Loading...
HomeMy WebLinkAbout22.211 - Title 5 Site PlanSYSTEM PROFILE TOP FNDN. AT EL. 16.4' ACCESS COVER TO WITHIN 6" OF FIN. GRADE NOT TO SCS ACCESS COVER (WATERTIGHT) TO WITHIN 6" OF FIN. GRADE 14.0' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 4 } 14.4' (EXIST.) PAfl ROPOSED 1500 GALLON SEPTIC 12.0' TANK (H— 10 ) 0-0% SLOPE) DEPTH OF FLOW = 4' TEE SIZES: INLET DEPTH - 10" OUTLET DEPTH — 14" FOUNDATION 23' RUN PIPE LEVEL fFOR FIRST 2' 11.75' TEE BAFFLE 11.16' �� GAS 10.99' CRUSHED STONE ORMECHANICAL 4PACTION. (15.221 [2]) (-1-0% SLOPE) (—!—X SLOPE) 100.0 PROPOSED SPOT ELEVATION +100.0 EXISTING SPOT ELEVATION — - loo-- EXISTING CONTOUR X FENCELINE a CESSPOOL TEST HOLE LOGS ENGINEER: DAVID FLAHERTY, RS WITNESS: P. RENAUD DATE: 9/14/06 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 0" Q 13.4' — A LS 9" 1OYR 5/2 B LS 36" 7.5YR 5/8 10.4' C PERC FMS 2.5Y 6/4 115" OBS WATER 3.8' 120" 3.4' 06-225 2" DOUBLE WASHED PEASTONE PROVIDE INSPECTION PORT WITHIN 3" OF FINISH GRADE 11.30' INFILTRATORQUICK 4 STD. • �• ONES 07-4 SEPTIC TANK 6' D' BOX 4' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM GROUNDWATER ADJ. DATA: WELL:- MIW 29 ZONE: B ADJ: 1.5' LEACHING FACILITY 5' USE ADJ. WATER AT EL. 5.30' Scale:1"= 20' 0 10 20 30 40 50 FEET NOTES 1. DATUM IS ASSUMED v 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H– 10 0 5. PIPE JOINTS TO BE MADE WATERTIGHT. LOCO 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH ec MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO�, ewis BE USED FOR ANY OTHER PURPOSE. Pon 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. Bay 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND LOCUS MAP PERMISSION OBTAINED FROM BOARD OF HEALTH. ASSESSORS MAP 46 PARCEL 72 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCUS IS WITHIN FEMA FLOOD ZONE THE LOCATION OF ALL UNDERGROUND & OVERHEAD B AS SHOWN UTILITIES PRIOR TO COMMENCEMENT OF WORK. ON COMMUNITY PANEL #250015 0005D 11. PUMP AND REMOVE/FILL WITH SAND EXISTING CESSPOOLS DATED 7/2/92 CURRENT ZONING: R25 SEPTIC DESIGN: I GARBAGE DISPOSER IS NOT ALLOWED I DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW i SEPTIC TANK: 330 GPD (2) = 660 ' USE A 1500 GAL. SEPTIC TANK j I =i LEACHING: SIDES: 2 (38 + 10.8) .67 (.74) = 48 GPD -- -- - - ,__, --- _[30TT0M —:__ _ ..3$_ x -108 (J!4) 303 GPD TOTAL: 474 S.F. 351 GPD USE (8) QUICK 4 STANDARD INFILTRATORS WITH 3' STONE AT ENDS AND 4' AT SIDES 0 � iS a6 DATE , MA APPROVED DATE BOARD OF HEALTH OF 56 FRANKLIN ST. EXT. . Vi/EST YARMOUTH I PREPARED FOR DANIEL AND CAROL GOLDBERG WORK MUST CONFORM BYLAWS AND REGUL r F1 OF SSS OF MASS ����H ARNE H ARNEFi OJALA OJALA CIVIL N 30792 No. 48 P O 1-11 1ST' _ E U/ TOWN SEPTEMBER 15, 2006 Z . OJALA, P.E., P.L.S. off 508-362-4541 fox 508-362-9880 I down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouthport, ma 02675 SEP 2 5 2006 06-225—SP.DWG (SBO) C UILLAN'f L° I