Loading...
HomeMy WebLinkAbout341 Great Island Road - Site Plan of LandIZONE "Al!" --BASE FLOOD EL. 1 1 .0, A5 SHOWN ON FIRM 2500 1 C0588J, DATED I MAY 3, 2013 DEEP OBSERVATION HOLE #3 (OG -20-2013) EL. G.4 NOTE: EXTEND ALL MANHOLE COVERS TO WITHIN G" OF FINISH GRADE r 4" SCH 40 PVC PIPE rPIPE TO BE LAID LEVEL FOR / 2' OUT OF DISTRIBUTION BOX T.O.F. @ EL. 12.5 io° IS^ 10.10 L �C 9.23 CKAWLSPACE SLAB 9'75 IN OUTLET TEE 9.40 @ EL. 6.0 -� 9.50 -_L 6" BASE OF - 1 500 GALLON PRECAST 3/4" STONE SEPTIC TANK DEPTH SOIL SOIL 501L COLOR SOIL OTHER DATE: FROM HORIZON TEXTURE (MUNSELL) MOTTLING FROM HORIZON SURFACE (MUNSELL) MOTTLING TELEPHONE: (508) 328-4692 SURFACE HORIZON TEXTUREOTHER 0" _ G., A LOAMY SAND I OYR4/3 O ORGANIC G" - 121t B LOAMY SAND I OYR5/G LOAMY SAND I OYR4/3 120 - 3G" C I FINE SAND 2.5YG/4 I OYR5/G 30- 72" C2 MEDIUM SAND 2.5YG/3 GO" - 84" II ) WATER ENCOUNTERED @ GO" (EL. 1.4) arse PC •• 2" LAYER OF 3/8" PEA5TONE OVER 3/4" - 1 1/2" DOUBLE WASHED STONE (5) 500 GALLON PRECAST DKYWELL5 SEPTIC SYSTEM PROFILE INSPECTION SCHEDULE I . INSPECT 501L REMOVAL 2. STAKE RETAINING WALL LOCATION 3. INSPECT FOOTINGS * REBAP 4. INSPECT FINAL INSTALLATION OF SEPTIC SYSTEM 4 FINAL GRADING O I.5 0 O / 2.7 / 41�/ EXISTING DWELLING -- V 5 // TO BE DEMOLISHED J( 5.1 (3) HIGH CAPACITY INFILTRATOR (51DEWINDER) CHAMBERS FOR ROOFRUNOFF / O /4.9 \ c, G / \.95, �•� LANDSCAPE WALL I .S C (BY OTHERS) T \ oa \ ``� �• I 4. \oSF\ 5.7�• i I L, P/61p NOTE: THERE WILL BE NO LANDSCAPING/ a �,� --- NX AT THE REAR OF THE HOU5E. AREA 1'S+ / `" Ell ,' OOH Lh �O TO REMAIN IN IT'S NATURAL STATE. ANY D15TUPBED AREAS TO BE REPLANTED WITH INDIGENOUS MATERIALS. + `y���o�® \ -d 5' TOP @ EL. 9.7 BOTTOM @ EL. 7.00 MAXIMUM GROUNDWATER @ EL. 2.0 WALL TO BE MADE WATERPROOF USING ASPHALT MASTIC -- TO BE 5 MIL THICK WHEN DRY -TBM = EL. 10.0 (NGVD) NAIL SET IN UTILITY POLE G/5 0 0,9 X, PROPOSED 100% EXPANSION ` ♦ , TH #2 WATER EL. 7.4 SERVICE ; AREA y , PROPOSED WORK LIMIT LINE- STAKED INE STAKED HAYBALE5 * SILT FENCE : Tn #3 - (3) HIGH CAPACITY INFILTRATOR �� ' / TH #; , , (SIDEWINDER) CHAMBERS FOR \ ' ; EL o.4 ROOF RUNOFF 8" POURED CONCRETE RETAINING z `°o WALL (WATER -PROOFED) TOP @ EL 10.0 , 8.3 / , , c8d 7.0 DEEP OBSERVATION HOLE LOGS DATE: 08-24-2007 TEST BY: M. O'LOUGHLIN, CSE WITNESS: A. VON HONE, HEALTH AGENT FERC RATE: < 2 MIN. / INCH DEEP OBSERVATION HOLE # I EL. G.4 DEPTH FOR 341 GREAT ISLAND RD., WEST YARMOUTH, MA PREPARED FOR ROGER McGOVERN SCALE: DATE: SOIL SOIL SOIL COLOR SOIL JOB NUMBER: 07-03G FROM HORIZON TEXTUREOTHER (MUNSELL) MOTTLING TELEPHONE: (508) 328-4692 SURFACE HORIZON TEXTUREOTHER (MUNSELL) MOTTLING 0.-311 O ORGANIC 3'- 7" - A LOAMY SAND I OYR4/3 7" - 19" Bw LOAMY SAND I OYR5/G 19" - GO" C I FINE SAND 2.5YG/4 GO" - 84" C2 MEDIUM SAND 2.5YG/3 WATER ENCOUNTERED @ G8" (EL. 0.7) DEEP OBSERVATION HOLE #2 EL. 7.4 DEPTH FOR 341 GREAT ISLAND RD., WEST YARMOUTH, MA PREPARED FOR ROGER McGOVERN SCALE: DATE: SOIL SOIL SOIL COLOR SOIL JOB NUMBER: 07-03G FROM SHEET NUMBER: SP -1 WELLER * ASSOCIATES I G45 FALMOUTH RD., SUITE F9 P.O. BOX 4 17 CENTERVILLE, MA 02@32 TELEPHONE: (508) 328-4692 EMAIL: tri5weller@cjmall.com HORIZON TEXTUREOTHER (MUNSELL) MOTTLING SURFACE O" - 3" O ORGANIC 3" - 7" A LOAMY SAND I OYR4/2 7" - 21 " Bw LOAMY SAND I OYR5/G 21"-48" CI FINE SAND 2.5YG/4 48" - 84" C2 I MEDIUM SAND I 2.5YG/3 WATER ENCOUNTERED @ 80" (EL. 0.4) MAXIMUM GROUNDWATER ELEVATION USED: EL. 2.0 NGVD EL. 10.2 8" POURED CONCRETE WALL •- USE 3000# CONCRETE _ EL. G.2 #4 BAR 12" ON CENTER EACH WAY (3) #4BAR CONTINUOUS THRU FOOTING EL. 2.2 2' O" I RETAINING WALL DETAIL' DESIGN DATA DAILY FLOW: (4) BEDROOMS x I 10 GPD = 440 GPD SEPTIC TANK: 440 GPD x 200% = 880 GPD USE: 1 500 GALLON PRECAST SEPTIC TANK DISTRIBUTION BOX: USE: DB -9 SOIL ABSORPTION SYSTEM: USE: (5) 500 GAL. DRYWELL5 LINED w/2' OF DOUBLE WASHED STONE ON ALL AROUND CAPACITY: 51DEWALL AREA: III x 2 x 0.74 = I G4.3 GPD BOTTOM AREA: 9.0 x 4G.5 x 0.74 = 309.7 GPD 474.0 GPD GENERAL NOTES I . REMOVE ANY IMPERVIOUS MATERIAL FORA 5' RADIUS AROUND SAS AND REPLACE WITH CLEAN MEDIUM SAND. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN ACCORDANCE WITH 3 10 CMR 15.00: TITLE V. 3. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ANY UTILITY, ABOVE OR UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 4. THI5 SEPTIC SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL. 5. THIS PLAN IS NOT TO BE USED FOR PROPERTY LINE DETERMINATION. G. CONTRACTOR SHALL PROVIDE 48 HOUR NOTICE TO DESIGN ENGINEER FOR ANY REQUIRED INSPECTIONS. SITE PLAN OF LAND FOR 341 GREAT ISLAND RD., WEST YARMOUTH, MA PREPARED FOR ROGER McGOVERN SCALE: DATE: DRAWN BY: 1 11 = 20' 09-10-2007 TMW JOB NUMBER: 07-03G REVISION: OG -24-2013 SHEET NUMBER: SP -1 WELLER * ASSOCIATES I G45 FALMOUTH RD., SUITE F9 P.O. BOX 4 17 CENTERVILLE, MA 02@32 TELEPHONE: (508) 328-4692 EMAIL: tri5weller@cjmall.com REGISTERED LAND SURVEYORS * ENVIRONMENTAL CONSULTANTS