Loading...
HomeMy WebLinkAbout52 Harbour Hill Run Site and Sewage PlanASSESSORS MAP. 911_ PARCEL: 164 N �L"sTECURRENT ZONING: R-40 (1958 SUBDIVISION) BUILDING SETBACKS: L7e- F: 30 S: 6 R: 20 FLOOD ZONE: C � BASS RIVER LOCATION MAP LOT 48 10,120 ± S.F. (023 ± AC.) Ad�L1 10' 193 33.4 KEY: EXISTING CONTOUR:. - - - PROPOSED CONTOUR: • • • • • . • • . . . ........ EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25 TEST HOLE: -$)- UTILITY POLE: -0- FENCE LINE: - HYDRANT: -6 RETAINING WALL: 31.2 TH-1 1 G1 ,32 a Z 30.0 1` C f � ELEV. 1 A HORIZON A HORIZON s3 r LOAMY SAND ss1 m 1 I{1 IOYR 5/3 0 `O I i 31.r J 32. 7 i T ES7 MULE LOGS ENGINEER: DAVE MASON, R.S. WITNESS: KELDA WELSH DATE: 7-10-99 PERCOLATION RATE: < 2 MIN/IN NO GROUND MATER ENCOUNTERED NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NCVD +/-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH= 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0'. 11. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 12. ALL UNSUITABLE SOIL (B HORIZON, APPROX. 43" DEEP)) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. SEPTIC SYSTEM DESIGN FLOW ESTIMATE: -4-_ BEDROOMS AT _110 GAL/DAY/BEDROOM = 440 GAL/DAY SEPTIC TANK: 440 GAL/DAY x 2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 PRECAST 500 GALLON CHAMBERS (8.5' x 4.8' x 2' DEEP) WITH 4' OF STONE ALL AROUND. (33.6'x 12.8'x 2' DEEP) SIDE AREA.- 146.3) 2 x 2 = 185 SF (.74) = 137 GAL/DAY BOTTOM AREA: 33.5' x 12.8' = 429 SF (74) = 317 CAL/DAY CAPACITY = 454 CAL/DAY (RESERVE: LEACH TRENCH (74' x 4' x 2' DEEP) CAPACITY = 449 CID) SEPTIC SYSTEM SECTION 36.5 TOP OF FOUNDATION 27.3 1500 CAL ELEV. SEPTIC TANK 27 5 (6" OF STONE UNDER OR ELEV. MECHANICALLY COMPACTED) (UNDER SLAB) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN TREE:{ •; DDM EST-McLvf-L_:.:' , i� a NGI Ne'ERI NG 24 SCHOO- .., aEET PA. BOX 4G 1 WEST DENNIS, MASSACHUSETT! 02670 DM # s9,4�i PHONE & FAX :(508) 398-7710 COVERS WITHIN 1Z" OF FINISHED GRADE ME INSPECTION COVER BE WITHIN 6" OF GRADE) WALK -OUT 36' 14' r DECK PORCH 9' 19 w v PROPOSED 4, 4 BEDROOM DWELLING 26'64 28' < o V sx r 14' 7' 6. PORCH 3T PROPOSED DWELLING 2" PEASTONE 314--1 1/2" WASHED STONE / ELEV: 27.5 27.05 ELEV. D -BOX e ® 24.64 26.82 ELEV. 26.99 (6" OF ELEV. 26.64 4 4 ELEV. STONE ELEV. E 33.5' UNDER) USE 3 PRECAST 500 GALLON CHAMBERS (8.5' x 4.8' x 2' DEEP) G OUTLET EE WITH 4' OF STONE ALL AROUND. (33.5 x 12.8'x Z DEEP) AT (4" PVC PIPE TO BE USED BETWEEN CHAMBERS) SITE AND SEWAGE PLAN APP OVED BY: DATE: LOCATION.' 52 HARBOUR HILL RUN OF b1arW Q ` .ASN, YARMOUTH, MA f JaiN M'r i a„ ' m �_ a4r.. ; � o z. � ; i PREPARED FOR v Fx} x`14 �� n , DEMAREST, JR. " a' No. 36859 STEVE POWERS ess% ? � SCALE: !" = 20' DATE: 0811319 REFERENCE: LAND COURT CASE 17002E SHEET 2 REVISED: B-26-99 REVISED: B-31-99 (POOL) THOMAS MCLELLAN, P.E. JOHN Z. DEMAREST JR., P.L.S. REVISED: 9-30-99 (NEW HOUSE & POOL) TH-1 TH-2 31.0 30.0 ELEV. ELEV. A HORIZON A HORIZON LOAMY SAND LOAMY SAND 6" IOYR 5/3 30.5 9" fOYR 4/3 Bw HORIZON 298 Bw HORIZON LOAMY SAND LOAMY SAND 32" 10YR 6/8 28.3 43" fOYR 5/6 C HORIZON 26.4 C HORIZON FINEFIN6 SAND FINEFINE SAND 2.5Y 7/6 2.6Y 7/4 120" 21.0 132' 190 NO GROUND MATER ENCOUNTERED NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NCVD +/-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH= 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0'. 11. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 12. ALL UNSUITABLE SOIL (B HORIZON, APPROX. 43" DEEP)) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. SEPTIC SYSTEM DESIGN FLOW ESTIMATE: -4-_ BEDROOMS AT _110 GAL/DAY/BEDROOM = 440 GAL/DAY SEPTIC TANK: 440 GAL/DAY x 2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 PRECAST 500 GALLON CHAMBERS (8.5' x 4.8' x 2' DEEP) WITH 4' OF STONE ALL AROUND. (33.6'x 12.8'x 2' DEEP) SIDE AREA.- 146.3) 2 x 2 = 185 SF (.74) = 137 GAL/DAY BOTTOM AREA: 33.5' x 12.8' = 429 SF (74) = 317 CAL/DAY CAPACITY = 454 CAL/DAY (RESERVE: LEACH TRENCH (74' x 4' x 2' DEEP) CAPACITY = 449 CID) SEPTIC SYSTEM SECTION 36.5 TOP OF FOUNDATION 27.3 1500 CAL ELEV. SEPTIC TANK 27 5 (6" OF STONE UNDER OR ELEV. MECHANICALLY COMPACTED) (UNDER SLAB) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN TREE:{ •; DDM EST-McLvf-L_:.:' , i� a NGI Ne'ERI NG 24 SCHOO- .., aEET PA. BOX 4G 1 WEST DENNIS, MASSACHUSETT! 02670 DM # s9,4�i PHONE & FAX :(508) 398-7710 COVERS WITHIN 1Z" OF FINISHED GRADE ME INSPECTION COVER BE WITHIN 6" OF GRADE) WALK -OUT 36' 14' r DECK PORCH 9' 19 w v PROPOSED 4, 4 BEDROOM DWELLING 26'64 28' < o V sx r 14' 7' 6. PORCH 3T PROPOSED DWELLING 2" PEASTONE 314--1 1/2" WASHED STONE / ELEV: 27.5 27.05 ELEV. D -BOX e ® 24.64 26.82 ELEV. 26.99 (6" OF ELEV. 26.64 4 4 ELEV. STONE ELEV. E 33.5' UNDER) USE 3 PRECAST 500 GALLON CHAMBERS (8.5' x 4.8' x 2' DEEP) G OUTLET EE WITH 4' OF STONE ALL AROUND. (33.5 x 12.8'x Z DEEP) AT (4" PVC PIPE TO BE USED BETWEEN CHAMBERS) SITE AND SEWAGE PLAN APP OVED BY: DATE: LOCATION.' 52 HARBOUR HILL RUN OF b1arW Q ` .ASN, YARMOUTH, MA f JaiN M'r i a„ ' m �_ a4r.. ; � o z. � ; i PREPARED FOR v Fx} x`14 �� n , DEMAREST, JR. " a' No. 36859 STEVE POWERS ess% ? � SCALE: !" = 20' DATE: 0811319 REFERENCE: LAND COURT CASE 17002E SHEET 2 REVISED: B-26-99 REVISED: B-31-99 (POOL) THOMAS MCLELLAN, P.E. JOHN Z. DEMAREST JR., P.L.S. REVISED: 9-30-99 (NEW HOUSE & POOL)