Loading...
HomeMy WebLinkAbout30 & 32 Headwaters Drive - Site PlanGENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT, FOR LOCATION OF UNDERGROUND UTILITIES. 8. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT, 9. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 10. ROOF RUNOFF TO BE DIRECTED TO DRYWELLS OR A STONE TRENCH ALONG THE DRIP LINE. ACCESS COVERS MUST BE WITHIN 6' OF FINISH GRADE 3 FIRST 2' TO BE LEVEL I, ` GAS / 95 55 LJ$ 95. n I 10* 0 III Z194.1 BAFFLE / 3 OUTLET 5 HIGH CAPACITY INFILTRATOR P ° D -BOX CHAMBERS W13.5't STONE AROUND 1500 GAL 110'r X 38'1 X IO'd SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROF I L E: NOT To SCALE 9' MINIMUM. 3' MAXIMUM COVER MIN 2' OF PEASTONE 3/4' - 1112' DIA. DOUBLE WASHED STONE INVERT ELEVATIONS INVERT AT BUILDING: 96.0 INVERT IN SEPTIC TANK: 95.8 INVERT OUT SEPTIC TANK: 95.55 INVERT IN DIST. BOX: 95.47 INVERT OUT DIST. BOX: 95.3 INVERT IN LEACH CHAMBER: 95.0 BOTTOM OF LEACH CHAMBER: 94.17 ADJUSTED GROUND WATER: NIA OBSERVED GROUND WATER: NIA BOTTOM OF TEST HOLE •1: 86.5 DESIGN CRITERIA DESIGN FLOW: 3 BEDROOMS AT IIO G.P.D. PER BEDROOM EOUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REOUIREO: 330 G. P. D. X 200x - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN, SOIL ABSORPTION SYSTEM REOUIRED: DESIGN PERC RATE ( 5 MINIINCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPDISF 330 GPD / 0.74 GPDISF - 446 S.F. REOUIRED PROVIDED: 5 HIGH CAPACITY INFILTRATOR CHAMBERS W13. 5'± STONE AROUND. A-460 S.F. 340 GPD 0 10 20 40 z Nm NO SE O r GOND v ppGK ISLA p0AD BIG SANDY c = D PD xf Locus A h Oi h M 9�GtF �e V U J LOCUS MAP ASSESSORS MAP 32, PARCEL H26 ZONING DISTRICT: R-25. MINIMUM FRONTAGE - 150' SETBACKS: FRONT - 30'. SIDE - 15'. REAR - 20' MINIMUM LOT AREA - 25.000 S.F. FLOOD ZONE C. MAP 250015 005 D. DATED 7/2/92 SOIL TEST PIT DA TA e INDICATES INDICATES PERCOLATION _ OBSERVED TEST GROUNDWATER TP #1 TP •2 0' HORIZON TEXTURE COLOR 98.5 0' HORIZON TEXTURE COLOR 98.0 A TOPSOIL FILL ...... ............. .................... Y0 96.3 B SUBSOIL O / r LOAMY IOYR C SAND 212 24' _... ............... ................... 96.5 28 95.7 C I UM -FINE B LOAMY 516YR SANDSAND C I MEDIUM IO YR SAND 614 144' NO WATER 1 86.5 132' 1 NO WATER DATE: OCTOBER 14. 1993 DATE: MARCH 1. 1999 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONEHONE PERC RATE: ! 2 MINIINCH S / 7-E PL,4/V OF_ LAIVO 30 B 32 HEAD WA TERS OR / VE .Wi j S T YOARMOCJTH, "A . PREPARED FOR : ./ EF_ S o L L o WS HER / TA GE REAL TY B DEVELOPMENT. //VO SOALE: / " - 20 ' "ARO" 131 2000 E A G L E S U R V E Y I N G, I NC 923 Route 6A Yormouthport, MA. 02675 ( 508 ) 362-8 1 32 (508) 432-5333 87.0