HomeMy WebLinkAbout8 Grouse Lane - Sewage Disposal System Repair with Addition, SOIL TEST PIT DATA: TEST PIT -#1L GRD. EL. 81.2 EST. HIGH GW. 69.7 DATE: LOAMY S ND 10YR 4,3 1 LOAMYB SAND 10YR 5 6 EL = 78.7 Ll MEDIUM SAND 1OYR 7/3 EL = 69.7 1 10/10/07 TEST BY: THE BSC GROUP, INC. )" WITNESSED BY. AMY VON HONE PERC. RATE: 2 MIN./INCH SOIL EVALUATOR 0" AAARK nIRR OCTOBER 10, 2007 HIGH GROUNDWATER COMPUTATION BASED ON TP#1 DEPTH TO BOTTOM OF HOLE 11.5 SOIL CLASS Permit valid for ItEP,uu 01, SEPTIC SN I I F NI 1 ONL%% due to State and I oeal septir' \a n.uiFrs, Board of Ilrallh review and aplil l is required Inr any fohue• addit uenslre on, IF l inn dal l erations to L.T.A.R. sewage tact Gt ies All d/oF stil l u r es/d Nrll in g. 0.74 G.P.D.,lool T. 1 arnunrlh Ilya It i. Ucpartmc f APPIZ0V 1) 5'ekoll 38" Na c 'l - U INDICATES PERC. TEST ®INDICATES UNSUITABLE MATERIAL INDICATES ESTIMATED SEASONAL HIGH GROUND WATER INDICATES OBSERVED GROUND WATER DATUM: BOX DETAIL: TOP OF FOUNDATION VERTICAL DATUM: ASSUMED A 4" INVERT AT BUILDING BENCH MARK SET: TOP OF CONCRETE FOUNDATION 4" INVERT AT ADDITION 78.70 ELEVATION 81.67 4" INVERT AT SEPTIC TANK (IN) 77.70 PROFILE: NOT TO SCALE 77.45 D EL= A TOP�TION 77.27 E FIRST PIPE LENGTH 77.10 CONCRETE COVERS TO WITHIN INVERTS AT LEACHING FACILITY: TO BE SET LEVEL EL= 81.00 6' OF FINISHED GRADE.7/ 0 oo° FOR MIN. 2' OF LEACHING CHAMBER 77.00 G BREAKOUT 77.50 FINISH GRADE OVERLAY DISTRICT: NONE OF LEACHING CHAMBER EL= 80.7-80.! C.O. NO OBSERVED GROUNDWATER 4' PVC SCH 40 BOTTOM OF HOLE 69.7 J PANEL #250015 0004 C (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN __ 411l '�' ..� -LEACHING CHAMBER 000 0 0 00 0 0 10'-B1 31'-82 INFI TRATOR 3050 o o° 0 0 0 0 0 0 00 0 0° 5' I=D DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE 4• Jill 0°00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I=C AND STRUCTURES AS REQUIRED PRIOR I=E N8, H SHALL APPLY. 5 OUTLET 1=F A GARBAGE GRINDER IS NOT DIST. BOX •. 5,5" OUTLETS 5.3' SEPARATION 2. PROVIDE INLET TEE OR BAFFLE WHERE . SEPTIC TANK 15' 2' + 15' 1.5' FACILITY. EST. HIGH GROUNDWATER THE CONTRACTOR PRIOR TO CONSTRUCTION. SLOPE OF PIPE EXCEEDS 0.06 FT./FT OR !- J INVERT ELEVATIONS: BOX DETAIL: TOP OF FOUNDATION 81.67 A 4" INVERT AT BUILDING 79.97 B1 ADD 4 BAND S.S. CONN. 4" INVERT AT ADDITION 78.70 B2 4" INVERT AT SEPTIC TANK (IN) 77.70 C 4" INVERT AT SEPTIC TANK (OUT) 77.45 D 4" INVERT AT DIST. BOX (IN) 77.27 E 4" INVERT AT DIST. BOX (OUT) 77.10 F INVERTS AT LEACHING FACILITY: 1 MINIMUM LOT SIZE: 4" INVERT AT BEGINNING 0 oo° 9,3991 S.F. OF LEACHING CHAMBER 77.00 G BREAKOUT 77.50 ELEVATION AT BOTTOM OVERLAY DISTRICT: NONE OF LEACHING CHAMBER 75.00 H NO OBSERVED GROUNDWATER FEMA FLOOD 4 UNITS BOTTOM OF HOLE 69.7 J VARIANCES REQUESTED: TI TLE 5: (1.) TO ALLOW THE LEACHING FIELD TO BE 16.8' FROM THE NEW FULL FOUNDATION WALL IN LIEU OF 20' (2.) TO ALLOW THE SEPTIC TANK TO BE 6.1' FROM THE NEW FOUNDATION WALL IN LIEU OF 10' FLOOR PLANS: SEE ATTACHED ARCHITECTURAL PLANS SEPTIC TANK DETAIL: 1,500 GALLON NOT TO SCALE NOTES. 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, REINFORCED CONCRETE. SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE. III TANK TO WITHSTAND H-10 LOADING TEES TO BE CENTERED UNDER MANHOLE COVER. UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS, WHEREIN H-20 LOADING SHALL APPLY. 3. ALL PIPE CONNECTIONS AND CONCRETE 2-24• DIA CONCRETE MANHOLES CONSTRUCTION SHALL BE WATERTIGHT. W/ METAL HANDLES BROUGHT 4. FILL ALL UNUSED KNOCKOUTS WITH TO 6" OF FINISH GRADE MORTAR. TEE TO BE UNDER M.H. OPENING COVER MIN. RAISE III W� �•--- 10'-6" SEWER BRICK 7- i cr-o" 10'-0' &MORTAR „ NORMAL WATER LEVEL 12 __T -a3` _ PRECAST SEPTIC TANK a 100 14 INLET TEE DO (D c -L-25'-2" 4'-6' 4'-0" MIN. or eoto a 5'-8" 9 LIQUID DEPTH :. a BOTTOM ON LEVEL STABLE BASE 4 PLAN VIEW 6" MIN. 3/4" TO��`��`� 1 1/2" STONE CROSS-SECTION VIEW LOT #51 rr- 4' DISTRIBUTION BOX DETAIL: NOT TO SCALE GENERAL NOTES: 0 00 0 000 000 0 0 0 0 0 0 0 000 0000 0 0 0 0 0 0 NO. OF OUTLETS: 5 LEACHING DETAIL: 4" PVC PIPE l NOT TO SCALE h- 2 PLAN VIEW LOT #52 N31'48'20"W / of ` f NOTE, o 811 _ AREAS OF ADDITIONS THAT ARE ' LISTED AS (SLAB/CRAWL) HAVE THE tri Z CRAWL SPACE FLOOR ABOVE THE 0 TOP OF THE LEACHING SYSTEM, 10.01 W a p PROPOSED 8,2'x 35' le - ^ LEACHING S.A.S. RPOSED to - / INSPEC ION PORT PROPOSED 'D' BOX „ I BULKHEAD PI�fIPOSED CO. 6 PROPOSED 1500 C 218, PPORCH o GALLON SEPTIC TANK a TP#1 24" o PROP, 62 II I "i ADDITION \ \ BO o, I ADDITION m (FULL) (CRAWL/SLAB) t GAS AS I \ i I KITCHEN BATH I rn \ BED#3 O BED#1 EXISTING 3 oW I I PROP. BEDROOM DWELLING ADDITION v I I (CRAWL) P ua0i I �� I LIVING ROOM 3 m Z I\ I BED#2 g O / r i PORCH in I CONCRETE STOOP 16.6 - - _ _.I W W W / i o \\ 011 \ Iso ti N LOT #50 `,� I M � LOT #48 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR.o° FINISHED GRADE o 0 0 0 0 0 0 0 0 0 0 00o° 00°0 000 0°0 HIGH 000 O OS DENSITY p p 000 POLYETHYLENE O O QDO p INFILTRATOR 3050 00 p 00 CHAMBER 0 0 3' LAYER PEASTONE GENERAL NOTES: 0 00 0 000 000 0 0 0 0 0 0 0 000 0000 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 JOSEPH & ALICE SHERMAN F ABLE PLAN REFERENCE: 2• WALLS NOTES 58 °° 0 ° OBS. PORT ZONING DISTRICT: °° o °° 0 00 T IMPERVIOUS MATERIAL SIDE 15' CLEAN GRANULAR SAND, FREE FROM ORGANIC 1 MINIMUM LOT SIZE: 25,000 S.F. 0 oo° 9,3991 S.F. EX. LOT COVERAGE: 0 °7 O ° o° 50" 98" OVERLAY DISTRICT: NONE .a'Q••'.v•a,it••'.v'a••••i•a • 2 1. DIST. BOX TO WITHSTAND H-10 LOADING ZONE: ° FEMA FLOOD 4 UNITS HIGH DF,NSITY 0 0 LE SIZE) 0.15 trimPASS PANEL #250015 0004 C (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN j I UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING SIBLE FOR PROPERLY LOCATING AND 000 0 0 00 0 0 POLYETHYLENE 0 0 0 0 0 0, INFI TRATOR 3050 o o° 0 0 0 0 0 0 00 0 0° EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL 0°00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i AND STRUCTURES AS REQUIRED PRIOR 1 N8, T 150 SHALL APPLY. TME USE OF A GAK3AGE GRINDER. A GARBAGE GRINDER IS NOT 6' •. 5,5" OUTLETS ;, 8• 1 2. PROVIDE INLET TEE OR BAFFLE WHERE 1.5' 15' 2' + 15' 1.5' FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. SLOPE OF PIPE EXCEEDS 0.06 FT./FT OR !- ANY FIELD CHANGES THAT MAY BE 35' ;:i BSC GROUP 349 Main Street, (RT. 28) Unit D �ea b9� "•e o °�` 4°�gIN PUMPED SYSTEM. 508 778 8919 PLAN VIEW - LEACHING CHAMBERS SEWAGE DISPOSAL SYSTEM REPAIR WITH BOTTOM ON LEVEL 2 3. FIRST TWO FEET OF PIPE OUT OF DIST. WEST YARMOUTH MASSACHUSETTS PREPARED FOR: SCOTT BUCKLEY P.O. BOX 1925 COTUIT, MA 02648 STABLE BASE 6" MIN. 3/4" TO 1 112" CRUSHED BOX TO BE LAID LEVEL COMP. DESIGN: K. HEALY LOAM & SEED DISTURBED AREAS FIELD: D. GAZZOLO / N. MERCIER FILE NO. 9283-SEP.DWG DWG NO. 5850-01 CROSS-SECTION S70NE BASE 4 ALL PIPE AND ETE CONSTRUCTIONNECTIONS SHALL BE WATERTIIGHT.11111111777777777777,11114-111111111111111111177777777 3' MAX. COMPACTED FILL 36"1 1 MAXIMUM 12"MIN MUM h- 2 PLAN VIEW LOT #52 N31'48'20"W / of ` f NOTE, o 811 _ AREAS OF ADDITIONS THAT ARE ' LISTED AS (SLAB/CRAWL) HAVE THE tri Z CRAWL SPACE FLOOR ABOVE THE 0 TOP OF THE LEACHING SYSTEM, 10.01 W a p PROPOSED 8,2'x 35' le - ^ LEACHING S.A.S. RPOSED to - / INSPEC ION PORT PROPOSED 'D' BOX „ I BULKHEAD PI�fIPOSED CO. 6 PROPOSED 1500 C 218, PPORCH o GALLON SEPTIC TANK a TP#1 24" o PROP, 62 II I "i ADDITION \ \ BO o, I ADDITION m (FULL) (CRAWL/SLAB) t GAS AS I \ i I KITCHEN BATH I rn \ BED#3 O BED#1 EXISTING 3 oW I I PROP. BEDROOM DWELLING ADDITION v I I (CRAWL) P ua0i I �� I LIVING ROOM 3 m Z I\ I BED#2 g O / r i PORCH in I CONCRETE STOOP 16.6 - - _ _.I W W W / i o \\ 011 \ Iso ti N LOT #50 `,� I M � LOT #48 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR.o° TO 30 „ „ 24 EFFEC. DEPTH o 0 0 0 0 0 0 0 0 0 0 00o° 00°0 000 0°0 HIGH 000 O OS DENSITY p p 000 POLYETHYLENE O O QDO p INFILTRATOR 3050 00 p 00 CHAMBER 0 0 3' LAYER PEASTONE GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND \\ FACILITY & THE BUILDING ADDITION ONLY. CURRENT OWNER: JOSEPH & ALICE SHERMAN 24" 50" 24" 3/4" - 1 1/2" WASHED STONE - 980 CROSS-SECTION OF CHAMBER DESIGN CRITERIA: PUMP, CRUSH AND REMOVE L O T #53 rDESIGN FLOW: ALL EXISTING SEPTIC COMPONENTS IN ACCORDANCE 3 BEDROOMS AT 110 G.P.B./D 330 G.P.D. WITH TITLE S. 0A ; �' L❑T #49 I ° I I WORK MUST ,{r��CpONF�O(FRIlIA�TO ALL TMIM AND REGLILAIIViS POST & RAIL FENCErn %G, 11/� N31'48'20'W YARAOU" WATER DEPT I (Y',TE 94.0 oHw g0 _ OHW oFnv�_ - - - - - - - - - - - - 1•- _- _ _ - -L _ _ _ _ - ¢-wglEg MAIN _ _ I--'-� oHw oHw QHw f�r-L _ OHw ------------ -W - - -- 1 I t1 0F41q GROUSEoaa� �yG of LANE 1 .S BRIAN a YERGATIAN NIL FOD 1 y 2060 KIM 38M -' ---------------------_ - - - - -- _ - _ - 1 � •pN _ a FFSS� \ I/wA rLol r 013 I1 PLAN VIEW SCALE: 1' = 10 FEET 0 5 10 20 FT, REQUIRED SEPTIC TANK: 330 X 200% = 660 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <2 MIN./ INCH LONG TERM APPL. RATE 0,74 G.P.D/S.F. 330 GPD + 0,74 GPD/SF = 446 S.F. SIZE OF LEACHING FACILITY PROVIDED: USE HIGH DENSITY POLYETHYLENE LEACHING CHAMBERS(4 UNITS) 8,17'X2'X35' SIDEWALL = 2(8,17'+35') X 2' = 172,68 BOTTOM = 8,17' X 35' = 285,95 _-- 458,6S,F, 458.6 S,F x 0,74 GPD/SF = 339GPD LOCUS PLAN: NO SCALE N Q\ p LOCUS BUCK ISLAND ROAD GROUSE LANE 3 4 3 REVISIONS LOCUS INFORMATION 2. 10/3/12 MODIFY ADD. GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY & THE BUILDING ADDITION ONLY. CURRENT OWNER: JOSEPH & ALICE SHERMAN TITLE REFERENCE: BOOK 1328, PAGE 65 PLAN REFERENCE: L.C. PLAN 32827-A, SH -3 ASSESSORS MAP: 58 PARCEL: 396 ZONING DISTRICT: R-25 SETBACKS: FRONT 30' IMPERVIOUS MATERIAL SIDE 15' CLEAN GRANULAR SAND, FREE FROM ORGANIC REAR 20' MINIMUM LOT SIZE: 25,000 S.F. EXISTING LOT AREA: 9,3991 S.F. EX. LOT COVERAGE: 1,306± S.F. (13.97.) PROP. LOT COVERAGE: 1,896± S.F. (20.27) OVERLAY DISTRICT: NONE NITROGEN SENSITIVE MATERIAL MEETS EACH OF THE FOLLOWING ZONE: NOT A ZONE II FEMA FLOOD 10%100% MUST PASS #50 SIEVE ZONE DISTRICT- "C" DATED 6/17/1986 LE SIZE) 0.15 trimPASS PANEL #250015 0004 C LOCUS PLAN: NO SCALE N Q\ p LOCUS BUCK ISLAND ROAD GROUSE LANE 3 4 3 REVISIONS NO. DATE DESCRIPTION 1. 11/1/07 REDUCE ADD. 2. 10/3/12 MODIFY ADD. GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY & THE BUILDING ADDITION ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL 6. REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A #4 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL UP TO 45% BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 10%100% MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) O%-20% MUST PASS #100 SIEVE LE SIZE) 0.15 trimPASS 0%(-5% MUST 0 SREVEE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. N8, Tr+IS SYSTEM IS NOT DESIGNED FOR TME USE OF A GAK3AGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONFIRM LOCATION & NUMBER OF INVERTS. 0. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. ;:i BSC GROUP 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR WITH BUILDING ADDITION #8 GROUSE LANE WEST YARMOUTH MASSACHUSETTS PREPARED FOR: SCOTT BUCKLEY P.O. BOX 1925 COTUIT, MA 02648 SCOTT.WB®LI VE. COM (508) 367-2530 DATE: OCTOBER 11, 2007 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D. GAZZOLO / N. MERCIER FILE NO. 9283-SEP.DWG DWG NO. 5850-01 SHEET 1 OF 1 JOB NO. 4-9283.00