Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2015ALARM AND CONTROL PANEL ACCESS FOR ROUTINE MAINTENANCE TO BE INSTALLED INSIDE ' MUST BE PROVIDED FOR ZABEL FILTER. BUILDING. ALARM TO BE ON INSTALLER MUST FOLLOW ALL SEPARATE CIRCUIT FROM PUMP MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION ACCESS COVERS TO,WLTHIN OF FIN. GRADE PROP. WATERTIGHT COVER TO GRADE TOP FOUND. EL. 20.75' MINIMUM .751 OF COVER 0 R PRECASTPROVIDE QUICK DISCONNECT FOR PUMP MINIMUM .75' OF COVER 0 RPR PRECAST H-10 PRECAST H-20 2" PRESSURE LINE RISERS (TYP.) RISERS (TYP.) SLOPE TO DRAIN BACK a.: 10.97' FLOAT SWITCH SETTINGS: 12.0'f* TEE - ALARM ON SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE NOTE: MIN. WALL THICKNESS 2" 4"0SCH40 PVC PROP. TEE I I I I PIPES LEVEL 1 ST 2' m goo ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM BLOCKS OR PRECAST RISERS MORTAR ALL COMPONENTS INVERT IN 3 (TYP.) SIDES 1883' 1 1.09' 6" MIN. SUMP o 0 0 o D����O 24" PUMP ON °00000 oo��000000 000000��0 0°0°0°0° 0 0 0 0 0 0 >°o°o°o°o ,° 0 0 0 °o�°,0�°,00000° 12" MIN. INT. DIM. c�i ;°0°0°0°0 ®0�������OO ®�0������a® •o0°0°Oo0 11.22. TEE 6., 00000000 ��DO���FP��0 0E��E2 M0MM�En 00000000 5" WORKING RANGE 18.3 18.13 °°°°°°°° °°°°°°°° 16.0 `WATERTEST D'BOX 'i�:r••' ZABEL FILTER 1500 MIN. GAL COMP. cJ" (A100) 6.5' 3'0' 12" PUMP OFF FOR LEVELNESS } r `H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL OUTLET TEE W/EXTENSION r 3/4"-1-1/2" DOUBLE WASHED STONE °000000 000 000 0000° WEEP HOLE °0°0° 00000 0°00 °0°0 CHECK VALVE 6" BAFFLE MYERS SRM 4 738 GAL COMP. SUBMERSIBLE 4/10 HP PUMP (__L% % SLOPE) SYSTEM (OR EQUAL) MIN. H_20 (ON BLOCK) FOUNDATION- 44' SEPTIC TANK/ PUMP CHAMBER *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM NOTE: INVERT OUT OF HOUSE EXITS BELOW THE FOUNDATION INVERT OUT IS APPROXIMATE 20 F_ 15 --- - Z 0 w 10 J 0 5 0 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP x15. \ \ \ \\\ BENCH MARK - T1 \ BOTTOM STEP. EL. \ \ \ \ \ \ o tO �9Cp_ ' \\ 26' ALL AROUND PRECAST STRUCTURES (4) UNITS REQUIRED OVERALL DIMENSIONS TO OUTSIDE OF.STONE: 39.0' X 10.83' j W o6 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) C2 LAYER (-j--% SLOPE) D' BOX 15' LEACHING FACILITY BUOYANCY CALLS: SYSTEM DESIGN: H-20 2500 GAL. ST/PC WEIGHS 28,000 LBS 3.51' x 11.0' x 6.0' X 62.4 = 14,456 LBS UP (OK) GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 2500 GAL.' SEPTIC TANK PUMP CHAMBER COMBO LEACHING: SIDES: 2.(39.0 + 10.83) 2 (.74) = 147 GPD BOTTOM 39.0 x 10.83 (.74) = 313 GPD TOTAL: 621 S.F. 460 GPD USE (4) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 3' STONE AT SIDES AND 2.5' AT ENDS 7'11A CqEp ,S' APPROVED DATE WATER PIT MA BOARD OF HEALTH CA rn po CF) 7.4' ADJUSTED GROUNDWATER GROUNDWATER ADJ. DATA: WELL: SDW-252 ZONE: A ADJUSTMENT: 0.9' (MARCH) I EXIST. D'BOX AND SAS SHOWN APPROXIMATELY ONLY (AS -BUILT UNCLEAR) LOCUS MAP NOT TO SCALE ASSESSORS MAP 131 PARCEL 14 VARIANCE REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): SEPTIC TANK TO BE GREATER THAN 36" BELOW GRADE BUT NOT MORE THAN 72" NOTES - 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 (TANK TO BE H-20) 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. ELECTRICAL PERMIT REQUIRED. LEGEND_ 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2,'/- SLOPE OF GROUND �Qo UTILITY POLE NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING 'I TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 4/24/15 PERC. RATE = < 2 MIN/INCH CLASS ISOILS 1 Q ELEV. 0 Tho h � Z Locus c� � y J 1OYR 3/2 oJ. Sond o �J B O ennis Pond 1OYR 4/6 17.0' C1 LOCUS MAP NOT TO SCALE ASSESSORS MAP 131 PARCEL 14 VARIANCE REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): SEPTIC TANK TO BE GREATER THAN 36" BELOW GRADE BUT NOT MORE THAN 72" NOTES - 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 (TANK TO BE H-20) 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. ELECTRICAL PERMIT REQUIRED. LEGEND_ 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2,'/- SLOPE OF GROUND �Qo UTILITY POLE NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING 'I TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 4/24/15 PERC. RATE = < 2 MIN/INCH CLASS ISOILS GROUNDWATER ENCOUNTERED AT 156" EL. 6.5' ,i!I weu �� � ill I III I II�Ii Q 'l IM III' Cp Illwl I N L... i lanai III kIp ! �I IIII ,.Id! I,:r. II i w Ill aui aI I'11�4 �.I!i 9 C A R L 0 S F 01"N'T S varmouu, 11u.-­ - APP"R )V . DATE: MAY 1, 2015 J� 7 �57 REV: MAY 29, 2015 (BUOYANCY CALCS, NOTES) Date r !I •\ in ,s � Scale: 1 = 20 0 20 30 40 50 FEET �_I(A OF 4f,18 SS9 N OF MgSS �yy C'y �yG �o DANIELA. G�< >9 �o DANIEL s� o OJALA -i off 508-362-4541 A.>> OJALA N U CIVIL "'fox 508-362-9880 No. 46502 I No. 40980 p�� c' R o downcape.com down canne �gineerin,f, inc. 104.00'Q SUR n1AL ANG civil engineers land surveyors 939 Main Street ( Rte 6A) LICE #95-355 DATE DANIEL A. OJALA, P.E., P. .S. YARMOUTHPORT MA 02675 95-355 UPGRADE 2015.DWG 1 Q ELEV. p" 19.5' A LS 1OYR 3/2 7" B LS 30" 1OYR 4/6 17.0' C1 PERC MS 90„ 1OYR 6/6 , 12.0 C2 SiL 120" 2.5Y 6/3 9.5' - FS 168" 2.5Y 6/4 5.5' GROUNDWATER ENCOUNTERED AT 156" EL. 6.5' ,i!I weu �� � ill I III I II�Ii Q 'l IM III' Cp Illwl I N L... i lanai III kIp ! �I IIII ,.Id! I,:r. II i w Ill aui aI I'11�4 �.I!i 9 C A R L 0 S F 01"N'T S varmouu, 11u.-­ - APP"R )V . DATE: MAY 1, 2015 J� 7 �57 REV: MAY 29, 2015 (BUOYANCY CALCS, NOTES) Date r !I •\ in ,s � Scale: 1 = 20 0 20 30 40 50 FEET �_I(A OF 4f,18 SS9 N OF MgSS �yy C'y �yG �o DANIELA. G�< >9 �o DANIEL s� o OJALA -i off 508-362-4541 A.>> OJALA N U CIVIL "'fox 508-362-9880 No. 46502 I No. 40980 p�� c' R o downcape.com down canne �gineerin,f, inc. 104.00'Q SUR n1AL ANG civil engineers land surveyors 939 Main Street ( Rte 6A) LICE #95-355 DATE DANIEL A. OJALA, P.E., P. .S. YARMOUTHPORT MA 02675 95-355 UPGRADE 2015.DWG