HomeMy WebLinkAbout51.28.1 - Title 5 Site PlanPRECAST H-10 (TY RISERS `..1 .) 2'a *17.25' 15.75' SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE FOR FRONT YARD SYSTEM ONLY 1 D.O.°a°°r°o.r°e,°,o�°,°,o°o°o°o" WATER TEST D'BOX FOR LEVELI n _ _ _ .o.0 0 6' CRUSHED. STONE OR MECHANICAL COMPACTION. (. 15221 [21) (T5% SLOPE) l 3 % SLOPE) FOUNDATION- 20' - SEPTIC TANK 18' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99- EXISTING CONTOUR 0 P' ZPIPESVEL EXIST. SPOT ELEV. LI 10" 1500 GAL HI TEE SEPTIC TAN5.5' PROPOSED SPOT EL. TH1 USE A 1500 GAL. H-10 SEPTIC TANK TEST HOLE 000°o°o°o°o oo°�p0000^oo SLOPE OF GROUND PER UTILITY POLE 4' LIQ. LEVEL (ACME OR EQUAL) ' 14.89' 14.72' D.O.°a°°r°o.r°e,°,o�°,°,o°o°o°o" WATER TEST D'BOX FOR LEVELI n _ _ _ .o.0 0 6' CRUSHED. STONE OR MECHANICAL COMPACTION. (. 15221 [21) (T5% SLOPE) l 3 % SLOPE) FOUNDATION- 20' - SEPTIC TANK 18' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. - �- PROPOSED CONTOUR ® PROPOSED SPOT EL. TH1 USE A 1500 GAL. H-10 SEPTIC TANK TEST HOLE 2� SLOPE OF GROUND PER UTILITY POLE FIRE HYDRANT NOME: NOf ALL SYWOMS WY APPEAR N 2!U MR16 TEST HOLE LOGS ENGINEER: DANIEL GONSALVES, SE WITNESS: AMY VON HONE, RS DATE: JANUARY 10, 2013 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS Q ELEV. 0" t 18.1' A LS 16" 1OYR 3/2 B LS 40" 1OYR 5/8 14.8' C PERC M/CS 1OYR 7/6 132" 1 7_1' NO GROUNDWATER ENCOUNTERED 12-326 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PORTION OF PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET/ SPECIFICATIONS OF 310 CMR 15.255(3) (AT WESTERLY END OF SAS, INVERT INTO B LAYER) 2R SLOPE REQUIRED OVER SYSTEM ALL SYSTEM COMPONENTS SHALL BE MARKED WRH MAGNETIC TAPE OR COMPARABU. MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3' OF FINISH GRADE / F-871 Il m 17.85 1 11 1.83 Scale: l "= 30' 0 15 30 45 60 75 FEET 7' NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-j,Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE, 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR. CONCEALED WITHOUT. INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED. FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE .PROPOSED LEACHING FACILITY. 12. EXISTING CESSPOOL SHALL BE PUMPED AND REMOVED REF. LCA 21438 B AND DECISION BY BUILDING COMMISSIONER, DATED 6/16/09, AS SHOWN ON TOWN OF YARMOUTH LOT INQUIRY FORM FOR LOT 5 REFERENCE SEPTIC SYSTEM INSPECTION DATED DEC. 11, 2012 (SYSTEM PASSED FOR 4 BEDROOMS UNDM OLDER`IITM' DATE "b�NAL t.. S1flkalb \` at , DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 51 PARCEL 28.1 SYSTEM DESIGN: (FOR FRONT YARD SYSTEM ONLY) GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 44 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 220 GPD/0.74 GPD/SF = 297.3 SF LEACHING REQ'D 297.3 SF/29.56 SF/UNIT = 10.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF 1' H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION SHOWN 11 UNITS x 29.5 SF = 324.5 SF > 297.3 SF 32F_(1L = GPD OK) i armOUth Health Department e LOCUS MAP NOT TO SCALE ASSESSORS MAP 51 PARCEL 28.1 SYSTEM DESIGN: (FOR FRONT YARD SYSTEM ONLY) GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 44 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 220 GPD/0.74 GPD/SF = 297.3 SF LEACHING REQ'D 297.3 SF/29.56 SF/UNIT = 10.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (11) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION SHOWN 11 UNITS x 29.5 SF = 324.5 SF > 297.3 SF 32F_(1L = GPD OK) i armOUth Health Department APPROVED DATE BOARD OF HEALTH MA TITLE 5 SITE PLAN OF 18 FONTNEAU ROAD LIJ SOUTH YARMOUTH Z PREPARED FOR 4 ARTHUR HASTINGS V N REV.)ANUARY 1/24/131tLOT1LINE) I off 508-362-4541 fax �508-362-9880 downcape.com C down cope engineefkg, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675