Loading...
HomeMy WebLinkAboutEngineered Plan - 2016101.72 ACCESS COVERS MUST BE WITHIN 6" OF FINISH GRADE \FIRST 2' TO BE LEVEL 9" MINIMUM. 3' MAXIMUM COVER MIN 2" OF PEASTONE OR FILTER FABRIC 3/4" - 1 //2' DIA. 98 75 98 3 2 o DOUBLE WASHED STONE OAS 99.0 BAFFLE V65-jCRIEUSHED OUTLET 2-500 GAL LEACHING CHAMBERS D -BOX W/4' STONE AROUND. 12.8'w x 25'1 x 2'd 1500 GALH-20 SEPTIC TANK STONE OR COMPACTED BASE PROFILE : NOT TO SCALE / / I I I 6 so "E \ \ I 66• S7 \ \ I \ \ 1 \ \ I \ I l \ \ I 14 "OAK 1 \ \ I ztl, o 1 \ \ I s 1 \ \ I CESSPOOL 1 \ \ I \ \\ \ I�OIOl.6 14 OAK 2-500 GALLON 14 ' OAK 1 \ -'T--101.5 LEACHING CHAMBERS \ Q \SHED h 31, W/4STONE AROUND l V /500 GALLON 1 tri o BEDROOM SEPTIC TANK 1 1 V) CESS'POOL 14"OAK TF.s :...... \ m 4i I \ \ 101.1 I \ \ 1 BATHD -Box 1 \ \ i�P/O/.2 1 1 \ \ 14'OAK I \ 1 1 LAUN 101.4 1 \ \ 1 PORCH 24'OAK \ \ \ 1 L/V/NG \ \ \ KI TCyEN ROOM \ \ \ \ \ \ 12 -OAK 6'--- \ 12"OAK 14"OAK \ \ \ \ \ \ PA 7-10 BEORO04f BEDRO04f \ W \ \ \ \ \ BM. CORNQR STEP 1 1 \ W I I EL -/0/.791 METER PIT I I 100.5 I I O \ \GR4 PEI OR/vE \ \ J, L 0 T I \\\ \ `\ UP /6.457'-' S.F. \ I \ I /02.96' N 83°52'47"W LOCUS MAP i 10/.5 jj&1-4 /00.9 j� t � I 3 O y jn J 4 101.0 INVERT EL E VA T I ONS : INVERT AT BUILDING: 99.4 INVERT IN SEPTIC TANK: 99.0 INVERT OUT SEPTIC TANK: 98.75 INVERT IN DIST. BOX: 98.47 INVERT OUT DIST. BOX: 98.3 INVERT IN LEACH CHAMBER: 98.2 BOTTOM OF LEACH CHAMBER: 96.2 ADJUSTED GROUND WATER : N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE #l: 90.2 10 CB CONCRETE BOUND -W WATER L I NE O HYDRANT G GAS LINE OHW- OVER HEAD WIRES # LIGHT POST �- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEVI SION LINE -i- 40.4 SPOT ELEVATION ..--..--40 ....... EXISTING CONTOUR 40 PROPOSED CONTOUR DESIGN CRI TER IA: DESIGN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EQUALS 330 G.P.O. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200% - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W14' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. SOIL TEST PIT DA T4 I ND I CA TES �_ l NO I CA TES PERCOLATION _ OBSERVED TES T GROUNDWA TER 40' 136-1- NO WATER 90.2 DATE: JANUARY 7. 2016 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH Yarmouth Health Department PP ' VED F--rl;M- e Date GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE S/ TE PLAN. 3. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEAL TH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE". 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. 9. INVERTS AT THE DWELLING ARE TO BE RELOCATED TO THE LOCATION AND ELEVATION SHOWN. 1� TERRANN Y sF WARNER N No. 38721 a� SEPT / C SYSTEM LIES l GN /S-3 NORTH MAIN STREET. MAP 80. PARCEL SOUTH YARMOUTH. MA. PREPARED FOR: i NEz )=A / / L A CE 2 / 9 HAYNES ROAD. AVON. CT 0(500/ SCAL E: l ffi 20 FEBRUARY 2. 2016 STEPHEN A. HAAS _ ENGINEERING, INC / � P.O. Box 16 /�,/ -� South Denn i s, MA 02660 ( SOB) 362-8132 /13 4, JOB NO: 15-072 I TP # l 0" HORIZON TEXTURE COLOR I0l.5 A LOAMY 10 YR SAND 3/2 8" ------------- - 100.8 B LOAMY IOYR SAND 5/6 26' -------------- 99.3 C / MED I UM 10 YR SAND 7/4 40' 136-1- NO WATER 90.2 DATE: JANUARY 7. 2016 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH Yarmouth Health Department PP ' VED F--rl;M- e Date GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE S/ TE PLAN. 3. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEAL TH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE". 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. 9. INVERTS AT THE DWELLING ARE TO BE RELOCATED TO THE LOCATION AND ELEVATION SHOWN. 1� TERRANN Y sF WARNER N No. 38721 a� SEPT / C SYSTEM LIES l GN /S-3 NORTH MAIN STREET. MAP 80. PARCEL SOUTH YARMOUTH. MA. PREPARED FOR: i NEz )=A / / L A CE 2 / 9 HAYNES ROAD. AVON. CT 0(500/ SCAL E: l ffi 20 FEBRUARY 2. 2016 STEPHEN A. HAAS _ ENGINEERING, INC / � P.O. Box 16 /�,/ -� South Denn i s, MA 02660 ( SOB) 362-8132 /13 4, JOB NO: 15-072 I