Loading...
HomeMy WebLinkAbout240 Great Western Road Site PlanCOVER TO BE WITHIN SOIL TEST TOP OF FOUNDATION s" of FINISHED GRADE —\ DATE OF SOIL TEST 01/25/2012 9gss Rl� FIZ ELEV 104.00CONCRETE AMY VON HONE,HA O COVERS INSPECTION PORT 3/4" TO 1-1/2" CLEAN WASHED STONE WITNESSED BY Q S 9" MIN. COVER TYP. 4" SCHEDULE 40 PVC PIPE SOIL EVALUATOR DAN CROTEAU-S13772 MIN. PITCH 1/8" PER 2" PEASTONE Q O� 131"r,PERCOLATION RATE <2 MIN./INCH. "- 102.50' F— — E`"= OBSERVATION HOLE 1 tyFST� \c�OP ELEV.= 102_62_ Rti RQ �'QO 1 CLEAN BACKFILL ELEV.= DEPTH HORI TEXT COLOR MOTTLING FLOW LINE =' Y2 LOCUS 100.50' TANK TANK 99.64 Q 102.45 0-2" 0 ORGANIC NONE ELEV. _ __ ELEV. = 99_89ELEV. _ _ 2 MI OO OO O O 00 OO 10" 14" L EL 99.26' — fMIN. i 4'-0" ELEV 99.43' ELEV. _ _ DO o0 000 00 00 101.95 2-8" A LOAMY SAND 10YR3/3 4" CAST IRON PIPE LIQUID ELe/• = 99.24'- (OR 9.24' (OR EQUAL MINIMUM LEVEL GAS BAFFLE T e%e.'_ _; �%•�' `" ' - _;;;.'` PITCH 1/4 PER FT. ISTRIBUTION 3 ;r`K's ' '�:' ' ' '''° "'` ' '' ~ ` ` _ 97ss' 100.29 8-28" 8 LOAMY C. 10YR5/6 e,. ,:,: ; _; LOCATION MAP ,rr .,� r :a.._ . , r` -._... ELEV. SAND �_ BOX 98.87' 28-45° Cl COARSE SAND 10YR6/6 TO BE WATER TESTED H10 STRENGTH 3 4' x 8' 3' ST 91.62' 45-132 C2 COARSE SAND 2.5Y6/2 ,2' x 3D ASSESSORS MAP: 101 ' BOTTOM OF EST HOLE ELEV. = 92.93' NO WATER AT 132 EL.= 91_62' PARCEL: 180 1500 GALLON MECHSTONE NICAEN NATIVE LY COMPAC EDU BASEND R PERC. AT 44" SEPTIC TANKS 4'x8' CONCRETE FLOWDIFFUSOI S H10 STRENGTH H2O STRENGTH PLAN REFERENCE - OBSERVATION HOLE 2 ELEV.= 10293' NOTES- PL.BK.' 395 PG. 50 DESIGN CALCULATIONS PROPOSED 4 BEDROOM DWELLING DAY x BEDROOMS x 110 GPD/BEDROOM ___ 440 GAL.— / TOTAL ESTIMATED FLOW _ 440_ GAL./DAY GARBAGE DISPOSAL UNIT _ NO REQUIRED SEPTIC TANK CAPACITY 330 X 2 _ 880_ GAL. ACTUAL SIZE OF SEPTIC TANK _ 1500 GAL. LEACHING AREA REQUIREMENTS SIDEWALL AREA 0 74 GAL./S.F. BOTTOM AREA 0.74 GAL./S.F. LEACHING CAPACITY SIDEWALL- (12+12+40+40)X 1.25 = 130S.F BOTTOM- 12X40= 480S.F. S.A.S. COMPONENTS 4 - 4'x8' CONCRETE FLOW DIFFUSORS ON 3" OF 3/4 - 1-1/2" CRUSHED STONE WITH 4 FEET OF STONE SIDES AND END TOTAL- USE 4 - 32 SF DIFFUSORS - -1 c SQ.FT. WITH 4' OF STONE SIDES & ENDS AND 3" UNDER RESERVE LEACHING CAPACITY _610 SQ.FT. REQUIRED 440 GPD / 0.74G/SF=595S.F.<610 O.K. ((12x40) + (40x2)2 + (10x2)2)0.74 = 503.2 GPD SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE LOT 15 30,000 SO. FT. f 0.69 ACRES t 776.00 PERIMETER CB/DH(FND) STK(SE rn so , ^\1 99 \ 99.16 STK(SET) Q CB/DH(FND) / 2 \ _ 1 / \ PK�ET) lb 10 103' \ 102.433 \A\ \1 102.93' 44.59' PROD I .OS 20.00' o\ ° B 4 x 28! 00C \ O �\ 2.4�' 1 \ tlo 103.17' o� o ° 1 \\ \\ N O 65 0 3W 10262' 1 Jo \, 18, 6.5 Oo r POOF Ep 4 _ 4 �N\\ 1\ 1 1 a �OUNOq NOM pweC `- j� \JOJ\ 61 96. 4 \ 1 l �04.Op/NC o 102.,E +\ 1 � � 36.00. _ --� 999,.58' 337 \-\99.92- — � \ 3 ELEV. DEPTH HORIZ TEXT COLOR MOTTLING 102.68 0-3" 0 ORGANIC NONE 102.10 3-10" A LOAMY SAND 10YR3/3 100.18 10-33' B LOAMY C. 10YR5/6 SAND 98.26' 33-56" Cl COARSE SAND 10YR6/6 92.93'56-120' C2 COARSE SAND 2.5Y6/2 NO WATER AT -L20 - EL.= 92.93' PERC. AT 53" APPROVED: BOARD OF HEALTH DATE AGENT o �-- 14\a� N'-----� PROP) DRIVEWAY \� 00 k� i / \O 0 r 1 \ ) 101.50' �-- DRIVEWAY TO BE CONTAINED 141-e \w_ r \ \ \\ WITHIN THE PROPERTY LINE �'— \PK(SET) �w A-570, CATCH BASIN W ' BM EL.=100.00Ep E\0, i / G w APpRO PAV �MeN E CO \W WATeR UN F i 1 \W\tOC4TjON 1) SEPTIC SYSTEM TO BE INSTALLED ACCORDING TO 310 CMR 15.000 TITLE 5 AND THE TOWN OF _-'ARMQUTU _ RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2) EXISTING AND FINAL GRADES SHALL REMAIN ESSENTIALLY THE SAME. (UNLESS ELSEWHERE NOTED) 3) ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H --LO LOADING. 4) ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5) NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING. 6) THE INSTALLER IS TO VERIFY THE LOCATION OF UTILITIES AND SEWER LINE ELEVATIONS PRIOR TO INSTALLATION. 7) SOIL ABOVE THE C LAYER (SHOWN ON SOIL LOGS) SHALL BE REMOVED AND REPLACED WITH CLEAN SAND ACCORDING TO MASS. LOCAL SPECIFICATIONS WITHIN 5' AND BELOW THE S.A.S. 8) EXCAVATION FOR AREA WHERE FILL IS REQUIRED SHALL EXTEND 5 FEET LATERALLY BEYOND S.A.S. 9) VERTICAL DATUM ASSUMED DATUM ------ 10) BENCHMARK __ CATCH BASIN/EL=100.00' 1 1XLL PRECAST UNITS ARE TO BE PLACED ON 6" MIN. CRUSHED STONE MECHANICALLY COMPACTED. 12) GROUND COVER OVER SYSTEM COMPONENTS SHALL NOT EXCEED 3 FEET 13) ALL EXISTING UNUSED COMPONENTS SHALL BE PUMPED, REMOVED AND/OR FILLED WITH CLEAN SAND ACCORDING TO LOCAL REGULATIONS. 14) CONTRACTOR TO VERIFY ALL PLUMBING IN THE BUILDING FLOWS TO PROPOSED SEPTIC TANK. 15)THIS PROPERTY DOES/DOES NOT FALL WITHIN THE WATER RESOURCE AREA. 16) THIS PROPERTY FALLS IN FLOOD ZONE _--JULY-2.1992 AS SHOWN ON FIRM COMMUNITY PANEL N0. 2500015 0002 D _ DATED JULY 2 1992 17) SITE PLAN SHOWING PROPOSED HOUSE & SEWAGE DISPOSAL SYSTEM IN YARMOUTH, MASSACHUSETTS AS PREPARED FOR TIM BAKER 240 GREAT WESTERN ROAD