Loading...
HomeMy WebLinkAbout141.5 - Site and Sewage Plan (Copy 2)22 22- 21. 2-21. 4r*� ASSESSORS MAP. 141 PARCEL: 5 CURRENT ZONING: R-40 (1960 SUBDIVISION) T BUILDING SETBACKS: 1� F: 30' S: 6' � R: 20' FLOOD ZONE: -C LOCUS I 22� TEST HOLE LOGS ENGINEER: RON CADILLAC, R.S. ROUTE 6.4 DATE.-- 10-17-00 LOCATION MAP PERCO'ATION RATE: LOT 21 12,027 ± S.F. TH-2 (0.28 ± AC.) 22 22- 21. 2-21. 4r*� ASSESSORS MAP. 141 PARCEL: 5 CURRENT ZONING: R-40 (1960 SUBDIVISION) T BUILDING SETBACKS: 1� F: 30' S: 6' � R: 20' FLOOD ZONE: -C LOCUS I 22� TEST HOLE LOGS ENGINEER: RON CADILLAC, R.S. WITNESS: CHARLOTTE STIEFEL DATE.-- 10-17-00 PERCO'ATION RATE: < 2 MIN/IN TH-1 TH-2 z2S 21.0 0/�/E HORIZON ELEV. 0/ HORIZON ELEV LOA SAND Ag LOA SAND lOYR 4/2 22.1 5• lOYR 4/2 20.6 B HORIZON B HORIZON SANDY LOAk SANDY LOAM lOYR 5/8 195 40- lOYR 6/6 17.7 C HORIZON C HORIZON FINE SAND FINE SAND 25Y 6/6 2.5Y 6/6 Kv GROUND WATER ENCOUNTERED 23 / BEAT CONCRETE BOUND ELEVATION = 23.46 SEPTIC SYSTEM DESIGN KEY: EXISTING CONTOUR: - - PROPOSED CONTOUR: EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT PLEVATION: 25 TEST HOLE: -i�- UTILITY POLE: -0- FENCE ZINE: - HYDRANT: -6- RETAINING 6RETAINING WALL: TREE: DM # 02_ 55` 7 22 20 BENCHMARK AT CONCRETE BOUND ELEVATION - 2092 NOTES: 1. VERTICAL DATUM: ASSUMED FROM QUAD (NGVD +/-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH= 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0'. FLOP! ESTIMATE: :E ilEDROOMS AT 110 GAL/DAY/BEDROOM=330_CAL/DAY SEPT,'C TANK: 2,W. GAL/DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2- 500 GALLON CHAMBERS WITH 3' OF STONE ALL AROUND AND 5' BETWEEN (28' x 10.8' x 2' DEEP) SIDE AREA.- (28 + 10.8)2 x 2 = 155 (.74) = 115 CAL/DAY BOTTOM AREA. 28' x 10.8' = 302 SF (74) = 223 GAL/DAY CAPACITY= 338 GAL/DAY SEPTIC SYSTEM SECTION_ COVERS WITHIN 12" OF 23.5 (FINISHED GRADE COVER TOP OF FOUNDATION 70 BEINSPECTION WITHIN 6" OF GRADE) 77 T7 i 20.25 1500 GAL ELEV. SEPTIC TANK 20.5 (6" OF STONE UNDER OR ELEV. MECHANICALLY COMPACTED) DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET PD. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 PHONE & FAX : (508) 398-7710 TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN APPROVED BY: S Z„i 8 DECK 54' 24' PROPOSED 12' 3 BEDROOM 28, GARAGE DWELLING 24' 7t4' 42' rPRO OSE✓ D"ELLINC 3' MAX. COVER 20.0 ELEV. D -BOX 19.77- 19.94 (6 9.77,19.94(6" OF ELEV. ELEV. STONE UNDER) GAS BAFFLE 19.0 AT OUTLET TEE ELEV mom JOHN L DEMAREST JQF. No. 35853 1 }i 1'j�^111^. rr, / �- t THOMAS MCLkLLAN, P.E. 11 JOHN Z. DEMAREST JR., P.L.S. 2" PEASTONE 31,f'- 1 1/2" �-WASHED STONE ELEV.= 19.8 17.0 E3 E3 ELEV. 28' 30 2- 500 GALLON CHAMBERS WITH 3' OF STONE ALL AROUND AND 5' BETWEEN (28'x 10.8'x 2' DEEP) SITE AND SEWAGE PLAN LOCATION.- 24 ELLIS CIRCLE YARMOUTHPORT, MA PREPARED FOR: NANCY JUDGE SCALE: 1" = 20' DATE: 10 21 02 REFERENCE: PLAN BOOK 156 PACE 151