Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
72 Keel Cape Drive Site Plan
ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE, m 6L0 61.2 M N/F BYRNE z Ei 2 61.3 ci BZ O. OPTION 2 IrO, " OPTION 1 Imo/ \ N 1200 , 61.33 I'll MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED: <^ �` HOLE PRIOR TO PLACING SAND No 1. NO RESERVE AREA IS SHOWN. 310 CMR 15.248., � � \` NOTES JOB No. Y -10-o IN BERM=60.99 ASSIGNED TO MEET TITLE 5 AND LOCAL REGULATIONS. Irwin.dwg -E- 1. LOCUS IS A.M. 101, PARCEL 62. -G- 2. ELEVATIONS SHOWN ARE ASSIGNED. 611 N/F KANE X0.0 3. LOCUS IS IN FLOOD ZONE C AND B ON FIRM DATED JULY 2, 1992. / 4. 5. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) MUNICIPAL WATER ' 6. IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. COMPONENTS TO BE AASHTO H-10, / 7. UNLESS NOTED. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". ERC RATE: <2'_ e CH 00 /Inch (Clayer)0 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW 0 / Nfl ^'8 FENCE (IF SHOWN, NOT ALL SHOWN) 9• D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. DEPTH / BENCH MARK -TOP, BACK, CENTER SEPTIC TANK= 60.22 � �-61-5,, OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. COVERS: BUILD UP COVERS TO 6" s ASSIGNED 10. BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING �\ oa i13 62 STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE 11. ON TOP. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, N CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 061 �` uIS INSPECTION SCHEDULE 12• IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING TO BE CLEAN � \� CALL R.J. CADLLAC OR HEALTH AGENT IL INSPECT 13. GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). PUMP AND FILL ANY LEACHPIT. REMOVE ANY CLOGGED SOIL B. EXISTING CESSPOOL/ � 60,07 61.16 . U' .� k N. Q1 <^ �` HOLE PRIOR TO PLACING SAND No AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT, cK, 14. ALL CONSTRUCTION � � \` O TH 1 TEST HOLE LOCATION, NUMBER IN BERM=60.99 ASSIGNED TO MEET TITLE 5 AND LOCAL REGULATIONS. \` -E- OVERHEAD ELECTRIC WIRES (IF SHOWN) [2(13'+ 33.5) X 2' DEEP)] -G- \ rya �" -C 460 GPD . 9.5 x$,7 NO GRADE CHANGES TEST HOLE DATE: Aril 21, 2010 p PERFORMED BY: Ron \ ��C��'�-C-C-G 00'9 N F ARE PROPOSED Cadillac, Soil Evaluator BY: Amy Von Hone, IRS, 61.9 \ ryp h C� / T H 1 CAMPBELL BEL ERC RATE: <2'_ e CH 00 /Inch (Clayer)0 EE�� E -E -E -E -E .. 76.. � `VM - � ��\' FENCE (IF SHOWN, NOT ALL SHOWN) SURVEY 1993: Carver coarse sand GEOLOGIC OLOGIC , ^i � �-61-5,, MAP(1986): Harwich outwash plain deposits 62 61.7 9iS a 0 61.1.- / 61.2 :'� b goFo ROU 7�2 -�- F 61,7 pRc =•::, �2 61.9 �647� 60.7 --6H4---X61,64 62.0 ^ PAVED DRIVE C, N61_ 74 s �-\61.57 `\ \ LOT 22 leoo<� 78 614 \`\ \h 21, 480±S. F h 6128 ' 61. 61,35. ` M \ , 1 �'`'� \ \ 61.2 0 \ ` i L 61,6h 61.17 y 61.14 �c.r� BDRM I BDRM I > I KITCH 2 BDRM BATH BDRM LVRM DINRM GARAGE BATH EXISTING FLOOR PLAN NOT TO SCALE 61,4 PAVED / PARKING 7 61.1 TH 2 015 :�3 2' • 61,9 61.17 , 61.4 l If I N""•42' / 60.92 r 60. 1 ;2ys 0. W 2P 1 60,81 r 61.6 ��60.71 60.; 60.72 x 60.5 60.7 61.4 60.69 60.5 .7t Top Found. Existing 1000 Gal. Septic Tank 6" Stone or Use Gas Baffle 3 DRY WELLS Existing invert 58.45 Proposed Top Conc =59.2 Top Peastone S=1/4"/ft S=1/81p/ft min. I vert 58.62 Invert 58-40 'roposed proposed 7'2' I I -16'-a Bottom DESIGN DATA CD BEDROOMS: LEGEND GARBAGE GRINDER: No REQUIRED CAPACITY: BENCH MARK --MAG- NAIL SET O TH 1 TEST HOLE LOCATION, NUMBER IN BERM=60.99 ASSIGNED -W- WATER LINE MARKINGS (ON RANGE UNE xm1 GARAGE HOUSE NO. -E- OVERHEAD ELECTRIC WIRES (IF SHOWN) [2(13'+ 33.5) X 2' DEEP)] -G- GAS LINE MARKINGS 460 GPD . 9.5 x$,7 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) EXISTING CONTOUR -$--- PROPOSED CONTOUR QI UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN - x - FENCE (IF SHOWN, NOT ALL SHOWN) OTREE (IF SHOWN, NOT ALL SHOWN) 60.72 x 60.5 60.7 61.4 60.69 60.5 .7t Top Found. Existing 1000 Gal. Septic Tank 6" Stone or Use Gas Baffle 3 DRY WELLS Existing invert 58.45 Proposed Top Conc =59.2 Top Peastone S=1/4"/ft S=1/81p/ft min. I vert 58.62 Invert 58-40 'roposed proposed 7'2' I I -16'-a Bottom DESIGN DATA CD BEDROOMS: 4 GARBAGE GRINDER: No REQUIRED CAPACITY: 440 GPD SEPTIC TANK: 1000 GAL. BOTTOM LEACHING AREA: 435.5 SF [(33.5' X 13')] SIDE LEACHING AREA: 186 SF [2(13'+ 33.5) X 2' DEEP)] DESIGN CAPACITY: 460 GPD [(435.5 SF + 186 SF) X -74 GPD/SF] N/F LEACHING OPTIONS MOORE I. USE 6 HI -CAP INFILTRATORS WITH 4' OF STONE ALL AROUND TO MAKE A 45.5' X 11' X 10 1/4" LEACH AREA=441 GPD. 2. IF LOAMY SAND ENCOUNTERED USE 3 DRY WELLS SET 4' APART FOR A 41.5' X 13' X 2' DEEP LEACH AREA=454 GPD USING <5 MIN./IN. ® 0.60 LOADING 24" TEST HOLE 1 SE NW DEPTH (inches) ELEV.(feet) 0 60.9 A layer 10yr 3/2 sandy loam 12" 8 layer 10yr 5/8 sandy loam 36" 57.9 C layer 10yr 6/6 54-01 medium sand 126" A IL,6 Zvi- Y LEACH AREA USE 3 DRY WELLS WITH 4' OF STONE ALL AROUND TO MAKE A 33.5' BY 13' WIDE BY 2' DEEP LEACH AREA. ro 54.9 N NW wall TH A� 8� TEST HOLE 2 DEPTH (inches) ELEV.(feet) 0 60.8 A layer 10yr 3/2 sandy loam 10" B layer 10yr 5/8 sandy loam 36" 57.8 3j 50.4 137" 60.99 SITE PLAN THIS PLAN IS A VALID COPY ONLY IF IT BEARS FOR AN ORIGINAL REQ STAMP AND SIGNATURE. D ER C_ V HEALTH AGENT APPROVAL C layer 2.5y 6/6 meduim sand 49.4 (X JOANNE IRWIN LOT 22S 72 KEEL CAPE DRIVE, SOUTH YARMOUTH, MA MAY 4, 2010 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN ILE CC P.O. BOX 258 WEST YARMOUTH, MA 02673 ,DATE ©2010 BY R.J. CADILLAC (508) 775-9700 PAGE 1 OF 1