Loading...
HomeMy WebLinkAbout33.234 - Site Plan and Sewage Disposal System (2)7 A - 1 c�/ion I/8' o I/�' ELEVT�� ,00��y� �"o, �` �o.o dos ZX was ad -S YS TEM D S Z Gamer avi/ �ccDclAi// sfone Design Flow: 3/4'+a Iv 9 3 bedrooms Cagy � gal/da - 3� a 1 washd - 2 Sep 1 1 c Tank : 3� o l x 200% g a 9 — I '_.� — zx f nee. Use 1500 Gal . Tank lis G.8 --- — — .... Leaching Fac i I i t../<r-s/ r 1.-10' Bottom : Gori ELEV /7./I /� -itgn� o%T.�/�kf��s ✓% I�� f%x85 jT Sides 1El EV i0le5- ELEV. TOTAL 7.j Ad • . G.W. Gal uee 6 crushed Tank an 12 J Note: Garbage disposal is, not permitted with this design, 6o't under Septic Tank and - - D -Box 1500 Ga I. Olaf. 1000 Gallon Box Leaching Fao I l I ty L OCA TI 0N MAP Septic Tank Pump Chamber � f �. Mono 1 th IC Monolithic Assessors Map 33 SYSTEM PROFILE /� �--- --,� Parcel 2,34 r - 7-fs</��z/r�/��/� C� 6����-_� /.S Area 7, 500 SF No to scale 'i5' AUGER HOLE TEST HOLE PUMP _ 11 Submersible Pump-./f/�'ir 1. fi9/l/-Lw/✓inn�iG �,.. I_ _ — I : 6.� ,osor �/8 y -- -- ---- Coawi! Saud 2) 2' Check Valve - Cost Iron or PVC�� iiG/G — — — — — — — JrA /dyk'sef in horizontdl pass#Ion -Sf%`�9//i7/7 3) Alarm Panel%JiP /(f)M ►!/A K 6 241 Pump Chombar - 1000 Ga!Ion Tonk vl+h!/ylY �/concrete manhole.,/�4D�w/ ft�jiC o� (%�/O� Qre 51 Alarm Is fo ba an a separate olrout } ���/ �/f. ��/ Lv .fjplGf� /j Z70�� 1•- tt'' �� From .the pump.. !!'' / �/ ( 757 (9 61 Piping la to be 2•dlam. PVC far faros main — — Tom= _ G�/� �0/ice (o.Of%�(�}S-Z.J�?!C2/�_ and 4'dlam. PVC for gravity pipe. /v! .3.✓ sr 71 PumpSequanoe: InSpectiOnPOrtD t^jJ_ / fj3LS%/1�4`L 2$— a1 Pump aff E1 . 3.6 0!!/11�.T•�/.% �ODO�a�fU.bC�.a.7bY/-i/O/ - b) Pump on El -l9,0- a) Alarm on El.. �/f o�FlJfti.T"D� 7./ �K Qj4H /1- nw./ o��e 0 o �V A � 608 U{ 7t/�O1 �av1c TnH l✓f �i f�eir o ilOrlJ: %�3�o%�s {� �C1J�Cxatl�utoLfcr S,�c Z//Gz j p _ �tYtQ SCtri� Gweiaye C IV"/tZ S1 - fes/-9Lrtrc �! l✓i�hv�f .S%�= /8��f� /Zo•' Date :Z; 9 D - DATE: 0/04 2tooP/ 'PERFORMED BY: 2. v)uv WITNESS: B.MurpA�{ NOTES '` DESIGN RATE: <2 min ./in, I.) EXISTING CESSPOOLS ARE TO BE PUMPED AND f ERCOLAT I ON TEST 0 1 BACKFILLED WITH CLEAN FILL OR REMOVED. Y•2.) UNSUITABLE SOILS ARE TO BE REMOVED FOR �4Cra!lOri5 6f Wv�c of 22'�ayew) AROUND LEACHING AREA AND REPLACED P < q de fin trt ISrn;n " WITH APPROVED FILL MATERIAL. RaAeo? m/n / * � 3.) DESIGN ENGINEER TO CERTIFY SOILS REMOVAL BEFORE SYSTEM INSTALLATION. GF?oufoVdAf ER AD J, (Pafe;9/d �,uS�.BI =� 4.) DESIGN ENGINEER TO CERTIFY SYSTEM INSTALLATION Gr'ouv%dwaiet- Fi, PRIOR TO BACKFILLING. � 3 3 to, d2rclfAe 5.) DISTRIBUTION BOX IS TO BE WATER TESTED AT l� MJW� riOneCfa4-�%2} Fw. �SGn/ovi THE TIME OF THE BOARD OF HEALTH INSPECTION.' _ O FG4-,$ �B. 6.) ALL AREAS DISTURBED BY CONSTRUCTION ARE GROLNDIr{�ATER AOJ (�a4,:+d/o4_) TO BE GRADED/ LOAM COVERED AND SEEDED. 6o3 — - 7--_, 7)Corner re+iiforcemenf isto ai/eYlap Groundwo+er Found Znfer/or watt" surface i, +1 6. sealed I ndex Wel I W4b 40 mi/ Polyvinyl barrio. Zone / G/ ( Rrn 9 E sneer 1 / /_ L �G/ot 87 �_� ,oev y� 1 e 1 F f o 6c Fie�►t t7lJf _ f'O . $�.1kC Wa // Z F hA' S Cori creie< COAICKETE 4v_17 gineer to:nspa-#reinfo.'t'Pw Add . G , W . dep f h ' FIFrAINING n s Y Re l„ lI70 Clear r Q Wall lI �}cL ��.NEERI%C.IF C. ` 941 MAIN STREET, SO. HARWICH, MA 02661 432-2878 ,\� '-40>r,r P°I' "'y/ S/ TE PLAN SEVIAGE DISPOSAL SYSTEM IN YARMOUTH y4 FOR " fi ^l Yy 8„ ROBERT L ROYS TER t: < 20 HOPE ROAD V. 20 SOUTH YARMOUTH MA PROJECT: 04-122 SCALE: 1 '-20 , �, ,Add Test ole v/ (. i!evJsed� I 04 Move SAS e'fbward f rr / � � the dwe/lin Ind7`u71 ConGrC7Q /'e w5st', �� jj:a`,, •1 ,G.'dd Pmj �✓ n�t� �a 11 as sftous t7