HomeMy WebLinkAbout123.117 - Site Plan{ R ACCESS COVERS MUST BE WITHIN 9' MINIMUM, 6" OF FINISH GRADE 3' MAXIMUM COVER 102.0 FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE OR FILTER FABRIC 2:�11�Pt 3/4' - ! 1/2" DDA. 99.0 98.5 97.5 2' s' DOUBLE WASHED STONE 98.75 ` GAS 97,67 BAFFLE 3 OUTLET 2-500 GAL LEACHING CHAMBERS D -BOX W/4' STONE AROUND. 12.8'xx 33'1 x 2'd 1500 GAL SEPTIC TANK 6" CRUSHED STONE OR COMPACTED BASE PROF 1 L E: NOT TO SCALE INVERT r TP #t INVERT AT 4 y INVERT /N SEPTIC TANK: 98.75 INVERT OUT SEPTIC TANK: 98.5 INVERT IN DIST. BOX: 64 INVERT OUT DIST. BOX: 97.5 INVERT IN LEACH CHAMBER: 97.4 BOTTOM OF LEACH CHAMBER: 95.4 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: f V � TEST HOLE +2: 90.1 O ORGANIC O LOCUS MAP { R ACCESS COVERS MUST BE WITHIN 9' MINIMUM, 6" OF FINISH GRADE 3' MAXIMUM COVER 102.0 FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE OR FILTER FABRIC 2:�11�Pt 3/4' - ! 1/2" DDA. 99.0 98.5 97.5 2' s' DOUBLE WASHED STONE 98.75 ` GAS 97,67 BAFFLE 3 OUTLET 2-500 GAL LEACHING CHAMBERS D -BOX W/4' STONE AROUND. 12.8'xx 33'1 x 2'd 1500 GAL SEPTIC TANK 6" CRUSHED STONE OR COMPACTED BASE PROF 1 L E: NOT TO SCALE INVERT ELEVATIONS TP #t INVERT AT BUILDING: 99.0 INVERT /N SEPTIC TANK: 98.75 INVERT OUT SEPTIC TANK: 98.5 INVERT IN DIST. BOX: 97.67 INVERT OUT DIST. BOX: 97.5 INVERT IN LEACH CHAMBER: 97.4 BOTTOM OF LEACH CHAMBER: 95.4 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE +2: 90.1 DES l GN CR 1 TER 14: DESIGN FLOW: 4 BEDROOMS AT 110 G.P.D. PER BEDROOM FOUALS 440 G.P.D. GARB/'"- TINDER SEPTIC Tar... REQUIRED: 440 G.P.D. X 200V - 880 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. S('IL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 M/N/INCH SOIL TEXTURAL CLASS - 1 EFFLUENT LOADING RATE - 0.74 GPD7SF 440 GPD / 0.74 GPD/SF - 595 S.F. REOUJRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W74' STONE AROUND. A-606 S.F. 606 S.F. x 0.74 - 448 G.P.D. SOIL TEST PIT DA TA INDICATES �_ INDICATES PERCOLATION - OBSERVED TEST GROUNDWATER 3•:� •.H o1 4; r M1ta. 9,y," C. FRh�YF, i' FILE COPS' GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN, J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 4' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EOUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'• 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 9. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. omouth Health Depa APPROVED ,5 / T E P L A /V O/=- L A /\/ 0 / FOR TU/VE ROAD . MAP / -:710. PARCEL YAR"0UTHPOR T, "A , ^PREPARAED F/OR H _ A A , ✓ 0 LEGEND TP #t TP R2 02639 [?CB CONCRETE BOUND HORIZON TEXTURE COLOR WATER LINE SCAL E : / - 20 TEXTURE COLOR O HYDRANT 0" -G- 101.6 0'..WIR1ZON I NC 1 NC /00.1 OVER HEAD WIRES O ORGANIC O LIGHT POST I•, i ORGANIC -E- UNDERGROUND ELECTRIC LINE' �y 4- ._...._.. ___.. ....... ._ 101.3 2' .......__ ............._.._............ -CTV- UNDERGROUND CABLEVISION L INE 99.9 ( 508 ) 432-5333 A LOAMY IOYP, A LOAMY IOYR SAND 312 SAND 372 l0' __..._.._....._...___ _..._... 100.8 12' ...._.._._..__........._........... 99.1 B LOAMY IOYR B LOAMY IOYR SAND 578 SAND 578 24 _._......._ 99.6 32 ___........... .. .. ............. 97.4 Cl FINE -MED IOYR Cl FINE -MED IOYR SAND 6/4 SAND 6/4 44' 48" .....__.. ........................._._ 96.1 60' ..................... ..._..__.... 96.6 n -.MEDIUM IOYR SAND 773 C2 MEDIUM IOYR SAND 7/3 - �p 120" NO WATER 9/ 6 Off, NO WATER 90.1 DATE: JANUARY 3. 2006 TEST BY: STEPHEN h.44S WITNESSED BY: AMY VONHONE PERC RATE: ( 4 MIN/INCH 3•:� •.H o1 4; r M1ta. 9,y," C. FRh�YF, i' FILE COPS' GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN, J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 4' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EOUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'• 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 9. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. omouth Health Depa APPROVED ,5 / T E P L A /V O/=- L A /\/ 0 / FOR TU/VE ROAD . MAP / -:710. PARCEL YAR"0UTHPOR T, "A , ^PREPARAED F/OR H _ A A , ✓ 0 LEGEND P. O BOX 76.5 DEN/V / SPOR T. MA 02639 [?CB CONCRETE BOUND -W- WATER LINE SCAL E : / - 20 DECEMBER / S . 2008 O HYDRANT -G- G45 LINE E -ACL_ E SUFRVEY I NC 1 NC - OHW- OVER HEAD WIRES O LIGHT POST 923 Rou t a 6A -E- UNDERGROUND ELECTRIC LINE' �y Yo rmo u t h p o r t . MA . .02675 -T- UNDERGROUND TEL EPHONf L I NF //�i� i��j 1 gogz�--k ( 5 0 8) 362-81,32 -CTV- UNDERGROUND CABLEVISION L INE ( 508 ) 432-5333 + 40.4 SPOT ELEVATION _ _40- - EXISTING CONTOUR P-?Tr CONTOUR .. 0 /0`..."-,20. .._.__.-40 'B NO: 06-141 FIELD:CFW/EEK J CALC: SAH/CFW I CHECK: CFW DRN: SAN f FILE COPY 11 G