HomeMy WebLinkAbout46.47 - Site PlanS mGO GO HORSE n POND ROAD O m 0 NKEY: 4 EXISTING CONTOUR:- — — - PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 55. TEST HOLE: UTILITY POLE: -C- FENCE LINE: - HYDRANT: RETAINING WALL: o BU ISLAN0 RO LOCATION MAP LOT 10 (12,187 SF) ASSESSORS MAP: 46 PARCEL: 47 LAND COURT CASE # 28750A FLOOD ZONE: C BENCHMARKAT RIGHT CORNER OF CONCRETE STEP ELEVATION = 100.8; 102--�- - SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY -2C-2- DAYS =_M_0 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x TEFF. DEPTH) WITH 4' OF STONE ALL AROUND (25' x 12.8' x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) =_112 GAUDAY BOTTOM AREA: 25' x 12.8' = 320 SF (0.74) = 237 GAUDAY CAPACITY= 349 GAUDAY -.-------102 ------ --1101 SEPTIC SYSTEM SECTION ELEV. (EXISTING) ° BED BATHI KITCHEN ROOM Lt7m BED BED LIVING ROOM ROOM ROOM 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP. 14" DOWN GARAGE I EXISTING FLOOR PLAN I \"- 149.16' / i '� p0 ------ SCP JCP I CP i 101 � �." ST )/ M9-19 � o m DECK inveA = 99.3 z -TING 3BEDRODG o DWELLIN1p1.2.3 No $ T top Ind? MAX HARRIS C I _ter N 66 57 00 / TH-1 I min / / / /Qm GARAGE /4a QO PAVED Q 'pRIVE' / \ / 3 �o co ' / ti i y 0 ` m / R / /J / 65.9T i S 84"23'40" W Edge o pavement HORSE PONS ROAD RIGHTHCORNAT EROF BOTTOM STEP ELEVATION = 100.93 T MAX. COVER IV MIN) D -BOX (6" OF STONE UNDER) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, RE WITNESS: AMY VON HONE, R.S. DATE: 7-16-09 PERCOLATION RATE: <2 MIN/IN PEASTONE 3/4" - 1 1/2" WASHED STONE /-INSPECTION PORT � ELEV.= 97.0 I IBJ 94.0 E? ELEV. 25'x 12.8'' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) (H-20) TH-1 995 O/A HORIZON ELEV. LOAMY SAND 10YR 3/2 C HORIZON MEDIUM SAND 2.5Y 7/6 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENT CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. SITE PLAN Dom/ i LOCATION: 23 HORSE POND RD., W. YARMOUTH, MA PREPARED FOR: ci% ? MAX HARRIS 0, 3u471 p "' jy' I DATF-7-29-09 SCALE: 1"=20' / N 66 57 00 / TH-1 I min / / / /Qm GARAGE /4a QO PAVED Q 'pRIVE' / \ / 3 �o co ' / ti i y 0 ` m / R / /J / 65.9T i S 84"23'40" W Edge o pavement HORSE PONS ROAD RIGHTHCORNAT EROF BOTTOM STEP ELEVATION = 100.93 T MAX. COVER IV MIN) D -BOX (6" OF STONE UNDER) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, RE WITNESS: AMY VON HONE, R.S. DATE: 7-16-09 PERCOLATION RATE: <2 MIN/IN PEASTONE 3/4" - 1 1/2" WASHED STONE /-INSPECTION PORT � ELEV.= 97.0 I IBJ 94.0 E? ELEV. 25'x 12.8'' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) (H-20) TH-1 995 O/A HORIZON ELEV. LOAMY SAND 10YR 3/2 C HORIZON MEDIUM SAND 2.5Y 7/6 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENT CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. SITE PLAN Dom/ i LOCATION: 23 HORSE POND RD., W. YARMOUTH, MA PREPARED FOR: ci% ? MAX HARRIS 0, 3u471 p "' jy' I DATF-7-29-09 SCALE: 1"=20' J BASS RIVER ENGINEERING THOMAS J. McLkl-AN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426