HomeMy WebLinkAboutReview Checklist � TOWN OF YARMOUTH
�� s�(' SEWAGE PLAN REVIEW CHECKLIST
• Location: AM `f/ LOT��`� Date of Subdivision Approval
Street � Zone of Contribution: In Out
Vil �
lagc Commcrcial Rcsilcntial
Owner: �/ea'f�� �� Installer
? -
Builder: Engineer ���� ��P��!
,
7 -'
N/A YE S NO
1. Required number of copies received. �_.---�`'
2. Date of soils exam and percolation test not older than 2 years. /
3. 4 feet of naturallv occurrin�pervious material. above water table(new constructionl ✓J
4. Foundation 2 feet above high point of frontin� road for new construction. �_l
5. Water availabilitv letter from Water Deuartment for new construction. :�
6. Benchmark indicated and shown-NGVD if near wetlands. >�`'
7. Building se�ver does not.exit center of house. � '
8. Septic tank a minimum of 10 feet from house and deck. �.--�''
9. Leachin� a minimum of 20 feet from house and 10 feet from deck. �----�'J
10. Leachin� a minimum of 100 feet from wetlands. �_�-
11. Leachin a minimum of 150 feet from drinkin well /2 f et from uri ation well .
12. Svstem meets all other setback requirements. % �� t.�:iG��°��.��;' ; �i������u� �.--�'
13. Uses adjustment for maximum high groundwater. � ,,---�' '
14. Leachine 4 -5 feet above adjusted water table or bottom of test pit. �--='
15. Svstem not in top or subsoil or 5 foot removal. � /
16. Proposed contours are suitable. : �'
17. Svstem meets slope re�uirements - min. 1/8". 1/4" Qreferred. ,--�
, 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. _/
19. Specified tee sizes are�roper. gas bai�le on outlet tee. �/
20. Sewage flow under 10.000 g d�for�arcel.
.21 No _a� rbage dis�osal �_---'_ _ _
22. Svstem adequatelv sized for its intended use. ��---
23. Minimum 6" stone or mechanicall�compacted below the tank and d-box. �_
?4. Manhole covers within 6" of grade - septic tank and pump chamber. , �--�'
25. Electrical permit for.�ump chamber. ��
?6. Pump svstem - 2" line, weep hole. check valve, sanitary in d-box. alarm on separate circuit.----'"
27. Se tic tank and um chamber to be Facto wate roofed. _.-
28. Vent provided i leaching below 3 feet or under driveway or garking, rs� �---'
29. En�ineer to inspect and certifv : a. clav removal ""f
b. wall construction schedule --� �
c. commercial system
30. En�ineer and Land Survevor stamp and signature. ,��--
31. H20 loadirn� when svstem subject to vehicular traffic. ,
32. Title V application and fee si ng ed bv a licensed installer. ,� ._-
33. Foundation tiooting 2 feet above adjusted water table. `----
34. Lot subdivided prior to Julv 31. 1986 - Nitrate Loadin�. �--
35. Subdivided prior co April 7. 1989 - Phosphorus Zone 300'. -
Plan reviewed bv: r�rr"����r� �
, � ,.
�