HomeMy WebLinkAboutEngineered Plan - Rev. 2016s /V1AIf`TOII/�T OAI/Cn 0=11 T/•f - SITT PLAN 1"= ,go .1 L,k'6.!F � - - BL'NCHffARI� Test hole location -1, Existing contour -12- Proposed contour 000 Septic tank EA7 RAL NOTE'S:• Pistribution box LOAM Cultec Recharger 180 3 - 10 Absorption trench (NA V0 88) (2 req "d) o C.B. Concrete bound -W- Xater service - U- Unerground utilities 13x8 f'xisting spot grade ./13.8 Proposed spot grade - - BL'NCHffARI� DEPTH SOIL SOIL ELEVA77ON (IN.) HORIZON TD(TURE (FT.) NO.1 0 DEPTH (IN.) TOP of C. B. FND Current Zoning • R-25 EA7 RAL NOTE'S:• EL= 12.51 LOAM 12.2-12.0 3 - 10 A (NA V0 88) ffin. Bldg: Setbacks • 1. System is designed in accordance with "Commonwealth of Afars, B1 pt. LOAMY SAND 11.4 - 9.4 34 - 124 C Of Environmental .Protection„ 310 CAfR 15.00; the State E'nvir7nmental Code, ' EXCAVATE FOR 5' AROUND ABSORPTION Front (Road) 30' Title 5.• Standard Requirements for the Siting Construction, Inspections SYSTEM AS REQUIRED TO REMOVE ALL SOIL Rear 20' Upgrade and Expansion of On -sate Sewage Treatment and Pisp sal Systems" Town Regulations ABOVE THE (C) MEDIUM SAND LAYER. BACK FILL WITH MATERIALS MEETING THE Sidelines 15' 9.. and the of TARAfOUFH No wells or water supplies aro known to exist within 100 feet of the SPECIFICATIONS OF 310 CMR 15.255 (3) proposed leaching system. All wells known to exist within 150 feet of AND (6). NOTIFY HEALTH DEPT. FOR Prop. Building Coverage the system are shown. INSPECTION OF EXCAVATION PRIOR TO BACK d 3. Prior to backfilling completed systems notify the Boar' of Health for FILL.+'NG. PROVIDE 24-HOUR (MIN) NOTICE 3, 918 SF (23.990) inspection. Frvvide e4 hours (min.) notice for inspection, FOR INSPECTION 4. Cont7actor shall be responsible far verifying location of all underground T�n BUILI)I1V0 HEIGHT Cr4LMUTIONS utilities prior to excavation. r, AVG. NATURAL GRADE ELEV. J2.0' 5. Any changes to this pian must be approved, by the Boar' of Health. m 4 MAX. ALLOWABLE RIDGE ELEV. 47.0' 6. Lot is served by Town water. _? X cr PROP. RIDGE ELEV. 45.7' 2: No garbage disposal allowed with this design. 1 �= •-� PROP. HEIGHT 33.7' o LOCATION ffAp Not to Scale ROUTE 28 F� �O S 5Q�\ GR LOCUS RL'FL'R�NCL'• Assessor's ffap 23 Pcl. 345 P.B. 120 Pg. 89 TYPICAL S'YS'77 ff PROFILE Mot to scale Afaintain a maximum of 36 cover over 11 V Q ZONE AE all system components All components (L " Tank &D.Box to be installed on a X level, stable base (min 6" stone base) shall conform to specifications contained (EL 11) in 310 0& 15.00. r 1 TOP of PROVIDE INSPECTION 20" Dia. comer 20" Dia a ( Foundation to itl�i 6 . covers PORT ON END UNITS 14.60 13 of ,Ndnasgrzde CULTEC RECHARGER 180 WITHIN 3" OF FINISHED fo , Alin. .� GRADE. f a 19 H 5 typ . Inv. El. ......... PGE .3 9.. Note: 11.17 9 R7in. outlets cover GPE1 ..'.'.'.'.'.'.'.rto bz, vel (exc/ud. 5�g....................... L 4" D a top soil) 141, Dra .......... �. Inv.�'l. / 6 Flow line ' S'cPYC D %,Schad 40 P.Y.C. LOT 43 ~`! 12.10 1500 Inv. A7.14" Effec. depth 16,J74 S. F. f 4' cast iwn BOTTOM EL. or sched.40 Callon Capacity Inv. El »23 = 10.0 1,3.8 ��,� (0.37 �) F d 1, P. V C. pipe septic Tank 11.60 (ffater tern 7vinf. cone.) Inv. A7 Inv. El. 11.40 5' MIN. ►\� _ !"'; 11.85 .. .. .. All tees 6 � art s or 2 - - - - - - - - - - - - �iat1 .. � or 40 P. p(W rows @ 8 units long (51.7) MAX. H2O 0 No garbage grinder cast -in-place conomte. EL. = 5.0 13 �o L nI 2 allowed witA this design. Iivv gas baffle on ordlei tee. 5 6o1rd) Re CULTEC RECHARGER *180 0 01' 100,03 TRENCH DETAIL EFFECTIVE NG AREA I�.ES16W IATA BACKFILLED LW THIAPPROVED FILL' Number of bedrooms: 6 660 GPD TL',ST HOLD' DATA DATE OF TEST HOLES. 10-9-2014 AVG. WATER EL. = 2.3' INSP. BY- ECO -TECH; A. VON HONE (HEALTH DEPT) USGS ADJ. = 2.7' EST. MAX. H2O EL. = 5.0 BOTTOM OF PERC AT 60" (C -LAYER) <2MIN-11N. IWATER 0 113" (EL. = 2.8) I No. 3 DEPTH SOIL SOIL ELEVA77ON (IN.) HORIZON TD(TURE (FT.) NO.1 0 DEPTH (IN.) SOIL HORIZON SOIL TDaZIRE ELEVATION (FT.) 0-3 0 LOAM 12.2-12.0 3 - 10 A LOAMY SAND 12.0 - 11.4 10 - 34 B LOAMY SAND 11.4 - 9.4 34 - 124 C 1 MEDIUM SAND 1 9.4 - 1.9 BOTTOM OF PERC AT 60" (C -LAYER) <2MIN-11N. IWATER 0 113" (EL. = 2.8) I No. 3 DEPTH SOIL SOIL ELEVA77ON (IN.) HORIZON TD(TURE (FT.) 0-3 0 LOAM 11.7-11.5 3 - 4 F LOAMY SAND 11.5 - 11.4 4 - 12 A LOAMY SAND 11.4 - 10.7 12 - 36 B LOAMY SAND 10.7-8.7 36 - 120 C MEDIUM SAND 8.7 - 1.7 BOTTOM OF PERC AT 62" (C -LAYER) <2MIN./IN. IWATER 0 120" (EL. = 1.77 1 WATER ® 120" (EL. = 1.7) CULTEC NO. 410 No.2 %\� ,;`SAIIVE:;:: \ 4 / ' r.`-' DEPTH (IN.) SOIL HOR1,T )N SOIL TD(TURE ELEVATION (FT.) 0 - 4 0 LOAM 11.7-11.4 4 - 12 A LOAMY SAND 11.4 - 10.7 12 - 36 B LOAMY SAND 10.7-8.7 36 - 120 C' MEDIUM SAND 8.7-1.7 WATER ® 120" (EL. = 1.7) WATER 0 120" (EL. = 1.7) Min. Final Grade EI = 12.7 Estimated dally effluent. Effective leaching area as proposed: CULTEC NO. 410 No. 4 %\� ,;`SAIIVE:;:: \ 4 / ' r.`-' DEPTH (IN.) SOIL HORIZON SOIL TEXTURE ELEVATION (FT.) 0 - 5 0 LOAM 11.7 - 11.3 5 - 12 A LOAMY SAND 11.3 - 10.7 12 - 36 B LOAMY SAND 10.7 - 8.7 36 - 120 C' MEDIUM SAND 8.7 - 1.7 WATER 0 120" (EL. = 1.7) Min. Final Grade EI = 12.7 Estimated dally effluent. Effective leaching area as proposed: CULTEC NO. 410 VE=•.: ' ' :'�'':' /\\i 9' MIN. \\ "'' = 4. c _'s I \ / 36 MAX. PER TITLE 5 %\� ,;`SAIIVE:;:: \ 4 / ' r.`-' 16 units = 103 LF FILTER FABRIC 103 LF x 8.9 SF/LF = 920 SF> APPROVED BY CULTEC Leaching Capacity as proposed: TITLE 5 APPROVED FILL (Effluent loading rate = 0.74 GPD/SF) 920 SF x 0.74 GPD/SF = 680 GPD TOTAL = 680 GPD SEE 310 CMR 15.255(3) FOR SPECIFICATIONS. Yarmouth Health Department NOTE: "RE'CHARGER 180" SYSTEM SHALL BE INSTALLED BY A APPS VED CONTRACTOR TRAINED BY CULTEC, INC. ON THE PROPER INSTALLATIONS ' L OF THE SYSTEM. 11Lgine Date PROPOS.E.0 0ffrEZLING & ON -,SITE' ,SL'IYAGE TRL'ATt�l�NT AND DISPOSAL ,SY,S/TL' 1� '� ��� Prepared for. James and .Deborah Caola �G STEPHANIE fpµ_ °F ' Ssq .,. `"� Location.• 156 Springer Lane - Yarmouth, �L114 �ZN k a o SEQt1IN o CINIL DAVID Gs No. 37213' A �, 1P a 4 Ryder & Wilcox, Inc., P. E. & P. L. S. LYTTLE ��ss/ sT>~ �.3 Giddialz Hill Rd. #346Zo�aAL P. O. Box 43.9 ' �qa FSs yoe- So. Orleans, .fA., 0266,2 Scale: s �� I Tel. 508 255-8312 Fawn by - SCIS Date - Feb. 24, 2016 Fax.508 �1 i % 240-2306 Rev. - 1Llar. 17 2016 Reserve Job No. 7755%