Loading...
HomeMy WebLinkAbout25 Herveylines Lane Site PlanSYSTEM PROFILE PROVIDE MIN. 20" DAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6' OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE \ _ TOP FOUND. EL. 28.5' FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TYP.) Vol MIN. (__2 % SLOPE) ALL SYSTEM COMPONENTS SHALL BE MARKED -WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE. COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 27.5' BLOCKS OR rj,:4"0,SCH4O PVC -MOR7AR ALL PRECAST RISERS IPLEVEL 1ST 2' Tj COMPONENTS ) H 10 NVS EL 4 10" 1500 GAL H 10 14. ..-. . EL. 25.3' TEE SEPTIC TANK TEE 25.5' ° ��®® O --m Elm GAS It Foo 24.78' 24.61' CME OR EQUAL) Q 99 ;0000�°op000°000, `- H-10 500 GAL LEACHING CHAMBER BY ACME PRECAST OR EQUAL 3/4"-1-1/2" DOUBLE WASHED STONE ALL AROUND PRECAST STRUCTURES (3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 32.50' X 12.83'. COMPACTION. (15.221 [2]) (_L.3 % SLOPE) (-1-5r SLOPE) FOUNDATION- 10' SEPTIC TANK 31, D' BOX 13' FACILITY 17.5' BOTTOM TH-1 & 2 NO GROUNDWATER FOUND _ 'THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND. 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 1OYR 3/2 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE, SE WITNESS: PHIL RENAUD DATE: SEPT. 30, 2009 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS ELEV 1 1 1 1 100.0 /J� I I 0.56 v 1 6 J� If n^ U i� ! 23.6 Q z ELEV. 0" 27.5' 0" 27.5' W\w i Scale: 1"= 20' 0 10 20 30 40 50 FEET PCI trp ,Wir i PORCH EXIST. DWELL. TOP FNDN. _ 20 28.5' GARAGE UNDER PROPOSEC ADDITION (CRANLSPJ M16 h/ e LARGE OAKS NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 0/A 12" FI LL A/B LS 1OYR 3/2 LS 1OYR 3/1 3" 14" E E FS FS 10YR 5/2 10YR 5/2 8" 18" B B LS LS 381, 10YR 5/6 24.3' 46" 10YR 5/6 23.6' C C PERC FS FS 2.5Y 7/4 2.5Y 7/4 120" 17.5' 120" 17.5' NO GROUNDWATER ENCOUNTERED 09-063 W\w i Scale: 1"= 20' 0 10 20 30 40 50 FEET PCI trp ,Wir i PORCH EXIST. DWELL. TOP FNDN. _ 20 28.5' GARAGE UNDER PROPOSEC ADDITION (CRANLSPJ M16 h/ e LARGE OAKS NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & NOT TO SCALE OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 59 PARCEL 16 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE "C" PROPOSED LEACHING FACILITY. AS SHOWN ON COMMUNITY PANEL#250015 0004C 12. EXISTING LEACHING FACILITY SHALL BE PUMPED DATED 6/17/86 AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. SITE IS NOT WITHIN AN APD 13. WATER TEST D'BOX FOR LEVELNESS. REF: DB 10794 PG. 130 PB 174 PG. 31 & CTF 144743 LCP 28410-F EXIST. INVERT - OUT EL. 26.0'± 7 8 ST r 0IAD£ F£k o, X 7.17 `\ CRAWLSP. `zs \.2 -89 LOTS 31 & 31A 55 12,161± SF 27.41 -27. 7 I;CP) p X .67 o /O, O BENCH MARK - TOP OF 0 3j 1 CONIC. FNDN. ELEV. - 28.5 4 7* 81 � Y 7x 7.56 Al o P �x / C2am; r" / r° / 27.73 U ! 7 Jz >€;1 P .0N"FM TO AjL TBP'^ GYLA,\S AND REGLuT e_t'MOUTI!d�WATF9 �- J 13EP7 ; 7.10 61 GARDEN .22 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) k O-\-0' DATE SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (32.5 + 12.83) 2 (.74) = 134.2 GPD BOTTOM 32.5 x 12.83 (.74) = 308.5 GPD TOTAL: 598 S.F. 442.7 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AT SIDES AND 3.5' AT ENDS , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF -1 DANIEL A. OJALA, P.E., P.L.S. 25 HERVEY LINES LANE SOUTH YARMOUTH PREPARED FOR ROBERT WELCH OCTOBER 1, 2009 off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 09-063.DWG(SBO) HLE GuPY IM 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & NOT TO SCALE OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 59 PARCEL 16 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE "C" PROPOSED LEACHING FACILITY. AS SHOWN ON COMMUNITY PANEL#250015 0004C 12. EXISTING LEACHING FACILITY SHALL BE PUMPED DATED 6/17/86 AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. SITE IS NOT WITHIN AN APD 13. WATER TEST D'BOX FOR LEVELNESS. REF: DB 10794 PG. 130 PB 174 PG. 31 & CTF 144743 LCP 28410-F EXIST. INVERT - OUT EL. 26.0'± 7 8 ST r 0IAD£ F£k o, X 7.17 `\ CRAWLSP. `zs \.2 -89 LOTS 31 & 31A 55 12,161± SF 27.41 -27. 7 I;CP) p X .67 o /O, O BENCH MARK - TOP OF 0 3j 1 CONIC. FNDN. ELEV. - 28.5 4 7* 81 � Y 7x 7.56 Al o P �x / C2am; r" / r° / 27.73 U ! 7 Jz >€;1 P .0N"FM TO AjL TBP'^ GYLA,\S AND REGLuT e_t'MOUTI!d�WATF9 �- J 13EP7 ; 7.10 61 GARDEN .22 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) k O-\-0' DATE SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (32.5 + 12.83) 2 (.74) = 134.2 GPD BOTTOM 32.5 x 12.83 (.74) = 308.5 GPD TOTAL: 598 S.F. 442.7 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AT SIDES AND 3.5' AT ENDS , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF -1 DANIEL A. OJALA, P.E., P.L.S. 25 HERVEY LINES LANE SOUTH YARMOUTH PREPARED FOR ROBERT WELCH OCTOBER 1, 2009 off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 09-063.DWG(SBO) HLE GuPY