Loading...
HomeMy WebLinkAbout141.6 - Title 5 Site Plan (Copy 2)TOP FNDN. = 23.9' PROVIDE IF NECESSARY SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST /_ WITHIN 6" OF FIN, GRADE II EL. 21.68' RUN PIPE LEVEL c -- FOR FIRST 2' EXISTING EXISTING 1000 GALLON SEPTICT�\210.2'f• TANK (H—_10 )ur t '19.70' 1 r 19.87' -- o 6" CRUSHED STONE OR MECHANICAL Mas COMPACTION. (15.221 [2]) DEPTH OF FLOW - 4' MIN TEE SIZES: ( Y. SLOPE) SLOPE) INLET DEPTH = 10" OUTLET DEPTH - 14" FOUNDATION— EXIST. — SEPTIC TANK 10' D' BOX 'THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 0.58' 2% SLOPE REOUIRED OVER SYSTEM 2" DOUBLE WASHED PEASTONE 20.1' —4' AT SIDES 3' AT ENDS 3/4" TO 1 1/2" DOUBLE WASHED STONE 4 I "'. , l 03-008 LEACHING FACILITY 19.1' 5' USE ADJUSTED WATER AT EL. 14.1' TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: 4/2/03- PERC. RATE < 2 MIN/INCH CLASS I SOILS P# _ ELEV. 0" 23.0' FILL 10" BW LMS 1OYR 5/4 34" 20.2' C1 MS 50" 2.5Y 6/6 PERC C2 FS 118" OBS WATER 2.5Y 6/3 144" SEPTIC DESIGN: (GARBAGE DISPOSER IS __ NOT ALLOWED DESIGN FLOW: 3_ BEDROOMS (? Q GPD) = 330 GPD USE A- 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (_l__) = 660 GALLONS USE A 1000_ GALLON SEPTIC TANK (RE—USE EXISTING) LEACHING: FOREMND SIDES: 2(37.25 + 10.83) (.58) (.74) = 41 SEPTIC BOTTOM: 37.25 x 10.83 (.74) = 298 TOTAL: 459_ S.F. —339— GPD USE (5) STANDARD INFILTRATORS WITH 4' STONE AT SIDES AND 3' AT ENDS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR — 100 — EXISTING CONTOUR APPROVED DATE BOARD OF HEALTH eM 508-362-4541 fo. 508 382-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYE]RS 939 Main St. yarmouth, ma 02675 MA 3.2' 11_0' ASSESSORS MAP 141 PARCEL 6 ZONING: R-40 (CURRENT) FRONT: 30' SIDE: 20' REAR: 20' FLOODZONE: C WELL: SDW 252 ZONE: A ADJ: 0.9' NOTES: 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING_ 3. MINI 'U`.1 PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR ANY OTHER PURPOSE 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. LEACH PIT TO BE PUMPED AND REMOVED. ALL CONTAMINATED SOIL TO BE REMOVED AND REPLACED WITH CLEAN SAND. TITLE 5 SITE PLAN OF 30 ELLIS CIRCLE IN THE TOWN OF: YARMOUTH(PORT) PREPARED FOR: DAVID KUEHN 74-Z, c5 /7190t-- 20 0 20 40 60 Feet SCALE: i = 20 DATE: APRIL 11, 2003 - `/' / /o 3 P.L.S. DATE SEP 16 2003 FOREMND B By y o LOCUS u ELLIS CIRCLE LOCATION MAP NO SCALE ASSESSORS MAP 141 PARCEL 6 ZONING: R-40 (CURRENT) FRONT: 30' SIDE: 20' REAR: 20' FLOODZONE: C WELL: SDW 252 ZONE: A ADJ: 0.9' NOTES: 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING_ 3. MINI 'U`.1 PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR ANY OTHER PURPOSE 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. LEACH PIT TO BE PUMPED AND REMOVED. ALL CONTAMINATED SOIL TO BE REMOVED AND REPLACED WITH CLEAN SAND. TITLE 5 SITE PLAN OF 30 ELLIS CIRCLE IN THE TOWN OF: YARMOUTH(PORT) PREPARED FOR: DAVID KUEHN 74-Z, c5 /7190t-- 20 0 20 40 60 Feet SCALE: i = 20 DATE: APRIL 11, 2003 - `/' / /o 3 P.L.S. DATE