Loading...
HomeMy WebLinkAbout38.69 - Title 5 Site Plan29 TOP FOUND. EL. 23.3' 4. PRECAST H-10 SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 22.0' MINIMUM .75' OF COVER OVER PRECAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 91P.' SI OPE REQUIRED OVER SYSTEM 121.7 BLOCKS OR RISERS (TYP.) 4"1ASCH40 PVC MORTAR ALL PRECAST RISERS COMPONENTS H-10 PIPES LEVEL 1ST 2 ' �ENDS (TMP') INV'S EL, 3 SIDES 19.5' V*20.0 1500 GAL H-10 14" 19.62' TEE SEPTIC TANK TEE0-0 �0�� 0 0001-] ��0�-� - �0�� 'o°o°o°o° 19.37 0.-- '0.'0' o ;0000.000 ��D�OODO��C] �000��000�0 > ° ° ° ° �oo�0000�o�� 00000�000�o 00000000 0 0 0 0>°°°° DOO�MDMM�MC] ������0���� 00 0 0 0 0 0 0 000��0����0 �����000�o� ;00000000 00 0 0 0 > o 0 0 0 GAS BAFFLE ::: 0�0uo0„0„0- ,0000°°°° ° ° ° ° )0000°o°° �����a���� c� a�ooaao�aao °o°o 18.90' 18.73' '°O°°°°°° °o°°°°° 16.63 r: 4' LIQ. LEVEL (ACME OR EQUAL) .' °°°°°°°° ° ° °^° 000000 0000000000000000000000000000000a00000o? 0,0,,0„0_00_no.o� _n 0 0 0 0 0 0.�_�_ _n_0.0 0 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H -1L0 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.0' X 12.83' COMPACTION. (15.221 [21) o WATER -TEST D'BOX FOR LEVELNESS cO (-L-% SLOPE) ( 1 +% SLOPE) (-!-% SLOPE) ' 40' D' BOX 12' LEACHING 10.6' BOTTOM TH-1 FOUNDATION 19 SEPTIC TANK FACILITY NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- 99- EGEND99- EXISTING CONTOUR X2.23 EXIST. X 99.1 EXIST. SPOT ELEV. HOUSE 99 PROPOSED CONTOUR SUITABLE SOILS TO BE CONFIRMED BY INSTALLER PRIOR TO INSTALLATION OF ANY PORTION OF SEPTIC SYSTEM, AND PRIOR TO ANY F991 PROPOSED SPOT EL. O / -1.63 EXCAVATION/CONSTRUCTION FOR DWELLING TH1 7 2 } TEST HOLE EXISTING LEACHING �. Y FACILITIES, INCLUDING i \ 91.18 2,% SLOPE OF GROUND STONE, TO BE PUMPED x AND REMOVED IN ENTIRETY; i x REMOVE ALL C -CD 7Opg CONTAMINATED SOILS. NOTE: GARAGE FOOTINGS S \ F i R FIRE HYDRANT TO BE -PLACED ON----- Is 51 NATURAL' SOIL (NOT FILL) NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING \\ gRFq % OWNERS ^ j� FNCF ATE TIMING WIX TH /^\\\ ; / % / x 21.75 N �V TEST HOLE LOGS /� x DECK � , � ENGINEER: DANIEL E. GONSALVES, SE �� x 21.57/ PRO�; / GARP x 60 WITNESS: AMY VON HONE, RS ,,`'� /� �� �j (SLAB) DATE: 10/16 /13 ' / ' TH 1 < i / 26. TH 2 PROP. 3 BR PERC. RATE _ < 2 MIN/INCH SHED/ 1.58 DWELLING x 67 TOP FNDN. CLASS I SOILS xjOO EL. 23.3' N x ECFV. ELEV. HIGH PT. / x //Mh G 1 2 �G p 21.6' 21.6 x21. 19 � X x 21. i / , A A \ x 21.85 �1 / LS LS x .61 x 21.2� 10YR 4/2 10YR 4/2 10" W$ 21.30 LS LS x 2 69 y�Q�O21.98 7s6 x 21.22 25" 19.5 194' 10YR 6/8 26„ 1OYR 6/8 .'9� F _1.69 x1.04 / I C C \ \ / \` PERC >t 21.30 BENCHMARK: USE SURVEY SPIKE IN x 21.41 MS MS GROUND AT ELEV. 21.7' 1OYR 7/4 1OYR 7/4 132" I 110.6' 120" 1 - NO GROUNDWATER ENCOUNTERED ,3-258 11.6' Scale:1 "= 20' 0 10 20 30 40 50 FEET x 20.83 x 20.97 X 9.14 LOT 7 ' 16,683 SFS X Q.j3 X .10 )4/1-1 DATE NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. orse O 'Pond Rd. d B� ck I51a� o ndy C,_ � 0 D nd 0 �o L CU c P�. LOCUS MAP NOT TO SCALE ASSESSORS MAP 38 PARCEL 69 LOCUS IS WITHIN FEMA FLOOD ZONE "C" ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' BLDG COVERAGE 25% PROP COVERAGE 11.8% SITE IS NOT LOCATED WITHIN APD SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW EXISTING SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD d 1 .27 BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 471 S. F. 349 GPD 17.70 USE (2) 500 GAL. H-10 LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF Y --Louth Plealth Dep wrtment las Date FILA r 12 FEATHERBED LANE WEST YARMOUTH PREPARED FOR CHRIS CHAPIN NOVEMBER 11, 2013 REV. 1/6/14 (DWELLING & SEPTIC REVISIONS) off 508-362-4541 I fax 508-362-9880 downcope.com down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675