Loading...
Engineered Plan - Rev. 2015SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE 7' FILTER FABRIC OVER STONE 35.0 A/IAIIAIIIAI 7RI r rm/CD M/CD DD CrACT ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 34.0' (7.5 % SLOPE) _ ( 1 % SLOPE) FOUNDATION 18' SEPTIC TANK 9' — *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- 99— EGEND 99— EXISTING CONTOUR X 99-1 EXIST. SPOT ELEV. 99 NOTE.' 2" MIN. WALL 198.41 BLOCKS OR TH1 PRECAST H-10 RISERS (TYP.) TEST HOLE 2� SLOPE OF GROUND THICKNESS REQUIRED UTILITY POLE FIRE HYDRANT PRECAST RISERS 2'o 2= 0/d Townhouse Rd. 4"OSCH40 PVC Stam MORTAR ALL a ordina o B PIPES LEVEL 1ST 2' c COMPONENTS (NP') , ind'amm r � Suffolk ENDS o SIDES *32.5' 0 1 On 1500 GAL H-10 14" TEE Y'OJ°Oi°O�°^Y' _ °_o o ° ��E�m DD�L� o 0 0 0 0 0 0 O'O O Oa'ol o ° ° ° >00000000 0 0 0 0 0 0 0 0 ����—O �0�� 31.12 TEE SEPTIC TANK :. 0.87' `` 0 0 0 o 0 °°°°°°°° OOOOOO<�OOOO 000aoom==[q OO�OOOOOOOO oaoaaoaooaa °O°OO°OO°0° o 0 0 0 GAS BAFFLE;; oo°°oo°°o°o° o 0 0 0 0 0 0 ° ° ° ° ° ° N00000000 �_000�o�o„o_ 00000000 0000000000 oa�aooa000❑ 0�0 0000000 amar�000a000 ;00000000 00000000c, aooaa�aa�o� aoaao�a0000 ;0000 30.77' 30.60' o°o°0000; >°0°0°o°o °�°�°�°� +: 4' LIQ. LEVEL (ACME OR EQUAL),-., -" WATER TEST D'BOX FOR LEVELNESS EL. 28.5 °o°o°o°o°o°o°0°0°0°0°0°0°0°0°0°0°0�0°0°0°0°0° H-10 500 CAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. �,o,o„o_0_°_n_�_� ° o 0 0 ° o_�_°_ _n_o.o 0 , 3/4"-1-1/2' DOUBLE WASHED STONE 4' MIN. (2UNITS REQUIRED ) ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) LO (7.5 % SLOPE) _ ( 1 % SLOPE) FOUNDATION 18' SEPTIC TANK 9' — *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- 99— EGEND 99— EXISTING CONTOUR X 99-1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 00 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 7/29/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS �] ELEV. 1 0" 33.5' A LS 4„ 1OYR 5/2 B LS 21" 1 OYR 5/8 31.8' C PERC FS 2.5Y 7/3 138" I 122.0' NO GROUNDWATER ENCOUNTERED DCE #15-167 m 0 (—!—% SLOPE) — 12' — Scale:1 "= 20' 0 10 20 30 40 50 FEET LEACHING FACILITY 22.0' BOTTOM TH-1 NO GROUNDWATER FOUND wmw�— - DATE NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 87 PARCEL 6 SITE IS LOCATED WITHIN A ZONE II 2 BEDROOM DEED RESTRICTION REQUIRED SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS Com? 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) 440 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD \ USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND iV DANIEL A. OJALA, P.E., P.L.S. Date APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #4 TEMPLETON PLACE WEST YARMOUTH, MA PREPARED FOR DAVID PANKRATZ DATE: JULY 31, 2015 REV: AUGUST 20, 2015 (2 BEDROOM NOTE) off 508-362-4541 I fax 508-362-9880 downcape.com 00WO c41,0e en,gineerin.ff, inc. civil engineers Ion d surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 , MA e n X�t ain t 00 �o �L 0/d Townhouse Rd. Locus Stam a ordina o B c a ind'amm r � Suffolk o O 0 LOCUS MAP NOT TO SCALE ASSESSORS MAP 87 PARCEL 6 SITE IS LOCATED WITHIN A ZONE II 2 BEDROOM DEED RESTRICTION REQUIRED SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS Com? 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) 440 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD \ USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND iV DANIEL A. OJALA, P.E., P.L.S. Date APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #4 TEMPLETON PLACE WEST YARMOUTH, MA PREPARED FOR DAVID PANKRATZ DATE: JULY 31, 2015 REV: AUGUST 20, 2015 (2 BEDROOM NOTE) off 508-362-4541 I fax 508-362-9880 downcape.com 00WO c41,0e en,gineerin.ff, inc. civil engineers Ion d surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 , MA