Loading...
HomeMy WebLinkAbout407 Highbank Road Proposed Septic Design 4A HORIZ 3.0' COLOR CLEAN SAND WASHED STONE ®•-- PROPOSED CONTOUR .. T - P OF FOUNDATION : 20 FT. MINIMUM FROM FOUNDATION MAX.' - SOIL - EST ROOTS �. COR EQUAL) MINIMUM E EV.= 36.00 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE _ - DATE OF SOIL TE57. Sat TEST DONE 8Y, 1-17-01 1ou.°1T`,.R OiG70�W I COARSE SAND tOYR 6/6 52'-120' . C2 MEDIUM SAND ���+��� - 1d:1.9iJiilli[ MTNES= Br, - .. A. VON HONE i 235 GREAT WESTERN ROAD j:. " ELEV.= 33.00 10. 31.00 I CU. FT.. OF CONCRETE ANCHOR WATER SHUT OFF VALVE COBBLE Ot 506-398-3922 ta.. 508-3941-3063 CONCRETE COVERS LEv.= 31_75 2 0• x 706 EXISTING SPOT GRADE OBSERVATION HOLE: 1 ' ELEV.- 30.00 ELEV.= 32 00 GAS ELEV. LEVEL BAFFLE 6' SUMP 10 JC6NQ. 5033 LOCUS MAP 31.00 ELEV.® 30.83 = �� CLEAN OUT 4" SCHEDULE 40 PVC PI MIN. PITCH 1/8- PER FT. / 2" LAYER OF LOAM AND UB' TO 1/2' -E6- EXISTING CONTOUR PERCOLATION 1 RATE <2 MIN: INCH 0 52 { / I A HORIZ 3.0' COLOR CLEAN SAND WASHED STONE ®•-- PROPOSED CONTOUR .. I 4' CAST IRON PIPE MAX.' a/ PROPOSED SPOT.GRADE � NO ROOTS �. COR EQUAL) MINIMUM VENT - - 34.00 MAXVENTCHI t0YR,5/8 407 HIGHBANK ROAD PITON 1/4 PER FT, 36'-5r, SOIL TEST LOCATION COARSE SAND tOYR 6/6 52'-120' . C2 MEDIUM SAND IOYR 7/6 i -4_& WATER UNE 235 GREAT WESTERN ROAD j:. " ELEV.= 33.00 10. 31.00 I CU. FT.. OF CONCRETE ANCHOR WATER SHUT OFF VALVE COBBLE Ot 506-398-3922 ta.. 508-3941-3063 LEv.= 31_75 2 0• EXISTING GAS UNE DATE: 1-26-01 SCALE 1.'-20' ELEV.= 32 00 GAS ELEV. LEVEL BAFFLE 6' SUMP 10 JC6NQ. 5033 LOCUS MAP 31.00 ELEV.® 30.83 = �� CLEAN OUT ' " ° SHEET 1; OF 1 _ _ ' ELEV.- 29.87 DISTRIBUTION C.P.O CESSPOOL CTO BE PLACED ON FIRM BOX DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0'-12 A/P LOAMY SAND 10YR 2/2 NO ROOTS 12'-36" 8 LOAMY SAND t0YR,5/8 407 HIGHBANK ROAD 36'-5r, Cl COARSE SAND tOYR 6/6 52'-120' . C2 MEDIUM SAND IOYR 7/6 40% 235 GREAT WESTERN ROAD PO BOX 713 SOUTH DENNIS, MA 02660 COBBLE i i i LI.UID OUTLET BSE) DEPTH TEE TO BE WATER TESTED 4 HIGH CAPACITY INFILTRATORS NO 7=9 -ENCOUNTERED AT 120' ELEV.- 2000 H -(LO) (TO BE PLACED ON FIRM BASE) WITH STONE IN AN 11' X 36' X 10' O CATCH BASIN ' 4 FEET 14 INCHEg 5 FEET 19 INCHES I5OO GALLON TRENCH FORMATION WELL N A 6 FEET 24 INCHESELEV.= w 7 FEET 29 INCHES SEPTIC . TANK 30.50 ZONE DESIGN CALC; 11;ATION S. I -3/4" TO 1 1 2" N -C20) _ ADJUST NUMBER OF BEDROOMSi 3 L/ SOIL ABSORPTION CLEAN DOUBLE GARBAGE DISPOSAL UNIh _.ISO.- j _ . DI PO= SIST6 I PROFILE WASHED STONE SYSTEM (SAS) 9.6T TOTAL ESTIMATED FLOW i FREE OF FINES (110 CAL./BR./DAY X 3 BR.) 330 AND SILTS REQUIRED SEPTIC TANK CAPACITY: GAL/DAY I +Y A (NOT TO SCALE GAL ACTUAL SIZE OF SEPTIC TANK: GAL SOIL CLASSIFICATION:" t USGS PROBABLE WATER TABLE ELEV.= DESIGN PERCOLATION RATE:. MIN./IN. OBSERVED WATER TABLE (11/4/00) ELEV.=EFFLUENT LOADING RATE: GALVDAY/S.F., i BOTTOM OF TEST HOLE ELEV.= 20..00 LEACHING AREA: 474.33 SQ. F.T. (11 x36)+(47X2X 10/12) j LEACHING .CAPACITY (AREA X RATE): 351.00 GAL./ DAY t1t 474.33 X 0.74 " SPIKE' NAIL RESERVE LEACHING CAPACITY: 351,00 GAL /DAY ELEVATION- 28.2' (NGVD) T.T�+T+�� 21.9 - NOTES:. \ 10. EXISTING DWELLING, SEPTICS AND UTIUTIES ARE TO BE REMOVED. 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. i I 11. ALL DISTURBED AREAS ARE TO BE 1REVEGETATED. TITLE 5 AND THE TOWN OF 1;1,1=111111 ULES AND REGULATIONS I I FOR THE SUBSURFACE DISPOSAL OF SEWAGE i COASTAL BANK 12 GUTTER, DOWNSPOUTS AND ORYWELLS REQUIRED. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN \ 13 A VARIANCE OF 4' IS REQUIRED FOR THE TOP OF FOUNDATION TO BE V OF FINISHED GRADE ) I V4245 LESS THAN 2' ABOVE HIGH POINT IN ROAD. 3 ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING28.2 H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR �!, I 14. A NEGATIVE GRADE OF 3/4• PER FOOT SHALL BE MAINTAINED FOR A PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF WAIVOUT'k& �' - MINIMUM OF 15' AWAY FROM THE FOUNDATION. - DRIVES OR PARKING AREAS. EIE0 0 41 ` 0 18,6 7 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MGRTAR_DyN AACE N DROYWP.ELL f y` ` 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR I p 1 ZONING REGULATIONS. INNER/APPUCANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 34.81 t \ 19.7 6. UTIUTIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL j (E)(IST(NO •DIGSAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK PROPOSED 1500-y. GRASS) ON SITE GAL SEPTIC TANKS s�, a� 7. CONTRACTOR TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS I GARAGE VENT i HAYBALES o PRIOR TO COMMENCING WORK -ON SITE ANY -VARIATION IS:.TQ BE.@ROUG}1T I 1 OH -1 ` A RKUMIT o• TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. I � R y 20.9 8. PARCEL. LS IN FLOOD ZONE C � ! 34.9 y U ,O 9. LOT IS SHOWN ON ASSESSORS MAP 1�' ,AS PARCEL i I f 35.0 i 30.5 X 31.0 Wp i x 31.7 I' PROPOSED 3 BEDROOM < S DUMAS 63.4' �P.WELUNG TOFa36.00 619 32.1, X 32.0 o� APPROVED HOARD OF HEALTH I AL _ X 39.0 ITAR11'�' Y -i i - I DATE AGENT ): `! 34.8( PROP. 5.8 ANG 3 9E0 j7.b0 x D -BOX/ EX15 G SOf 500. RE �o x 2j 9 DSO RON1;p is 4.7 33 ASiIARrRVf SO :3 PROP. 5`6� W DRYWII.L , � LOT AREA= ch In 6535 18,681 S.F.t f 37.3 L, �.7 PROPOSED SOIL ABSORPTION R 26.85 - r, _ W 03 p AD SYSTEM. --- 4 HIGH CAPACITY z7.t X3.75 - o R^93.75 36"tI12 INFILTRATORS W/ 4.00' STONE J 6.1 �IGlip Alv. ON THE SIDES AND 3.00' OF STONE rl ON THE ENDS. 36.7 ov SITE PLAN 0 SCALE: 1"=20' • so YARMOUTH, MAPROPOSED SEPTIC DESIGN FOR f DUBLIN CONSTRUCTION k Ro,° r xis _ PLO= 1=710H: 407 HIGHBANK ROAD " i SOUTH YARMOUTH, MA. 02664 / / N SWEETSER ENGINEERING <Rpt� 235 GREAT WESTERN ROAD PO BOX 713 SOUTH DENNIS, MA 02660 Q� Ot 506-398-3922 ta.. 508-3941-3063 DATE: 1-26-01 SCALE 1.'-20' REVI= 1-17-02' JC6NQ. 5033 LOCUS MAP NOT TO SCALE ' " ° SHEET 1; OF 1