HomeMy WebLinkAboutEngineered Plans - 2015SITE LOCUS: 199 S Sea Ave q _ PROJECT BENCH MARK---,,, TOP OF FOUNDATION ELEV. = 100.00 (ASSUMED) l Bath Bed Breezeway Bed Room Kitchen Room Living Room c Nook Breakfast GARAGE � Bed Room Dining Room r l\e 0 NIP H FAILEDPIT PATIO SLAB FOUNDATI EXIST. 'l 1000 g Sept Tank EXISTING 3 BEDROOM HOUSE #199 FULL FOUNDATION e9� l Bath Bed Breezeway Bed Room Kitchen Room Living Room c Nook Breakfast GARAGE � Bed Room Dining Room r l\e 0 NIP H FAILEDPIT PATIO SLAB FOUNDATI EXIST. 'l 1000 g Sept Tank EXISTING 3 BEDROOM HOUSE #199 FULL FOUNDATION GARAGE SLAB FOUND TIO \ I ,i \ ASPHALT DRIVEWAY Nitzt7" \ � Gravel/DirtVENT' / IVEWAY PIPE ) y �i 05 \ TEST HOLE #1 SEWER LINE TO BE DOUBLE SLEEVE'R j ELEV.= 99.50 WITH 6" SCH 40 PVC PIPE 10' EITHER SIDE OF WATER LINE 4o OF SEPTIC SYS7 t D -Box Periart valid for REPAIR � � \ \ �.. ONLY due to Stale and Local septic variances Board of Wan review and approval is required for % 4-�' any„ future additions/renovations/alterations to sewage facilities airdlor struetilreshiwellingr i Yarmouth E4ealth Ikpa-rtment �'�� ®\ L = 37.62" \ Catch Basin R = 20.00 ® f CJQ�.. _. _._. / 0 20 40 50 k 1. REQUEST A VARIANCE TO REDUCE GROUNDWATER ADJUSTMENT BY 1'. VARIANCE WILL ALLOW FOR 1' REDUCTION FROM 5' to 4' FROM Bottom of SAS to SCALE: 1 "=20' FA GENERAL NOTES 1. Contractor is responsible for Digsafe notification, Verification of Utilities and protection of all underground utilities and pipes. 2. The septic tank oncdistri ution box shall be set level on 6 of 3/4'-1 12' stone. 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Carmen E. Shay - Environmental Services, Inc. 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and Local Regulations. 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in our design installation must halt & immediate notification be made to Carmen E. Shay - Environmental Services, Inc. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install Tuf-Tite gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is Connected to ALL OF The Residence and Abutting Properties Within 150 Feet. THE PROPERTY LINES ARE APPROXIMATE AND �1(y) COMPILED FROM THE DEED DESCRIPTION BOOK 5709 PAGE138 AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN IT SHOULD BE USED FOR NO PURPOSE OTHER THAN THE SEPTIC SYSTEM INSTALLATION. EXISTING LEACH PIT TO BE PUMPED OUT AND FILLED IN PLACE NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FROM THE EXISTING CESSPOOL/LEACH PIT TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. REV: 4/13/15 - per AHV REVIEW PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR ELAINE STULIC AT c 199 SOUTH SEA AVENUE ? { ASSESSORS MAP 17, PARCEL 99 YARMOUTH, MA PREPARED BY: t ` CARHEY E. SHAY !ENVIRONMENTAL SERVICES f P.O. Box 1576 MASHPEE, MA 02649 TEL/FAX : 508-294-7498 SCALE: 1 "=20' DRAWN BY: CES PROJECT#SD2024 FILENAME: SD2024PP.DW DATE: MARCH 24, 2015 SHEET 1 OF 2 *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. 10' min. from— Existing rom--»Existing Foundation house to septic tank BASEMENT FLOOR SLAB = ELEV. 100.00 EXIST. PIPE FROM EXIST. FOUNDATION compacted stone I NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN 6" BELOW GRADE SYSTEM PROFILE Not to Scale E Ml STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3-24" REMOVABLE COVERS li t }__t2�--_��min. L quid levlinlet to outlet 6. n III�� 10" min. ' ( e f ,,.T 5' —7" OUTLET THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SET DEEPER THAN 6 INCHES BELOW FINISHED GRADE SHALL BE RAISED TO WITHIN 6" OF FINISHED GRADE. INSTALL TUF—TITE GAS BAFFLES OR EQUALS 13" INLET "r %,• • 5' —7" 4'-0" min. • Liquid depth 6.-0" 1 4' —10" CROSS SECTION END—SECTION TYPICAL 1000 GALLON SEPTIC TANK NOT TO SCALE Design Calculations Number of Bedrooms: 3 Equivalent to 330 Gal./Day Garbage Grinder: No Leaching Capacity Proposed: 330 Gal./Doy Minimum (Min. Per Title V) Septic Tank : — 2 x 330 Gal./Day = 660 USE NEW 1,000 GAL. Septic Tonk. SOIL ABSORPTION AREA: Using percolation rate of CL min./inch Bottom Area: 0.74 gat/sq. ft. x 450 sq. ft. = 333 gallons per day SidewaN Area: NOT USED Providing: = 333 gallons per day SOIL ABSORPTION AREA: Using percolation rate of < 2 min./inch Proposed Leaching Field Dimensions: 1 ® 15' Wide by 30' Long. Bottom Area: 0.74 gat/sq. ft. x 450 sq. ft. = 333 gallons Sidewoll Area: Not Utilized Providing: = 333 gallons ((0 Least 24 inches tall) 40 PVC w/Charcoat Odor Fitter 2'-6" I Sch. 40 — 4" TOP OF Leoch Field - 96.00 3"-1/8"-1/2" Washed Stone ,n" 5'-0" on center 2"-1/8"-1/2" Facility Elev.- 94.68 ADJ. GROUNDWATER = 1.6' or ELEV 90.68 Bottom of Test Hole 1 Elev.=88.50 Groundwater Observed — 125" or Elev-89.08 PERCOLATION TEST Date of Percolation Test: February 11, 2015 Test Performed By: CARMEN E. SHAY, R.S., C.S.E. lesults Witnessed By: AMY VON HONE—YARMOUTH BOH EXCAVATOR: Shay Env. Sycs. Percolation Rate: Less Than 2 MPI ® 66" i Test Hole No. 1 i i DEPTH SOILS ELEV. 0 99.50; Loamy Sond 10 YR 3/2 0"— 8" A' Loamy Sand 10 YR 5/6 8"— 36" Bw 96.50; Med. Sand 2.5 Y 7/4 36"— 13 Perc #1 Depth to Perc: 44" to 66" Perc Rate= 2 MPI Groundwater Observed ® 125" No Observed ESHWT INDEX WELL = MIW29 ZONE A INDEX WELL LEVEL FOR FEB -2015 = 8.10 Groundwater Adjustment = 1.6' or ELEV. 90.68 ALL OUTLET PIPES FROM THE DISTRIBUTION BOX MALL BE SET LEVEL FOR AT LEAST 2 FT. - �`— - 15.5" 15.5" PLAN SECTION 5'-0" on center 1 2'-6" on center 12" _CONCRETE COVER 3 - 5" OU1LEi 'r ':tr.•"•s:.�;a, 2 KNOCKOUTS OUTLET -, I 12" INLET 1.75' CROSS—SECTION 3 HOLE H-10 DISTRIBUTION BOX REV: 4/13/15 — per AHV REVIEW REV: 4/14/15 — per AHV REVIEW PLOT P LAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR ELAINE ASTU LI C 199 SOUTH SEA AVENUE ASSESSORS MAP 17, PARCEL 99 YARMOUTH, MA PREPARED BY: RHEN E. SHAY '£ ENVIRONMENTAL SERVICES N, I r ; P.O. BOX 1576 ' ' MASHPEE, MA 02649 TEL/FAX : 508-294-7498 SCALE: "wN/A SHEET 2 DRAWN BY: CES DATE: MARCH 24, 2015 PROJECT#SD2024 FILENAME: SD2024PP.DWG SHEET 2 OF 2