Loading...
HomeMy WebLinkAbout31.41.2 - Proposed Septic DesignSOIL TEST TOP OF FOUNDATION 20 FT, MINIMUM FROM CELLAR DATE OF SOIL TEST SEPT. 26, 2002__ 101.50 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE SOIL TEST DONE BYwEE1SER ENGINEERING ELEV. _ _^_ - CLEAN -SAND CONCRETE WITNESSED BY A. YON HONE COVERS INSPECTION PORT 4" SCHEDULE 40 PVC PIPE LOAM AND SEED WSERMATION HOLE 1 ELEV .=99.40 WSERMATION HOLE 2 ELEV.= 98.10 MIN. PITCH 1/8" PER FT.2" LAYER OFPERCOLATION RATE _ 2T MIN./INCH AT __64 INCHES PERCOLATION RAT5_2__ MIN./INCH IN NQ�ORIZON ' I ILA DEPTH HORIZI TEXTURE COLOR MOTT. I OTHER 0-10 1/8" TO 1/2" SANDY LOAM 3,00 4" CAST IRON PIPE NO ROOTS 10-30 B 98.10 MAX. WASHED STONE VENT C ROOTS 0-120. C MEDIUM SAND 2.5Y7/4 95.85 MIN. NOT REQUtP.ED PIOTCHQ /4, PER FTM z REVISED SHEET 1 OF 1 FLOW LINE 95.10 O ELEV. 6 ASO 10" MIN. ELEV,LEVOEL 22 0 0 ELEV. GAS ELEV. _ 98 8_T_ 6" SUMP ELEV. _ _9 . 010• - - = ESV' = 9377 BAFFLE DISTRIBUTION LIQUID OUTLET. �� ' BOX ELEV. U 4 HIGH CAPACITY INFILTRATORS WITH TEE (TO BE PLACED ON FIRM BASE) -QO- STONE IN AN 4 FEET 14 INCHES TO BE WATER TESTED _� _. _� __.._. ____-__-. i 67 I ILA DEPTH HORIZI TEXTURE COLOR MOTT. I OTHER 0-10 O/A SANDY LOAM 10YR3/3 NO ROOTS 10-30 B LOAMY SAND 10YR5/8 C ROOTS 0-120. C MEDIUM SAND 2.5Y7/4 JOB N0. 5526-00 DEPTH HORIZ I TEXTURE COLOR MOTT. OTHER 0-14 O/A SANDY LOAM 10YR3/3 NO ROOTS 14-34 B LOAMY SAND10YR5/8 ROOTS 34-144 C MEDIUM SAND 2.5Y7/4 SCALE 1 „ = 2O=' 5 FEET 19 INCHES G IF MORE THAN ONE OUTLET ti A O F IV IMLN ,n rUNW IIUry _ 6 FEET 24 INCHES 1500 GALLON SOIL ABSORPTION NO WATER ENCOUNTERED AT _120' ELEV. _ __,g9 40 NO WATER ENCOUNTERED AT 144" ELEV. 7 FEET 24 INCHES (TO BE PLACED ON FIRM BASE) - WELL Nom. 8 FEET 34 INCHES SEPTIC TANK 3/4" TO 1 1/2" CLEAN CZONE DOUBLE WASHED STONE SYSTEM (SAS) INDEX ADJUST FREE OF FINES & SILT LEGEND: DESIGN CALCULATIONS USGS PROBABLE WATER TAB_E ELEV. = EXISTING SPOT ELEVATION 00.0 NUMBER OF BEDROOMS 4__ SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED WATER TABLE ( / / ) ELEV. - EXISTING CONTOUR ----00---- GARBAGE DISPOSAL UNIT NOT TO SCALE BOTTOM OF TEST HO -E ELEV. _ _$Q 1Q_ FINAL SPOT ELEVATION TOTAL ESTIMATED FLOW ��O FINAL CONTOUR ( 110 GAL/811./DAY X 4 BR.) --440_ GAL./DAY SOIL TEST LOCATION REQUIRED SEPTIC TANK CAPACITY -9Q- GAL. /} I� UTILITY POLE -0- ACTUAL SIZE OF SEPTIC TANK 1500 GAL. !/ TOWN WATER —W --W— SOIL CLASSIFICATION '%p T CATCH BASIN �c j DESIGN PERCOLATION RATE $_ ¢� MIN./IN. 179 GAS LINE EFFLUENT LOADING RATE 9J-4- GAL./DAY/$.F. S8 (� CLEAN OUT C� LEACHING AREA 8233 SO. FT. • `-'a ; S�C/ CESSPOOL C.P. Q (11x4E+(59x2xlo/t2) D LEACHING CAPACITY (AREA X RATE) -4111 GAL./DAY X 0.74 ti og RESERVEBLEACH NG CAPACITY _4014a GAL./DAY NOTES: ry :1I, S=CT I - 1 ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D E P 1 TITLE 5 AND THE TOWN OF _NeHMQUgLRULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS, H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NC DETERMNA^.CN HAS BEEN MADE AS TO COVPL!ANCE WITY DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY: 6. UTILITIES SHOWN ARE APPROXIMATE ONLY. EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE __G 9. LOT IS SHOWN ON ASSESSORS MAP _ 31 _ AS PARCEL 41-2 TA: DUMAS No 619 bC G APPROVED: BOARD OF HEALTH IST J DATE AGENT GINEERING ROUTE 28 lata _ � EXETER ` BR HILL SILVERLEAF PROPOSED SEPTIC DESIGN. FOR a43: S PROJECT LOCATION 1 O LOT DllJ,l 71. YARMOUTH EXETER ROAD, LiJJ i Si;'EE75ER ENGLNERMG 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE SEP 27, 2002 SCALE 1 „ = 2O=' JOB N0. 5526-00 REVISED LOCATION MAP REVISED SHEET 1 OF 1 GINEERING