HomeMy WebLinkAbout136.39 - Site Plan and Sewage Disposal System (2)E 3 /3 �DESIGN SYSTEM T.O.F. ACCESS MANHOLES TO WITHN I/8'�o 1/2' (' � �=I • : ' ; �. ELEV. 51.0 wored Design Flow: '3 bedrooms C�//D gal/day 33U gal. q � stone .,., y-7. � 6" OF FIM'SHED GRADE g (.J Septic Tank:330 gal. x 200/ - a6 gal ELEV. `r74 t ev X of Use 1500 Gal. Tank �y %• 3 o s/a't o I I� Leaching F a c i l i t y: USE' (',, S0° (,4lz1 / C//A,r1 F,hk' S v./ 4' STaNE rushed „ ?AP ROVED Bottom: _ 2 ,�5 x 3 3, 5 >C o . 7 �kti l S - % <� 1,` 3 M _ . stone RD MITT GAS J / 14 BAFFLE _ o e -- eem S i des : //z.8+ 33•S�yZx 0 74g4115- - '� /f OCH ®emeee Z ,� % <�� dol e o eee � emeee e e°ee°e PLEV.4g.0 . ....... = a _ TOTAL �( 54 G I .Use 6' crushed stone veaeevaemee eeevoeem0�d � � D FOLUNS 3 under Septic Tank and NOTE: Garbage disposal is not Permitted with this design. 7' ND , D -Box �- �{ u+�e ZS.S --�- 4 -� EN�rn1EE27o vErzlF�' St�rLS ��. ELEV. 4b.$ ELEV. 14k 4.4� 6 5' 5'Ftrw of 1 `461iv� r'L'/Lr,-v jT77AIF'or< -hvx,_�,�n�sJ L OCA TI ON IAP 1500 GAL. D -BOX ELEv.39.g Assessors Mo SEPTIC TANK LEACHING FACILITY PJ36 Btm. T.H.4r2 Parce! 39 _SYSTEM PROF II F Area -,6,324 S.F. of o 5ooe CONSTRUCTION DETAIL 5 TEST. -HOLE I TEST HOLE #2 SEPTlC TANK STONE fS' - OUTLEr LEACHING UNIT — o EL. 50.5 r o EL . 49.9 !4' oo v —r _ _ LOA l eeor 000a ® ° A MY SAND LOAMY SAND 0000000ppobrao®vo 34' ¢ �- IOYR 4/3 A IOYR 3/1 6- �� 0 O 'o co B LOAMY SAND LOAMY SAND 4S - GAS BAFFLE DETAIL loz �'� `C5a r'jw IOYR 5/6 B IOYR 4/6 N. T. s. 28- 30- 500 GALLON CHAMBER 4' C 'MEDIUM COARSE FINE/MEDIUM PD 120' 120' 12 5Y 6/4 n v!T,'-:..D N R� ti� „A , � Air` `zLFNu-IMAtzIc. tS T°� vC(E Y�9tznlou rH �� NOTES DATE: JANUARY 18. 2001 i � HYD WOND - ELEV,St.¢ �6 , 4s.9 I ) SEPTIC TANK SEAM I S TO BE SEALED AND PERFORMED BY : RICHARD JUDD, R . S C. BAS IN �. WITNESS: A. VON HONE , H.A. r F-9 WRAPPED. DESIGN RATE: <2 min./in. I� 1 ai. <D so.8 i - -? 2.) ALL AREAS DISTURBED BY CONSTRUCTION ARE TO BE GRADED. LOAM COVERED. Q U y9B/ r j : ` AND SEEL'ED. FND '- — o {' 3. UNSUITABLE SOILS ARE TO BE REMOVED FOR PERCOLATION A t (as si®a r 50.6 r + r a 6.4 5'AROUND-LEP,CHING AREA AND REPLACED f ERCOLl1T 1 UN '1"EST '44-1 it c•. IRE j— 50'6 I r r /O WITH APPROVED FILL MATERIAL ;j : 4) DESIGN ENGINEER TO CERTIFY SOILS REMOVAL 24 GALLONS OF WATER IN 5 MINUTES AND 33 51 032.67, ' BEFORE SYSTEM INSTALLATION. SECONDS AT THE DEPTH OF 58 INCHES 51.1 r0' o 5.) DESIGN ENGINEER TO CERTIFY SYSTEM INSTALLATION [� 44Ce F. U PRIOR TO BACKFILLING. s�ar3 6.) DISTRIBUTION BOX 15 TO BE WATER TESTED AT Z00 TH*I— — v 45.3 THE TIME OF THE BOARD OF HEALTH INSPECTION, O THIS PLAN IS FOR .THE INSTALLATION OF SEWAGE J 49 o wA7 R 5; s .' s I ^ DISPOSAL SYSTEMS ONLY AND IS NOT TO BE USED PERCOLATION Z -y- E S T #2 ` w FOR ESTABLISHING PROPERTY LINES. PERCOLATION TEST WAVED. (1J soeoT +z W S� AeCE�S M�NkoLES aE 7a >3e" cFA1ENtE7� /WPL/1cErF�ct Z 4s.9 2 ti E.vGlNEE/Z U/ru- ctRi1FY SXST£M 1A15TAtl-AT/oN J48j� 6 N 45.3 PKSET N CN a Rxlk 49.3 48.8 6@T i`t EC3 ® E {vu O 47.8 LL 941 MAIN STREET. SO. HARWICH, MA 02661 U.P.4: oe 46.6 432-2878 CB/FND I Sl TE PLANfs. SE"JAGE DISPOSAL SYS 106.45• TEM /N YARI'90UTH 47.8 48.4 I.P./FND FOR 47.6 DEBBIE f'' JOHN BYRD-71 ...i 2 FOUL I NS POND ROAD YARMOUTH, PIA.. PROJECT: 01-0051 SCALE: I ` 30 DA TE: 31-77-101