MIN/INCH ' cp , .. _ qa i CATCH BASIN RIM-103.86 -i 'y REDIRECT SWAL£ d - l Lwr , ' `•, < <; _ LOT 1 `'' ,' '.,, /� r---IID"5 \og � \ ' , Q�yo•, �l �c•cf'�.. t �y� RAYf'.o(� ,� � bd, 0� `� - pG 40.288± S.F. UPLAND 288' S.F. WETLAND 5 iP r 0 0 "coPo 40.576* S.F. TOTAL 3-500 GALLON . _. ,, 2, _ _. _ ✓ // �ti0 � LEACHING CHAMBE r F14' STONE AROUND .. 13. 1.400 GALLON L. $O REMQVAL h �1 'SEPTIC TANK / h ; . r r _ - - SEE T{' 8. �� � D- BOX _.... _ y t! ' •. -GUY WIRE TPO i GUY POLEQ/ N BM. CB OH FNA / EL-1019.4) DMNm ,,✓ 38 .00. / 7EPL ,moi /V OF L A IVO 4-4 O RTWO0 0 L ,4 /V ,4 . .3 / Ic E M P / 2 8. P.�i R CEL /� PREPARED FDR ` CATCH BASIN OA V LD /V / (�_:7 \.../ L 4-- HA/VOREN BROS P . Q. SOX /0. "ARV'✓l CH "A 02645 -�� SCAL E ' / " -, 20 A1J(3tJS T / / - 200.3 �rl ' EA0L_E SURVEY f NO, { N w yt i %yam �xk 923 Route 6A Yarrnouthport MA. 026-76 362-8132 op 3/Q3 C�GGc.�.. �t�'+!, � { 508 ) . 432-5.333 0 !0 20 40: JOB NO 03-060 FIELD,;.CFW/DAE CALC. SAN GNECK CFW , DRN: SAfd