HomeMy WebLinkAbout55 Holly Lane - Sewage Disposal SystemSOIL TEST PIT DATA: MAY 30, 2007 SEPTIC TANK DETAIL: 1,500 GALLON DISTRIBUTION BOX DETAIL: NOT TO SCALE LEACHING FIELD DETAIL: NOT TO SCALE NOT TO SCALE N0. OF OUTLETS � 5TEST PIT #L_ NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES BE CAST IRON, FINISHED GRADE 36" MAX .COVER SCHED. 40 PVC OR CAST --IN-PLACE CONCRETE. I GRD. EL. 10.0 REINFORCED CONCRETE. TEES TO BE CENTERED UNDER MANHOLE COVER. REMOVABLE r- 2" WALLS NOTES: FINISHED GRADE 2. SEPTIC TANK TO WITHSTAND H-10 LOADING COVER EST. HIGH GW. 3.9 UNLESS UNDER PAVEMENT, DRIVES OR DATE: TRAVELED WAYS, WHEREIN H-20 LOADING ti;;y„+a;:y+,+q;:y„+,;;:y+;. 2^ 1. DIST. BOX TO WITHSTAND H-10 LOADING ` 5/30/07 T UNLESS UNDER PAVEMENT, DRIVES OR °CAP ENDS SHALL APPLY. } I TRAVELED WAYS WHEREIN H-20 LOADING ' s�p A E 3. ALL PIPE CONNECTIONS AND CONCRETE 4" PVC 4' PE F S 40 C S= 0o5i' �T / HIGH GROUNDWATER COMPUTATION 2-24" DIA CONCRETE MANHOLES e e a , o a e e a e e 4' e qq , CYC 0, e e a e e w e e t0YF7 5/4 TEST BY: CONSTRUCTION SHALL BE WATERTIGHT. W/ METAL HANDLES BROUGHT 1 r. 15" meq, • lteQ. e, ropg LOAMY SAND THE BSC GROUP, INC. (BASED ON TP#1 _F SHALL APPLY. �4N° 4'fi�4a if gJa,4t�$a?fr��a 9f�aot9fagtSPga fi°�4gf �c,ncrTM 4. FILL ALL UNUSED KNOCKOUTS WITH TO 6" OF FINISH GRADE 8' WITNESSED BY: s 6" 2. PROVIDE INLET TEE OR BAFFLE WHERE DEPTH TO WATER. 7_p MORTAR. TEE TO BE UNDER 12" MIN. 6' 5, 5" OUTLETS .. 1 n / AMY VON HONE M.H. OPENING COVER y y , SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR B INDEX WELL MIW_29_ ///� //� t �/ 3" Y�ny fap e�a oa o a oe�a oea �oea j IN PUMPED SYSTEM. LEVEL BOTTOM e� n� -0i X40 4b 4 ��L- 43 a� o 1 OYR 4/6 PERC. RATE: WATER LEVEL RANGE ZONE B 4' BOTTOM ON LEVEL 2" 3. FIRST TWO FEET OF PIPE OUT OF DIST. LOAMY SAND 2 MIN./INCH CURRENT DEPTHONDEX WELL(12/00)-_�_ RAISE M.H W/+ STABLE BASE 6" MIN. 3/4" TO BOX TO BE' LAID LEVEL. PROFILE WATER LEVEL ADJUSTMENT _ 0_9 101-6" SEWER BRICK :.•�•.i:, 1 1/2" C USHED 4, ALL PIPE CONNECTIONS AND CONCRETE ' 32" SOIL EVALUATOR DEPTH TO ADJUSTED HIGH WATER 6_1 10+_0" &MORTAR + 12,. :� 4 CROSS-SECTION STONE BASE CONSTRUCTION SHALL BE WATERTIGHT. EL = 7.33 MARK DIBB NORMAL WATER LEVEL 36" MAX. - 12" MIN. COVER 57 SOIL CLASS: 1 INDICATES �- 73" L. T. A. R. INDICATES -L ESTIMATE) f7 g4" 0.74 G.P.D./SQ.FT. PERC. = SEASONAL HIGH C _ TEST GROUND NATER 10YR 7 3 MEDIUM AND INDICATES ^ INDICATES v_ OBSERVED g^ �: 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. T 14" .' / 2% IIIN. FINISH GRADE � 4" MIN. LOAM &SEED e`- NLET TEE ;S 5'-1" -30 1/2' LOAM & SEED DISTURBED ARE I 5-2" -2 4'-6" 5'-8- ' 3.1 MAXIMUM .e 15MIN 4'-0" MIN. 90'BEND ON 1 �: 15 1/2" :..:.: . , .. ., ... . . Z LIQUID DEPTH OUTIEt TEE (OLS CONTROL) PRECAST DIST. Ij d 2" MIN. OF 1/8- TO i \ 4 a a`ePa 1/2^ WASHED STONE :� 6• °o r'"Pa," e a o + o + (V .. �. BOK � 0 1to�o It'd +o e a .•pew o ac o a /' �,p�e,Pa�? }o�a o 3/4" TO 1-1/2" DOUBLE EL = 0.0 11 120 UNSUITABLE - GROUND 'NATER ,o` Qf 3" �-1 �` WASHED STONE (NO FNES) f 1' .I- 4 .1 (nP) .1, 4 T "l- Rfa BOTTOM ON LEVEL STABLE BASE 4Pa MATERIAL PLAN VIEW /i�/���y/y a�//�.y//�� 6" MIN. 3/4" To CROSS-SECTION VIEW PLAN VIEW CROSS-SECTION 1 1/2" STONE DESIGN CRITERIA: DESIGN FLOW: DATUM: 4 BEDROOMS AT110G.P.B./D 440 G.P,D. VERTICAL DATUM: N. G. V. D. BENCH MARK SET: TOP OF BOUND AT NORTHEAST CORNER OF LOT ELEVATION 11.54 NGVD I REQUIRED SEPTIC BENCHMARK 440 X 200% - 880 GAL. TDP OF CONCRETE ! SEPTIC TANK PROVIDED: = 1500 GGAL. N BOUND ELEV 11,54 t 13,4 / 11.5 SIZE OF LEACHING FACILITY REQUIRED: x o�� 109.26DESIGN PERC. RATE: <2 MIN./ INCH Z1 EXISTING p, LONG TERM APPL. RATE 0.74 G.P.D/S. F. 13 SEPTIC COMPONENTS TO BE PUMP, CLEANED m• PROPOSED AND REMOVED FROM_ 1500 GALLON SITE IN ACCORDANCE 32'5' 440 GPD 0,74 GPD/SF - 596 S,F, / SEPTIC TANK WITH TITLE 5. PROFILE: NOT TO SCALE z/ PROPOSED s'xao' SIZE OF LEACHING FACILITY PROVIDED: 1 OPEN PORCH TOP FOUNDATION FIRST PIPE LENGTH SHED CONCRETE COVERS TO WITHIN TO BE SET LEVEL 440 GPD _ 0.74 SF/GPD 595 S.F. EL.=11.5 6" OF FINISHED GRADE. FOR MIN. 2' S- WATER FINISH GRADE GATE EL.=10.9-11.9 / W / / USE LEACHING FIELD :4 -PVC SCH 40 PROPOSED O n sox / BOTTOM = 14' x 43' = 602 S.F U/ 100' 1s.� \ \ -� 4 PVCN� 11 ?. SCH 40 a' PVC SCH 4 LEACHING FIELDH PROPOSED LO PROPOSED SECOND 6(12 S.F X 0,74 SF/GPD = 445 GPD 14' x 43' I I I / STORY ADDITION / 3LLI I=E 1=D 1=G LEACHING �1 ( .. o FIELD I -C I=E a �. 5 OUTLET IaF .rte.. DIST, BOX 5 SEPARATION SEPTIC TANK 10.7 X F EST. HIGH GROUNDWATERr. I I I I PATTD °o / / ( -I K EXISTING TO / LOCUS INFORMATION ... . I ENOL INVERT ELEVATIONS: I I I! I I ENCLOSED 30 - CURRENT OWNER: GILBERT &CYNTHIA ... of - o }-- DESROCHES TOP OF FOUNDATION 12.17 A �� I I I ! _ _ _ � �1 1111 X111 1 = 36.8' TITLE REFERENCE: DEED BOOK 11609, PAGE 35 4" INVERT AT BUILDING 10.32 B I I 1 I - - - \ J PLAN REFERENCE: PLAN BOOK 145, PAGE 67 4" INVERT AT SEPTIC TANK (IN) 10.15 C PROPOSED I I I I _ ( ( a 4" INVERT AT SEPTIC TANK (OUT) 9.90 D �! ADDITION \ ASSESSORS MAP: o � I I I � � PARCEL: 16 160 4" INVERT AT DIST. BOX (IN) 9.84 E 4" INVERT AT DIST. BOX (OUT) 9.67 F I I ll,o I ZONING DISTRICT: SETBACKS: FRONT 30' ( I N SIDE 25' 10' I REAR 20' INVERTS AT LEACHING FACILITY: oTPni � ( I MINIMUM LOT SIZE: 25,000 S.F. 4" INVERT AT BEGINNING EXISTING LOT AREA: 8,740± S.F. OF LEACHING FIELD 9.60 G BREAKOUT 10.1 x 10.3 �- -- ( � OVERLAY DISTRICT: NONE 4 INVERT AT END 99 X -•-♦-♦-o-• OF LEACHING FIELD 9.40 H BREAKOUT 9.9 <p 109.01' - N88'16'20"W NITROGEN SENSITIVE ZONE: NOTA ZONE 11 �F\ �O ELEVATION AT BOTTOM y��d�oy FEMA FTRIC OF LEACHING FIELD 8.90 J LIMITS OFJ 9 ZONE DISTRICT: PANEL � 250015/0006 D ADJUSTED EXCAVATION. F� 3.90 K SEE NOTES 5 & 6 F` o EXIST. LOT COVERAGE: 1,087± S.F. (12.4) GROUNDWATER PROP. LOT COVERAGE: 1,637± S.F. (18.7%) LIJ LOCUS PLAN: VARIANCES REQUESTED: NO SCALE q NONE O�GQ v 28 FLOOR PLANS: W LOCUS C� ST, SEE ATTACHED. w > NOTE, PLAN \/ V I E W ~ J C� LD NOTE. FLOOD ZONE INFORMATION DEPICTED HEREON IS BASE ON A FIELD SURVEY, Q >_ WN AND ON SITE TOPOGRAPHIC INFORMATION. SCALE: 1 = 10 FEET W HYDRANT � J 0 5 10 20 FT. PROPOSED REAR ADDITION TO BE SET ON SONO TUBES Z _ REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE FACILITY AND THE PROPOSED ADDITIONS. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A #4 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 45% BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 1007 MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 107-1007 MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 0%-207 MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 0%-5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION CONFIRM LOCATION & NUMBER OF INVERTS. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. MCGROUP" 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR #55 HOLLY LANE SOUTH YARMOUTH MASSACHUSETTS PREPARED FOR: GILBERT & CYNTHIA DESROCHES 109 FERRY STREET SOUTH HADLEY, MA 01075 (413) 536-5000 DATE: JUNE 6, 2007 COMP. /DESIGN: K. HEALY CHECK: M. DIBB DRAWN: P. HAGIST FIELD: D. GAZZOLO / J. MCCARTIN FILE NO. 9240-SEP.DWG DWG NO. 5810-01 I JOB NO.4-9240.00 1 OF 1 SHEET PRECAST SEPTIC TANK o - 0 g^ �: 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. T 14" .' / 2% IIIN. FINISH GRADE � 4" MIN. LOAM &SEED e`- NLET TEE ;S 5'-1" -30 1/2' LOAM & SEED DISTURBED ARE I 5-2" -2 4'-6" 5'-8- ' 3.1 MAXIMUM .e 15MIN 4'-0" MIN. 90'BEND ON 1 �: 15 1/2" :..:.: . , .. ., ... . . Z LIQUID DEPTH OUTIEt TEE (OLS CONTROL) PRECAST DIST. Ij d 2" MIN. OF 1/8- TO i \ 4 a a`ePa 1/2^ WASHED STONE :� 6• °o r'"Pa," e a o + o + (V .. �. BOK � 0 1to�o It'd +o e a .•pew o ac o a /' �,p�e,Pa�? }o�a o 3/4" TO 1-1/2" DOUBLE EL = 0.0 11 120 UNSUITABLE - GROUND 'NATER ,o` Qf 3" �-1 �` WASHED STONE (NO FNES) f 1' .I- 4 .1 (nP) .1, 4 T "l- Rfa BOTTOM ON LEVEL STABLE BASE 4Pa MATERIAL PLAN VIEW /i�/���y/y a�//�.y//�� 6" MIN. 3/4" To CROSS-SECTION VIEW PLAN VIEW CROSS-SECTION 1 1/2" STONE DESIGN CRITERIA: DESIGN FLOW: DATUM: 4 BEDROOMS AT110G.P.B./D 440 G.P,D. VERTICAL DATUM: N. G. V. D. BENCH MARK SET: TOP OF BOUND AT NORTHEAST CORNER OF LOT ELEVATION 11.54 NGVD I REQUIRED SEPTIC BENCHMARK 440 X 200% - 880 GAL. TDP OF CONCRETE ! SEPTIC TANK PROVIDED: = 1500 GGAL. N BOUND ELEV 11,54 t 13,4 / 11.5 SIZE OF LEACHING FACILITY REQUIRED: x o�� 109.26DESIGN PERC. RATE: <2 MIN./ INCH Z1 EXISTING p, LONG TERM APPL. RATE 0.74 G.P.D/S. F. 13 SEPTIC COMPONENTS TO BE PUMP, CLEANED m• PROPOSED AND REMOVED FROM_ 1500 GALLON SITE IN ACCORDANCE 32'5' 440 GPD 0,74 GPD/SF - 596 S,F, / SEPTIC TANK WITH TITLE 5. PROFILE: NOT TO SCALE z/ PROPOSED s'xao' SIZE OF LEACHING FACILITY PROVIDED: 1 OPEN PORCH TOP FOUNDATION FIRST PIPE LENGTH SHED CONCRETE COVERS TO WITHIN TO BE SET LEVEL 440 GPD _ 0.74 SF/GPD 595 S.F. EL.=11.5 6" OF FINISHED GRADE. FOR MIN. 2' S- WATER FINISH GRADE GATE EL.=10.9-11.9 / W / / USE LEACHING FIELD :4 -PVC SCH 40 PROPOSED O n sox / BOTTOM = 14' x 43' = 602 S.F U/ 100' 1s.� \ \ -� 4 PVCN� 11 ?. SCH 40 a' PVC SCH 4 LEACHING FIELDH PROPOSED LO PROPOSED SECOND 6(12 S.F X 0,74 SF/GPD = 445 GPD 14' x 43' I I I / STORY ADDITION / 3LLI I=E 1=D 1=G LEACHING �1 ( .. o FIELD I -C I=E a �. 5 OUTLET IaF .rte.. DIST, BOX 5 SEPARATION SEPTIC TANK 10.7 X F EST. HIGH GROUNDWATERr. I I I I PATTD °o / / ( -I K EXISTING TO / LOCUS INFORMATION ... . I ENOL INVERT ELEVATIONS: I I I! I I ENCLOSED 30 - CURRENT OWNER: GILBERT &CYNTHIA ... of - o }-- DESROCHES TOP OF FOUNDATION 12.17 A �� I I I ! _ _ _ � �1 1111 X111 1 = 36.8' TITLE REFERENCE: DEED BOOK 11609, PAGE 35 4" INVERT AT BUILDING 10.32 B I I 1 I - - - \ J PLAN REFERENCE: PLAN BOOK 145, PAGE 67 4" INVERT AT SEPTIC TANK (IN) 10.15 C PROPOSED I I I I _ ( ( a 4" INVERT AT SEPTIC TANK (OUT) 9.90 D �! ADDITION \ ASSESSORS MAP: o � I I I � � PARCEL: 16 160 4" INVERT AT DIST. BOX (IN) 9.84 E 4" INVERT AT DIST. BOX (OUT) 9.67 F I I ll,o I ZONING DISTRICT: SETBACKS: FRONT 30' ( I N SIDE 25' 10' I REAR 20' INVERTS AT LEACHING FACILITY: oTPni � ( I MINIMUM LOT SIZE: 25,000 S.F. 4" INVERT AT BEGINNING EXISTING LOT AREA: 8,740± S.F. OF LEACHING FIELD 9.60 G BREAKOUT 10.1 x 10.3 �- -- ( � OVERLAY DISTRICT: NONE 4 INVERT AT END 99 X -•-♦-♦-o-• OF LEACHING FIELD 9.40 H BREAKOUT 9.9 <p 109.01' - N88'16'20"W NITROGEN SENSITIVE ZONE: NOTA ZONE 11 �F\ �O ELEVATION AT BOTTOM y��d�oy FEMA FTRIC OF LEACHING FIELD 8.90 J LIMITS OFJ 9 ZONE DISTRICT: PANEL � 250015/0006 D ADJUSTED EXCAVATION. F� 3.90 K SEE NOTES 5 & 6 F` o EXIST. LOT COVERAGE: 1,087± S.F. (12.4) GROUNDWATER PROP. LOT COVERAGE: 1,637± S.F. (18.7%) LIJ LOCUS PLAN: VARIANCES REQUESTED: NO SCALE q NONE O�GQ v 28 FLOOR PLANS: W LOCUS C� ST, SEE ATTACHED. w > NOTE, PLAN \/ V I E W ~ J C� LD NOTE. FLOOD ZONE INFORMATION DEPICTED HEREON IS BASE ON A FIELD SURVEY, Q >_ WN AND ON SITE TOPOGRAPHIC INFORMATION. SCALE: 1 = 10 FEET W HYDRANT � J 0 5 10 20 FT. PROPOSED REAR ADDITION TO BE SET ON SONO TUBES Z _ REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE FACILITY AND THE PROPOSED ADDITIONS. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A #4 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 45% BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 1007 MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 107-1007 MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 0%-207 MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 0%-5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION CONFIRM LOCATION & NUMBER OF INVERTS. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. MCGROUP" 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR #55 HOLLY LANE SOUTH YARMOUTH MASSACHUSETTS PREPARED FOR: GILBERT & CYNTHIA DESROCHES 109 FERRY STREET SOUTH HADLEY, MA 01075 (413) 536-5000 DATE: JUNE 6, 2007 COMP. /DESIGN: K. HEALY CHECK: M. DIBB DRAWN: P. HAGIST FIELD: D. GAZZOLO / J. MCCARTIN FILE NO. 9240-SEP.DWG DWG NO. 5810-01 I JOB NO.4-9240.00 1 OF 1 SHEET