HomeMy WebLinkAbout355 Great Island Road Site Plan 4SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 MIN. GAL. SEPTIC TANK BOTTOM AREA ONLY: 13.5' (+/-) X 50.3'= 602 SFX .74) = 446 GPD USE A 602 SF LEACHING FIELD AS SHOWN MA APPROVED DATE BOARD OF HEALTH NOTES 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 - 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. NO"BASEMENT" ALLOWED. FLOODZONE RESISTANT DESIGN REQUIRED (BY OTHERS). FINAL GRADING TO BE IN ACCORDANCE WITH FEMA REGULATIONS AS SHOWN. 14. ALL RUN-OFF TO BE CONTAINED ON-SITE DESIGN REQUIRED (BY OTHERS). FINAL GRADING TO BE IN ACCORDANCE WITH FEMA REGULATIONS. 15. DRYWELLS (OR DRIP TRENCHES) SHALL BE INSTALLED TO CONTAIN ROOF RUN-OFF. 16. CONTRACTOR TO COORDINATE ALL UTILITY DISCONNECTS AND NEW SERVICES WITH APPROPRIATE VENDORS. 17. CONTRACTOR TO NOTE ORDER OF CONDITIONS COVERING ANY WORK ON SITE TO BE ISSUED BY THE TOWN OF YARMOUTH CONSERVATION COMMISSION. COPY OF ORDER TO BE ONSITE AND ALL CONDITIONS AND SPECIAL CONDITIONS SHALL BE ADHERED TO. REQUIRED INSPECTIONS AND CERTIFICATIONS 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS COMPLETE. 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING OF WALL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY DEPOSITED 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND PUMP MECHANISMS AFTER INSTALLATION ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT THE RETAINING WALL, SEPTIC SYSTEM AND PUMP MECHANISMS HAVE BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED PLAN. *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM FIRSTR^'�ELFV. 11.0' CONCRETE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE RAWLSPACE SLAB .6' TOP FOUNDATION 100f WITHIN 20' OF SAS REMAINDER OF CRAWLSPACE 9'S SLAB AT EL. 7.4' MINIMUM 75of cov ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. MARK CORNERS OF LEACH FIELD WITH 24" #5 REBAR WITH SAFETY CAP DRIVEN JUST BELOW GRADE EACH CORNER OF LEACH FIELD. 4" DIA PERF. INSP, PORT TO SAND AT BOTTOM OF LEACHING FIELD. 4" THREADED CAP TO WITHIN 3" OF FINISH GRADE 40 MIL LINER FROM ELEV. 8.8' TO ELEV. 4.8' MIN. RETAINING WALL SCHEMATIC SHOWN, EXACT FASCADE OVER PRECAST F9-.5. TOP PIPE 8.6' AND CONSTRUCTION BY OTHERS. TOP OF WALL HT. AS NOTED FLOOD VENTS WITHIN 12" GRADE 4"scH40 PRECAST H-10 FINISHED GRADE- 4" LOAM & SEED 2% MIN: SLOPE OVER SYSTEM a. RISERS (TYP.) PROP. TEE . 2'0 4"OSCH40 PVC 16 (GROUND AT EL. 7.4) REQ. 10 2500 GAL PIPES LEVEL 1ST 2' CLEAN FILL VENTS ON 2 SIDES REQ. ` 4" PERFORATED PVC. CAP ENDS o e ^ s 7 2' SEPTIC TANK/PC 5=0.005 0 FLOOD VENT/FOUNDATION DESIGN COMBINATION D 'a , BY OTHERS. " �< 1J o a°'°eo°o^°o�°oo$o o� 3/4"-1-1/2" DOUBLE WASHED STONE LEACHING FIELD o SHOREY OR EQUAL ° °oo°o oo°'o°000Ooo 0, . 6"DEPTH �% MIN BELOW INV. e 7.5'* 8.52' 8.35 8.25 LEVEL D n PROPOSED ROCK WALL VENEER (SEE DETAIL U ) } / BOTTOM o 8.00' :-;.•, > ; 55 > DEPTH OF FLOW = 4' 00000000000000000000 O C BLOCK UP FOR p4' COVER TYP. 5' MIN.UNSUITABLE 000000000000000000000000 D -BOX ACME DB -5 OR EQ. :pe,,• , d; SEPTIC SYSTEM PROFILE 7.50' SOIL REMOVAL. no no INLET DEPTH = 10" OUTLET DEPTH = 14" 6" CRUSHED STONE OR MECHANICAL WHERE SPECIFIED ° °1 DEPTH PER SOIL LOGS e COMPACTION. (15.221 [2]) 5.0' ooa 0000000 00 00 TIDALLY INFLUENCED GROUNDWATER _ 2.5' (-L- %SLOPE) ( 2 %SLOPE) (_1_X SLOPE) LEACHING: USE A 602 SF LEACHING FIELD 602 SF X .74 = 445 GPD O.K. FOUNDATION 15' - SEPTIC TANK 2' D' BOX 12' LEACHING FACILITY LOT 80 0.54 ACRES± (12,745± UPLAND) ,111, dll, NOTE: WETLAND RESOURCE AREAS FLAGGED BY LEC ENVIRONMENTAL CONSULTANTS, INC. P � LEC FLAG � QQ� pPQCir �"ii 7� 011, FLAG yAP 1!, v 7 SMptX / .c o ' dI1, dlr, 00�N�^ 100 ' 5P PROP. SITTING 00 / dll. IIL #2�/ WALL AT EDGE I AH -I ,, MW / OF PATIO / (LEC) (DCE) 111, alr, \��♦ J,� alr, / JSP e°e�' SM#3 •� %% _aQ o Q•t��Q / �O / PROP, VENT WITH CHARCOAL FILTER AND SUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) PROP. 4 BR DWELLING FIRST FL. ELEV. 11.0' (CRAWLSPACE SLAB ELEV. MIN. 8.25') •. �A, A a / / ,�o� SFI O i Y�r 5 UNSUITABLE SOIL REMOVAL / LIMIT AROUND LEACHING FIELD �J \\ SITE PLAN Scale: I"= 20' NOTE: NO INCREASE IN TITLE 5 DESIGN FLOW, NOT "NEW CONSTRUCTION" UNDER TITLE 5. 0 10 20 30 40 50 FEET VARIANCES REQUESTED UNDER MAXIMUM FEASIBLE COMPLIANCE 15.405: (1a) LEACHING FIELD TO BE LOCATED 7.5' FROM LOT LINE (10' REQUIRED) VARIANCE OF 2.5' REQUESTED (1f) LEACHING FIELD TO BE LOCATED 25' FROM DRAIN WHICH MAY INTERCEPT HIGH GROUNDWATER- 50' REQ. 25' VARIANCE REQUESTED, WALL/LINER PROVIDED VARIANCE TO LOCAL BOARD OF HEALTH REGULATIONS REG. 3.7: LEACHING AREA TO BE 70.4' FROM COASTAL BANK, 100' REQUIRED, 29.6' VARIANCE REQUESTED Aj PROP. RET. WALL TW = 9.0' (DESIGN BY OTHERS) BICE # 09-130 WATERLINE TO BE SLEEVED THIS AREA PER WATER DEPT. ` PROP. RE- LOCATED >6 WATERUNE PROP. BENCHMARK: C. BASIN AT I ELEVATION 4.95' NGVD29 ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION NOTE: 50ak GAL RESERVE ALARM AND CONTROL PANEL PROVIDED IN PC TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 7.2' SEPARATE CIRCUIT FROM PUMP ZABEL FILTER 2" PRESSURE UNE FLOAT SWITCH ALARM ON (A1DO) 14" TEE SLOPE TO DRAIN BACK SETTINGS: OUTLET TEE W/EXTENSION PUMP ON 1000 CAL MI. WEEP HOLE 5' WORKING RANGE 6' THIS SIDE CHECK VALVE OF BAFFLE 5• e8, MYERS SRM 4 PUMP OFF 1Y SUBMERSIBLE4/10 HP PUMP SYSTEM (OR EQUAL) 4 DOSES PER DAY, AT 110 GAL. PER 000000 c.� (ON BLOCK) DOSE (5' WORKING RANGE) �� oo s a r" 2500 GAL. SEPTIC TANK/PUMP CHAMBER COMBINATION (NOT TO SCALE) TEST HOLE LOGS ENGINEER: DANIEL A. OJALA PE, PLS SE1805 WITNESS: AMY VON HONE RS, CHO DATE: JULY 1, 2009 PERC. RATE =. < 2 MIN/INCH CLASS I SOILS ELEV. 4 2 0„ 7_0 0.. Q 7.0' FILL FILL 3" LOAM 3" 24" 24" LOAM THEN SAND THEN SAND A LS A LS 27" 10YR 3/2 27" 10YR 3/2 B LS B LS 42" 10YR '5/6 3.5' 42" 10YR 5/6 3.5' PERC BATT. AT C 1 C1 52", 24 GAL IN 9:30 < 2 MIN/INCH M/C S M/C S GROUNDWATER DEPTH 56.4" 2.5 Y 7/3 O EL. 2.3' 2.5 Y 7/3 el. 2.3' BUT TIDALLY INFLUENCED - SEE BELOW - 120" _3.0 120" -3.0 NOTE: MONITORING WELL OVER LUNAR CYCLE EL. 2.5 TIDALLY INFLUENCED- USE 2.5 NGVD29 AS ADJUSTED HIGH GROUNDWATER ELEVATION (AUTOMATED MONITORING WELL SET, AND READINGS TAKEN OVER NEW MOON CYCLE DURING HIGHEST TIDES OF JUNE) 4" DIA PERF. INSP. PORT TO SAND AT BOTTOM OF LEACHING FIELD. 4" THREADED CAP, SCH40 PVC THREADED CAP TO WITHIN 3" OF FINISH \GRADE 27 MIN. FINISH GRADE \ MIN. 3' MAX. 10" MIN. i LOAM AND SEED MIRAFI 140N FABRIC DATE OR 2" PEASTONE 5' MIN.;j 3/4" TO 1 1/2" DOUBLE ADJ. _ WASHED STONE (NO FINES) GROUNDWATER 5' MIN.UNSUITABLE SOIL REMOVAL CROSS SECTION VIEW WHERE SPECIFIED DEPTH PER SOIL LOGS LEACHING FIELD TYPICAL DETAIL NOT TO SCALE SCALE 1"=2000'± ASSESSORS MAP 14 PARCEL 3 DATUM: NGVD LOCUS IS WITHIN FEMA FLOOD ZONE B & Al2 ELEV. 10 AS SHOWN ON COMMUNITY PANEL #250015 0005 D DATED JULY 2, 1992 (NOTE: ELEVATIONS, BASED ON NGVD, INDICATE ENTIRE SITE IS WITHIN THE 100 YEAR FLOOD ELEVATION) WETLAND RESOURCE AREAS FLAGGED BY LEC ENVIRONMENTAL CONSULTANTS, INC. ZONING SUMMARY ZONING DISTRICT: R-25 MIN. LOT SIZE 25,000 S.F. MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. LOT COVERAGE: 25% UPLAND AREA (TO C. BANK) = 12745 SF PROP. LOT COVERAGE: 23.87 SITE IS LOCATED WITHIN AP DISTRICT REFERENCES �ql CTF 139728 -W- LCP 14426H, LOT 80 -X- LEGEND . RODOALPH &�'+ M. MICOZZI JUNE 12, 2009 EXISTING CONTOUR X 99'1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 TEST HOLE 21 SLOPE OF GROUND C -Q) UTILITY POLE �ql FIRE HYDRANT -W- WATER LINE -X- FENCE LINE LOT LINE POST LIGHT NOT ALL SYMBOLS MAY APPEAR IN DRAWING j vrnuth V^=1'h Department H OFMgSSITE PLAN o� DANIEL 9cc SHOWING PROPOSED DWELLING A, ' OJALA AT " No. 40980 �q0 ESS o� 355 GREAT ISLAND ROAD RV - WEST YARMOUTH ILA, P.E., P. S. PREPARED FOR B I off 508-362-4541 80 fax ncape. om @ downcape.com dawn cape engineering, j#C. . RODOALPH &�'+ M. MICOZZI JUNE 12, 2009 civil engineersREV• land surVe Ors y 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 JULY 1, 2009 (TH LOGS ETC.) REV. JULY 14, 2009 (FLOODZONES, ETC.) REV AUG. 10, 2009 (CRAWLSP. ELEV.) REV AUG. 18, 2009 (HEALTH DEPT. NOTES) REV AUG. 24, 2009 (FRONT STEPS) REV. SEPT. 15, 2009 (LOT COV).) REV. SEREV. APRILP T. 15? 2010 o( MOVE SEPTIC) Scale: 11"= 20' 0 10 20 30 40 S0 FEET II