HomeMy WebLinkAbout355 Great Island Road Building Sections3)i %X'6" LVL
RIDGE
2x8 16" O.G.
)2x8 HDR
6 16" D.G. 7
A.7
2)1 3/4xq%4" LV 1�7 2x12 RIDGE BEYOND CONTINUOUS RIDGE VENT
2
A ASPHALT ROOF SHINGLES • F / \
2x10 16" O.G. 5/8" CDX SHEATHING
s 7 n Al ALLEY 15# BUILDING PAPER
3)I /4x11 /0 V
LVL 2xB CEILING JA q
---JOISTS 16 O.G.
2x5 DECK JOISTS
16" O.G. TYP.
FOR CANT. DECK
A.q
EXTEND NOTCHED
NEWEL POST TO
HEADER S THRU BOLT A G1
SECOND F R —
I I ill i✓ -�
�� II II II
;'
II
-II
II
II
II
IIV155
Illi
URCON
45YII
\p 111
II
II
I
II
II
IIP
SII
II
I
ii
II
I
I
u
II
II
II
n1
III
� =
� In
v III
a
II
II
I
I
II
II
II
II
II
II
III
III
F
m
i
i III
III
II
II
I
II
II
II
O
IIIIII3
_�
h
1-
0
ZUJ III
II
IIII
�
I
m
F*
li
3J41
p
Lj
II
I�NIIII
II
II
III
III
11 R-30 FSGLS. INSUL
)2x12 HDR. A
II 2x10 DECK JOISTS
TAPERED TO 8" RAFTER VENT
A.7
2x8 CEILING
RID JOISTS 16" O.G.
/ 2x10 16" O.G.
2x12 RIDGE
FOR ROOF DECK VENT BAFFLE — R-Iq FBGLS. INSUL
I I ,�//
II \ IX FASCIA W/ 2)fx10 2)2x10 2X6®16" O.C.
II '� ALUMINUM GUTTER 1 "
II 14CADEP p = w , HEADER 1/2 CDX. SHEATHING
r, TYP. U.N.O.
II 1 IX SOFFIT mTYP. U.N.O. � _ � I/2" GWB
II
-OF STRIP VENT r f z ;_-' G VAPOR BARRIER
II IX FRIEZE J ~ A TYVEK HOUSEWRAP
1X4 MAHOGANY DECKING _+_� u _ w I SIDING (SEE ELEVS.
11 / " TJI 16" IO.G. Y -- -- tj --------- '-3 = - r----- )
2x10 DECK JOISTS = n 0
2)1 %xq%4" LVL 7 n n FLUSH A.7 I6" O.C. TYP. i r j o In
LEDGER 11 /3 TJI 16 O.0 s 7 „ 3)2x12 HDR. mR-1q FBGLS. INSUL / 3)1 X11 /3 LVL 1X4 MAHOGANY DECKING * p +) �y a o x10 16 O.C.
2X6616" O.G. 2)2x10 3 2x12 HDR. * 3
2xS CEILING
HEADER ip 3/4 TSG PLYWOO SUB -FL R JOISTS 16 O.C.
I/2" CDX. SHEATHING 2x10 DECK JOISTS " , ,�
" TYP. U.N.O. 6x8 CANTILEVERD ; TAPERED TO 8" GLUED AND N ILED, TYP BELOW
I/2 GWS i w (BEAM w/ 11 3/ 7%4" LVL A.7 FOR ROOF DECK EXTEND NOTCHED
J p BEDROOM #i ° HEADER S THRU BOLT 2x10 LEDGER _ - -_--- - - SECOND FLOOR
VAPOR BARRIER r = EACH SIDE OR DECK NEWEL POST TO �— . — . — . EC . — . — , —
TYVEK HOUSEWRAP i+ - B
SIDING SEE ELEVS. w �� 7 „ ,i
( ) v \ 2x10 16 O.G. FLUSH 2)2x10 11 /0 TJI 16 O.G. FLUSH %
RIM JOIST GUT TO SHAPE 3)2xi2 HDR. I i _� HEADER 3)I s/4x11 7/" L
\ 3/4" TSG PLYWOOD SUB -FLOOR 3
/ GLUED AND NAILED, TY z % MIN. DEPTH 8" TYP. U.N.O.
FIRST FLOOR_ _ _ \ / Q --------- - -- - -- - -- - - - - 2)2x12 HDR.
f1 11 7/" TJI 16" O.C. it 7/" TJI 16" O C 1 j a -- -- _ ; _ --- I I
)1 `40 7�" LVL A.q -- z „
+ _; i v z 3/4 TSG PLYWOOD SUB -FLOOR
HEADER I I -- -- � ,° z I I
/ Z MUD ROOM w GLUED AND NAILED, TYP
/ 3)1 7/ LVL FLUSH FOR DECK JOISTS' -
G 12 FLUSH DROPPED FOR ROOF- - -- - * z CONCRETE STEPS
A.q f--,
w/BLUESTONE
DROPPED STEEL SEAM W12X40 3) CUSTOM BRACKETS- ❑ N VENEER
ENCASED IN
1 �FIRE RATED )1 3/4x11 7/8'LVLm \
6X6 6/6 WWF TOP 1/3 OF SLAB LO
ao o DRYWALL CONTINUOUS HDR l _ G FIRST FLOOR
z- --- _ - J -
4" CONC. SLA * , F�11 "TJI 16" O.G. I "TJI 16" — — — — — — .
2X6 P.T SILL — u GARAC,E L SEE D AIL T� — . —T.O F, 10.0'
W/ SILL SEALER STONE VENEER < / i �� L '' • ' / J
/ r 12' DUST' CSP /l®
GARAGE SLAB 7.0' NG \ o a is+ Q — — — . — — . —
DUST CAP 7.7' NGVD
f. rim--1-L-------1-L - ---.-- -_-- A 3
a CRAWL i to a H
6" COMPACTED FILL _ Z 8"x16" SMART VENT / v * z * z SPACE 2CRAll r o 41 z°
o SPACE ACCESS a °
coo _ o ' 10' THICK w/ LEDGE ACCESS
) F• o (CERTIFIED FOR 200 S0. FT.) /
a I 10" THICK x 4'-8" ` CONCRETE WALL ON °
TO BE NO MORE THAN 12 CONTINUOUS 20"x10" DROF%PEj� LVL z o
z I I CONCRETE WALL ON ABOVE FINISH GRADE IN ) a e
n " CONCRETE FOOTING `r
CONTRCTOR SHALL ONTINUOUS 20 x10 ANY LOCATION. 14 COVERED w/ LINE 14MAINTAIN 4B" MINIMUM CONCRETE FOOTING q �z TJI 12" O.C. 16 VERIFY HEIGHT w/ GRADE
A.q
FOOTING COVERAGE A,$ w/ DOUBLE SLEEPERS A.$ ( 16
OR ROO� DECK
SLOPED /0 PER FT.
SECTION A.8
1X4 MAHOGANY DECKING-} IS SECTION
13 A.7 \ A.5
A.6 EXTEND NOTCHED
// // �fEMPERED GLASS PANELS C
/ /
NEWEL POST TO
RIM JOIST S THRU BOLT L /
2x10 DECK JOISTS )1 3/4xq%4" LVL HDR.
TAPERED TO 8"
FOR ROOF DECK H 2x10 DECK JOISTS
3: A 7 TAPERED TO 8"
�y = FOR ROOF DECK
ciDZ MEDIA ROOM LOFT
J
* u 3/4" TSG PLYWOOD SUB -FLOOR - -
1 GLUED AND NAILED, TYP
A.7 FLUSH STEEL BEAM W12X5 IX4 MAHOGANY DECKING
LOFT FLOOR
— . — ' — — ' — ' — — ' — ' — — — 2x10 LEDGER2x10 LEDGER
li FBGLS. INSUL til 117/" TJI 16" O.C. F__ __ )I3/4xgy4" LVL
2X6®16" O.C.
1/2" CDX. SHEATHING 2x6 CEILNG
„ JOISTS I�' O.G. / - ` 2x6 CEILING
1/2 GWB ------ JOISTS 16" O.C.
VAPOR BARRIER ' ~ _-_-- 2)1 A
T 3/ 11 7/s" LVL
TYVEK HOUSEWRAP \ j j FLUSH
SIDING (SEE ELEVS)
A.8 z ------ 2x12 RIDG
G POST DN
FLUSH * u ------ TO HDR
3)2x12 HDR. A.q \ M.BATi-{--------
.-12x10 Ib" O.C.
\3/4" TSG PLYWOOD UB -FLOOR - LOFT
X4 MAHOGANY DECKING--------
' JOISTS 16" O.G.
SECOND FLOOR _ GLUED AND NAILED, TYP - -- - 2x8 CEILING
2x10 LEDGER 11 /" TJI 12" O.C.--------I
- _— - -
2x10 DECK JOISTS / 2)1 3/4x117/8' LV __1 117/g" TJI ib" O.G.
16" O.G. TYP. - -- -i / 3)2x12
C FLUSH-------� FOYER HEADER
F 3 2x12 6"x6" P.T. POST
1(0 H AD WRAPPED TO 10"
I 7 i ------ t-- SQUARE YPICAL
1 1 A.8 _ �------ 1(0 w
�i 1 4" CONCRETE SLAB KITCHEN � � � w �------ W
W _ I- -------- z A.
w/BLUESTONE TOP �) J --- - $ O
A.q a F 1 4" G CRETE SLAB
II 3/4" Ti PLYWOOD SUB -FLOOR * PANTRY tu
!I w/BLUESTONE TOP
I .LUESTONE PATIO \ GLUED AND NAI ED, TYP / J
FIRST FLOOR — — _ —� — — — — — — / `%/ CONCRETE
RUESTONEPS
— VENEER
T.O.F 100 NGVD—,—,—,�•
11 7 " TJI 12" O.G. 11 "TJI I " O.C.
" * STONE VENEER 6" COMPACTED FILL 2)1 3/4x11 7/8' LVL /' J
p i J / 3)13/4x117/s" LVL FLUSH " RUST CA J
FLUSH J / = 3 T.O.F. 8.6 NGVD
is oz DU--- - NGVD_ _ 3 — — — — _ _UST CAP
/ J, 3 — — - o—
° in a 3 _ "n ° 8" THICK
* ° CONTRCTOR SHALL of a CONCRETE WALL ON i z ° C THICK
+1 z * ° „ ` ° a * CONCRETE WALL ON
MAINTAIN 48 MINIMUM v CONTINUOUS 16 x8 „ a ? ° CONTINUOUS 20"x10"
a - 10 THICK w/ LEDGE +� °
FOOTING COVERAGE m CONCRETE FOOTING / z o CONCRETE FOOTING
VERIFY HEIGHT w/ GRA E CONCRETE WALL ON 3 I/2" CONC. FILLED VERIFY HEIGHT w/ GRADE
I CONTINUOUS 20"x10° STL. LALLY COLUMN
f CONCRETE FOOTING ON 36'x36"x12" DP. 8" THICK
VERIFY HEIGHT w/ GRADE CONC. FOOTING, TYP. CONCRETE WALL ON
SECTION CONTINUOUS 16"x8" C
CONCRETE FOOTING
17 15 VERIFY HEIGHT w/ GRADE A.q
A.8 A.8
11 7/8" TJI I6" O.G.
FLEX DUCTS FLEX DUCTS
PVG SUPPLY PVC RETURN
AIR DUCTIII
AIR DUCT IF
:�T
2x NAILEF
VENTURECLAD JACKET SYSTEM
(1577CW )
2x NAILERS WRAPPED AROUND DUCTS
1/2" P.T. PLYWOOD
DROPPED LINE -X
3)13/4x11 %" LVL 1/4" COATING
COVERED w/ LINE -X
I
DUST CAP
WATERPROOF DESIGN
ZERO PERMEABILITY
STRUCTURALLY SOUND
DESIGNED IN ACCORDANCE WITH
780 CMR 120.G501.5
780 CMR 120.G501.7
780 CMR 120.G501.8
WATERPROOF DUCT SYSTEM
SCALE 1-1/2" - I'-0"
0
W
U � Y
a w
Wof O o U
H
U
(n �
O O
� o
5; o_
w o
O
� rn
� 04
\
w
W
w
V)QQ z W H0�_
W JZ <80M005
XO-�OZ
W Q W 0
.LLI�O w m s Z O w Lo� WEZ O
W F- ~
F- of <V) z
�w�Fmo��w
w om z
dpf � w r o Z m O w L) ZU—'
moral -<Of
0 ow0 X: xzw
U zwOZOw�wao
6 p) No
N 0rn
w L0N
0
0
_ d
0 wUl 0
d ¢ }
P=
w '
�o
N
W �
F- Z M
Q
Z �-
m
�
an
0
>
�Fpo 2_ Z�0 ¢J
wO,NjZ���•"'ZZUZ QIYKZ 6Ott�
OZKZh ZON�U O,W-�(�UO\�~
�ww�-oz,^�oaoiwF�w
OW Z Y dU
mho`"-0(;a0opFjil`Iii<a
o
J=ual-w h¢nOUomw
oKZ
OOz<W �OK=WV2aU
ON
�W/zNzoa3�o/
0< zs
WKU W
y1QJJ¢Q�il��S�ZOOW maZ Wm
QF-QSUN�JOaO~QZw0QW�K
N F�m0
VQOOVQWa4�0(NA_
U
J
� J
w
v W Q=
W �ACz�
Ld
< �4
Z w w I-
Q (LLLj
,n 3
ro l j m
3
vi w
. c O w ?
z ~ ZD
Q Q N U
>a
O L 3
Z O J Z Q
Q Q m o o
CIL v w
V) N U O
�Z4�W
J>-zm
m0=
z
00
0
H \
�O s a N
O
WLd
r
U W
2