HomeMy WebLinkAbout23 Iroquois Blvd - Septic System 4GENERAL NOTES: 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BEECH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. S. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. 7. EXISTING INVERT AT THE BUILDING TO BE RAISED TO THE ELEVATION SHOWN. 6. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 9. EXISTING CESSPOOL TO BE PUMPED DRY AND BACKFILLED. I0. ALL UNSUITABLE MATERIAL (A d B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 11. THE ENTIRE LOT FALLS WITHIN FLOOD ZONE B. ACCESS COVERS MUST BE WITHIN 9' MINIMUM. 6' OF FINISH GRADE 3' MAXIMUM COVER 103.33 FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE iJ 4- VIAM PIPE -7- 3/4' - 1 1/2' DIA. 102.37 6 T 101.9 101.7 d4 7- $. WASHED STONE 102.15 +� 101.87 101.68_ _0 01 3 OUTLET 5 STANDARD INFILTRATOR D -BOX CHAMBERS W/3.S't STONE AROUND 1500 GAL !0'• X 38'I X 7'd $EPTIC TANK 6' CRUSHED STONE BASE PROF/ L E: NOT TO SCALE SOIL REWYAL 100.6 r SEE NOTE 10. i LOT 18 13093 t S.F. INVERT ELEVATIONS: INVERT AT BUILDING: 102.37 INVERT IN SEPTIC TANK: 102.15 INVERT OUT SEPTIC TANK: 101.9 INVERT IN DIST. BOX: 101.87 INVERT OUT DIST: BOX: 101.7 INVERT IN LEACH CHAMBER: 101.68 BOTTOM LEACH CHAMBER: 101.1 ADJUSTED GROUND WATER+ 97.1 OBSERVED GROUND WATER: 95.4 BOTTOM OF TEST HOLE •l: 93.1 INDEX WELL M1W 29. ZONE A MAY 99 READING -8.3'. AD✓ -1.7' N DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT I10 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200% - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ! 5 MIN/INCH SOIL TEXTURAL CLASS - 1. EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED PROVIDED: 5 STANDARD INFILTRATOR CHAMBERS W/4'f STONE AROUND. A-447 S.F. 447 S.F. x 0.74 - 33/ GPD SOIL TEST PIT DA TA INDICATES INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP �l 0' HORIZON TEXTURE COLOR 100.1 A LOAMY IOYR SAND 3/2 ! 1 ' .... ....... ......... ..... .......... 99.2 8 LOAMY IOYR SAND 4/6 /B ................ .......... ............... 98.6 C l MED COARSE 7.5YR SAND 5/8 4?' �44' ........ 96.4 ...C2••.. . MEDIUM IoY.Q SAND 5/6 -