Loading...
HomeMy WebLinkAbout32 Early Red Berry Lane Site and Sewage PlanT.O.F. AT EL. 52.5' SEPTIC PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO SO MINIMUM .75' OF COVER OVER PRECAST WITHIN C OF FIN. GRADE n RUN PIPE LEVEL 49.0' FOR FIRST 2' PROPOSED 150') 4$.28 GALLON SEPTIC 4$.0 TANK (H- 1O ) GAS BAFFLE 47.9 147.74 ( 4 % SLOPE) �_C CRUSHED STONE OR MECHANICAL o COMPACTION. (15.221 [21) DEPTH OF FLOW = 4 ( � %SLOPE) SLOPE) TEE SIZES: INLET DEPTH = 10 OUTLET DEPTH = 19 FOUNDATION— 17' SEPTIC TANK 9' D' BOX 2% SLOPE REQUIRED OVER SYSTEM 50 2" DOUBLE WASHED PEASTONE 3/4" TO 1 1/2" DOUBLE WASHED 13' PERRY LANA JOB# 97-081 LEACHING FACILITY N BENCHMARK: PK NAIL AT ELEVATION 51.1' C C MED/COS MED/COS 10YR 5/6 10YR 5/6 120" I 41.4 TEST HOLE LOGS SEPTIC DESIGN:(GARBAGE DISPOSER Is NOT ALLOWED ) 1. DATUM IS ASSUMED (DENNIS QUAD) ) DESIGN FLOW: 1– BEDROOMS ( 110 GPD) = 330 GPD 2. MUNICIPAL WATER IS AVAILABLE USE A -530 GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. SEPTIC TANK: 330 GPD ( 2 ) = 660 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H– 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. USE A 1500 GALLON SEPTIC TANK ENGINEER: A. H. OJALA, PE, PLS ENVIRONMENTAL CODE TITLE V. 2(30 + 9.83) 2 (.74) = 118 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE SIDES: = 30 X 9.83 (.74) 218 WITNESS: AMY VON HONE, R.S. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 454 SF 336 GPD t COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT USE (3) 500 GAL. LEACHING CHAMBERS WITH 4/9/97 INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED I SN,9kP �- DATE: CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. LEGEND PERC. RATE _ < 2 MIN. PER INCH OF #32 EARLY RED BERRY LANE w r 3' MAX. IN THE TOWN OF: 100 PROPOSED CONTOUR Wn, — — 100 — — EXISTING CONTOUR PREPARED FOR: V. PHILBROOK 48.45 CLASS I SOILS q N/A "4 �� MA APPI VED DATE SCALE: I r 20� DATE: �3�q 8 0 45.620„ Q ELEV. ELEV. Q I o� 51.4' 0• 50.4' a _ k 0 0 2 2„ LOCATION MAP SCALE 1" A A 5.22' 3" SL 3" SL ASSESSORS MAP 94 PARCEL C59 E LS E LS ZONING DISTRICT: R-40 (CURRENT) 8" 10YR 5/2 8" 10YR 5/2 YARD SETBACKS: FRONT = 30' EL, 40.4' TH 1 B B SIDE = 6' LS LS 24„ 10YR 5/6 49,4 24„ 10YR 5/6 48.4 REAR = 20' PLAN REF. – 187/149 (1964) FLOOD ZONE: C C C MED/COS MED/COS 10YR 5/6 10YR 5/6 120" I 41.4 120" I I 40.4 NO WATER ENCOUNTERED " NOTES: SEPTIC DESIGN:(GARBAGE DISPOSER Is NOT ALLOWED ) 1. DATUM IS ASSUMED (DENNIS QUAD) ) DESIGN FLOW: 1– BEDROOMS ( 110 GPD) = 330 GPD 2. MUNICIPAL WATER IS AVAILABLE USE A -530 GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. SEPTIC TANK: 330 GPD ( 2 ) = 660 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H– 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. USE A 1500 GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. LEACHING: ENVIRONMENTAL CODE TITLE V. 2(30 + 9.83) 2 (.74) = 118 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE SIDES: = 30 X 9.83 (.74) 218 USED FOR LOT LINE STAKING. BOTTOM: 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 454 SF 336 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT USE (3) 500 GAL. LEACHING CHAMBERS WITH INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 2.5' STONE AT SIDES AND 2.25' AT ENDS 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. LEGEND SITE AND SEWAGE PLAN 100.0 PROPOSED SPOT ELEVATION OF #32 EARLY RED BERRY LANE 100x0 EXISTING SPOT ELEVATION IN THE TOWN OF: 100 PROPOSED CONTOUR YARMOUTH (PORT) — — 100 — — EXISTING CONTOUR PREPARED FOR: V. PHILBROOK 20 0 20 40 60 HOARD OF HEALTH �� MA APPI VED DATE SCALE: I r 20� DATE: �3�q 8 off 508-362-4541 far 508 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma 02675 H Of aq� " fwe k LA" or � MA• f ARNE Qv&a H. 0 2e3+s e AR ALA, < < DATE