Loading...
HomeMy WebLinkAbout12 Eider Street - Site & Sewage PlanLOCUS --\, FOLLINS POND LOCATION MAP LOT 40 9,899 ± S.F. (0.23 ± AC.) ep N ASSESSORS MAP. 123 PARCEL, • N-40 CURRENT ZONING: R-40 (1960 SUBDIVISION) BUILDING SETBACKS: F: 30' S: 6' R: 20' FLOOD ZONE: C BENCHMARK AT CONCRETE BOUND ELEVATION - 15D 14. 28 80s2 34 KEY: r EXISTING CONTOUR: - - - - PROPOSED CONTOUR. ......••.......••••••........• EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25 TEST HOLE. UTILITY POLE: -0- FENCE LINE: -••-••-••- HYDRANT: -} RETAINING WALL. TREE: DM DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET PA. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 PHONE k FAX : (508) 398-7710 DM # SB---fD28F29B) TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 5-7-98 PERCOLATION RATE: < 2 MIN/IN TH-1 TH-2 6" /AAMPOSAND � 10YR 2/1 ELEV. 23.5 B HORIZON LOAMY SAND SO• 10YR 6/8 ZfS. C HORIZON MEDIUM SAND 2SY 7/4 f4D 120' RETAINING WALL 4 H T 22.0 T • III=III=III LE --BEV I� 4 MIL POLY 65 4.0' �- ASPHALTIC SEALING 18.0 ELEV VIII=III •. � REINFORCING STEEL- (D: :4*a#4 #4 O 18" o/c ELEV /4 O 12' o/c s PROPOSED CONCRETE RETAINING WALL (AROUND SEPTIC SYSTEM) B HORIZON LOAMY SAND 30• 10YR 6/8 19s C HORIZON MEDIUM SAND 25Y 7/4 los' 1 1 MO USCS GROUNDWATER ADJUSTMENT: YELL: AfW-247, ZONE: B, ADJUSTMENT. Of 12.0 NOTES: I. VERTICAL DATUM: ASSUMED FROM QUAD (NGVD +�-) 2. MUNICAPAL WATER IS AVAILABLE. S. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH - 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0'. 11. ALL UNSUITABLE SOIL (A & B HORIZONS ) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 12. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 13. ALL SLOPES ARE TO BE STABILIZED WITH VEGETATION UPON COMPLETION OF CONSTRUCTION. 14. DESIGN ENGINEER TO PERFORM THE FOLLOWING INSPECTIONS: 1. STAKE LOCATION OF CONCRETE RETAINING WALL. 2. INSPECT FOOTING LOCATIONS SEPTIC SYSTEM DESIGNAND REBAR PRIOR TO POURING WALL. S. INSPECT WALL HEIGHT AND LOCATION. ENGINEER TO PROVIDE CERTIFICATION OFF ABOVE TO HEALTH DEPARTMENT. FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL/DAY/BEDROOM = 330 GAL/DAY SEPTIC TANK. 330 GAL/DAY x 2 DAYS = 660 CAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 LEACH TRENCHES (33' x 2.5'x 2' DEEP) SIDE AREA: (33 + 2.5)2 x 2 = 142 SF (.74) = 105 GAL/DAY ;OTTOM AREA: 33' x 2.5' = 82.5 SF (74) = 6Y CAL/DAY TRENCH CAPACITY = 166 GAL/DAY x 2 TRENCHES = 332 GAL/DAY SEPTIC SYSTEM SECTION COVERS WITHIN 12" OF 32.5 FINISHED GRADE VNE COVER WITHIN 6" TOP OF FOUNDATION FINISHED GRADE) 22.08 PUN�DEROR ELEV. (6" OF STONE 22'3 MECHANICALLY COMPACTED) ELEV. (UNDER BASEMENT) TEE SIZES: INLET. 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN APPRVED BY: 14' ,'1Yry THOMAS McLELLAN, P.E. PROPOSED q 3 BEDROOM DWELLING 25-70 25 Y GARAGE (UNDER) DECK 4' ZWALK-OUT (ENTIRE FRONT OF HOUSE) PROPOSED DWELLING 2" PEASTONE 3/4" - 1 1/2" WASHED STONE 4" PERFORATED PVC PIPE i- ELEV: 21.8 21.83 --------------- ELEV. -BOX 2' 19.1 21.46 ELEV. 21.63 (6" OF ELEV. f SIT ELEV. STONE TWO LEACH TRENCHES 5' UNDER) 21"26 (33' x 2.5'x 2' DEEP) GAS BAFFLE ELEV. (MIN SPACING BE77IEEN TRENCHES = 79) AT OUTLET TEE ADJUSTED GROUNDWATER ELEVATION = 141 w �� DATE: Z. DEMAREST JR., SITE AND SEWAGE PLAN LOCATION. • LOT 40 EIDER STREET YARMOUTHPORT, MA. PREPARED FOR -- CHARLES MITCHELL SCALE: 1"= 20' DATE. 6-9-98 REFERENCE: PLAN BOOK 153 PAGE 39 REVISED: 6-29-98