Loading...
HomeMy WebLinkAboutReview Checklist � TOWN OF YARMOUTH �� s�(' SEWAGE PLAN REVIEW CHECKLIST • Location: AM `f/ LOT��`� Date of Subdivision Approval Street � Zone of Contribution: In Out Vil � lagc Commcrcial Rcsilcntial Owner: �/ea'f�� �� Installer ? - Builder: Engineer ���� ��P��! , 7 -' N/A YE S NO 1. Required number of copies received. �_.---�`' 2. Date of soils exam and percolation test not older than 2 years. / 3. 4 feet of naturallv occurrin�pervious material. above water table(new constructionl ✓J 4. Foundation 2 feet above high point of frontin� road for new construction. �_l 5. Water availabilitv letter from Water Deuartment for new construction. :� 6. Benchmark indicated and shown-NGVD if near wetlands. >�`' 7. Building se�ver does not.exit center of house. � ' 8. Septic tank a minimum of 10 feet from house and deck. �.--�'' 9. Leachin� a minimum of 20 feet from house and 10 feet from deck. �----�'J 10. Leachin� a minimum of 100 feet from wetlands. �_�- 11. Leachin a minimum of 150 feet from drinkin well /2 f et from uri ation well . 12. Svstem meets all other setback requirements. % �� t.�:iG��°��.��;' ; �i������u� �.--�' 13. Uses adjustment for maximum high groundwater. � ,,---�' ' 14. Leachine 4 -5 feet above adjusted water table or bottom of test pit. �--=' 15. Svstem not in top or subsoil or 5 foot removal. � / 16. Proposed contours are suitable. : �' 17. Svstem meets slope re�uirements - min. 1/8". 1/4" Qreferred. ,--� , 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. _/ 19. Specified tee sizes are�roper. gas bai�le on outlet tee. �/ 20. Sewage flow under 10.000 g d�for�arcel. .21 No _a� rbage dis�osal �_---'_ _ _ 22. Svstem adequatelv sized for its intended use. ��--- 23. Minimum 6" stone or mechanicall�compacted below the tank and d-box. �_ ?4. Manhole covers within 6" of grade - septic tank and pump chamber. , �--�' 25. Electrical permit for.�ump chamber. �� ?6. Pump svstem - 2" line, weep hole. check valve, sanitary in d-box. alarm on separate circuit.----'" 27. Se tic tank and um chamber to be Facto wate roofed. _.- 28. Vent provided i leaching below 3 feet or under driveway or garking, rs� �---' 29. En�ineer to inspect and certifv : a. clav removal ""f b. wall construction schedule --� � c. commercial system 30. En�ineer and Land Survevor stamp and signature. ,��-- 31. H20 loadirn� when svstem subject to vehicular traffic. , 32. Title V application and fee si ng ed bv a licensed installer. ,� ._- 33. Foundation tiooting 2 feet above adjusted water table. `---- 34. Lot subdivided prior to Julv 31. 1986 - Nitrate Loadin�. �-- 35. Subdivided prior co April 7. 1989 - Phosphorus Zone 300'. - Plan reviewed bv: r�rr"����r� � , � ,. �