HomeMy WebLinkAboutReview Checklist .;R�µx . ���� // ,/ r
�4 [.� ..�{•���
Y f� � /� TOWN OF YARMOUTH = 7 � ;
��
SEWAGE PLAN REVIEW CHECKLIST /�' �� �y/�� / ' ,
Location: A.M.� Lot �- � Zone of Contribution: In X Out_ Acreage�^`�'���;
O ���� � Commercial: Residential:�_ ,
Street: �"
Villa.ge: Floor Plan: ✓ #Bedrooms: 7 '
Owner: V�' �/ -C jL��f Insta.11er: �
Address: Phone:
Phone: �(1 Z�`7- 7 � ,
Builder: �j,f�� Engineer: �-Ul! r �/
-�
Address: Phone: y"
Phone:
N/A YES NO
1.R uired#of c ies received
2.Date of soils e�m and ercola.tion test not older than 2 ears
3.4-5 ft of na.tura occurrin ervious ma.terial,above water table
4.Founda.tion 2 ft above hi oiut of road H.P.: Fnd: Var.:
5.Water line 10 ft from s tic com onents Var.:
6.Benchmark indica.ted and shown-NGVD if near wetlands r
7. S tic tank minimum 10 ft from foundation, deck Var.:
8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ;
9.Leachin minimum 100 ft from wetlands Var.:
10.Leachin minimum 150 ft from drinkin welU25 ft irri tion well Var.: ��
11.Tank/leaching minimum 10 ft from r erty line Var.:
12. S stem meets all other setback r irements Var.: '
13.Uses adjustment for ma�m_um high oundwater Var.:
14.Leachin set 45 ft above adj.water or bottom of test hole Var.:
15.S stem not in to or subsoil(A,B horizons)or 5'removal � w;
16.Pro sed contours aze suita.ble '
17.S stem meets slo e r irements-min. 1/8", '/4" eferred
18.S stem meets breakout r uirements PVC liner: Wall: `'
19.S ecified tee sizes aze r er, baffle on outlet tee '
20. Sew e is under 10,000 gpd for arcel •
21.No ba. e dis osal
22. S stem ad uatel sized for its intended use
23.Minimum 6"stone or com acted below tank and dbox '
24.Manhole covers within 6"of e, um chamber cover to grade . � '
25.Ins ion ort on lastic chambers/leach field `
26.Electrica.l ermit for um chamber/S ate meter for du lexes
27. stem-2"line,wee hole,check valve,tee in dbo� um size ✓ '
28.S tic tank/ um chamber to be factory waterproofed
29.Vent rovided if leachin below 3 fcet,under drivewa. / arkin
30.Buoyancy calculations for tank/ ump chamber
31.E ' eer to ins ect and c ' soils: wall: commercial: '
32.En ' eer/Re � ered Sanitarian and Land Surv or s/signature
33.H-201oadin is sub'ect to vehicular traffc, oundwater ✓
34.Title V A lication and ermit fee,installer si ture
35.Foundation footin min.2 feet above adjusted ound water for new house -�
36.Deed Restriction r ired max. #bedrooms: ma�c. flow: '
37.Check azea lots for oundwa.ter/Label oundwater in Assessor's Ma
�;
Plan reviewed by: ���, sro3ro�