HomeMy WebLinkAbout32 Leeward Run - Proposed Septic Design, TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE ELEV. = 101.0_ 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB CONCRETE COVERS 4" SCHEDULE 40 PVC PIPE L,1,. PITCH 1/8' PER FT. LEGEND: 10'00 I 4" CAST IRON PIPE 94�30 (OR EQUAL) MINIMUM .. PITCH 1/4" PER FT. ELEV. = _111A_ ELEV. = -20,21_ TEE FLOW LINE ELEV. - 80.00_ LEVEL GAS Y ELEV. _ 6" SUMP ELEV. _$Z,¢j_ BAFFLE DISTRIBUTION (i0 BE PLACED ON FIRM BASE) BOX r TO BE WATER TESTED 1500 GAL LOIN IF MORE THAN ONE OUTLET SEPTIC ",'ti,�� (TO BE PLACED ON FIRM BASL) 3/4' TO 1 1/2" CLLAN DOUBLE WASHED FREE OF FINES 4 _:+! 1 SEWAGE D!S?OSAL SYSTEIJ PRonLE NOT TO SC..LE NO NO sj 1"O ,D, CT A,R� / 17, 60��'� f S� �. 0 al 89.66 Ole 00�/lgni / / /co i�/T �7y&,ia2)� j \ TE' 2 i 93.25 J 4 00 .28 1 � �SOIL� TEST 1 pit / 89.56 i(90) • so.o a o o�.sj � _ 96.98 �l / nd.20 o tgA)/ �• Aga 96. 1 ' 9 93 97.� 9 2 i 0 5.7 j' 9.60 \ %- w, EXISTING SPOT ELEVATION 00„0 EXISTING CONTOUR ----00---- FINAL SPOT ELEVATION ITO0.0 FINAL CONTOUR HORIZ SOIL TEST LOCATION MOTT, UTILITY POLE -'- TOWN WATER 6WW CATCH BASIN®j NO GAS LINE 30-58' CLEAN OUT LOAMY SAND 10YR6/6 CESSPOOL C.P. O 0 CLEAN SAND INSPECTION PORT LOAM AND SEED 2" LAYER OF \'WASHED STONE MAx REQUIRED 6 rn 0 10'H ELEV. PK9_67 E HIGH CAPACITY INFILTRATORS WITH STONE IN AN z I' X 48' X 10' TRENCH FORMATION � 7.47 SOIL ABSORPTION ZONE ZONE SYSTEM (SAS) INDEX ADJUST USGS PROBABLE WATER TABLE ELEV. = OBSERVED WATER TABLE ( / / ) ELEV. - V __ BOTTOM OF TEST HOLE ELEV. = 79.20 • 98.26 AW NAS BIVA"- • 98.64 �1 '11� FILE COPY SOIL TEST DATE OF SOIL TEST OCTOBER 25 2007_ SOIL TEST DONE BY SWE€SER ENGINEERING WITNESSED BY _&. YON HONf�- OBSERVATION HOLE 1 ELEV.= 89.6 DEPTH HORIZ TEXTURE COLOR MOTT, OTHER 0-30" Ap LOAMY SAND IOYR3/1 NO 30-58' B LOAMY SAND 10YR6/6 2. ALL COVERS TO SANITARY UNITS SHALL 13E BROUGHT TO REQUIRED SEPTIC TANK CAPACITY_�,°,0_ 58-120' C MEDIUM SAND 2.5Y7/4 GAL. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF SOIL CLASSIFICATION _150_0_ WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN DESIGN PERCOLATION RATE __h 5_3MIN./IN. 10 FT. OF DRIVES OR PARKING AREAS, H-20 LOADING SHALL BE EFFLUENT LOADING RATE DAY S.F. GAL.F/-/ USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. LEACHING AREA -03-4- 82843 SQ. f. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL (11X48)+(59%2%10/12) BE MORTARED IN PLACE. NO WATER ENCOUNTERED AT __120" ELEV. _ _ 79.6 OBSERVATION HOLE 2 ELEV.=89.2 PERCOLATION RATE _ < 2 MW./INCH AT ^80 +INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-34" FILL TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR NO 34-58' B LOAMY SAND 10YR6/6 2. ALL COVERS TO SANITARY UNITS SHALL 13E BROUGHT TO REQUIRED SEPTIC TANK CAPACITY_�,°,0_ 58-120" C MEDIUM SAND 2.SY7/4 GAL. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF SOIL CLASSIFICATION _150_0_ WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN DESIGN PERCOLATION RATE __h 5_3MIN./IN. 10 FT. OF DRIVES OR PARKING AREAS, H-20 LOADING SHALL BE EFFLUENT LOADING RATE DAY S.F. GAL.F/-/ USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. LEACHING AREA NO WATER ENCOUNTERED AT - 120' ELEV. _X9.2 DESIGN CALCULATIONS NOTES: NUMBER OF BEDROOMS 4 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. GARBAGE DISPOSAL UNIT _FTI_ TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR TOTAL ESTIMATED FLOW THE SUBSURFACE DISPOSAL OF SEWAGE. ( 110 GAL./8.4./DAY X 4 BR.) GAL./DAY 2. ALL COVERS TO SANITARY UNITS SHALL 13E BROUGHT TO REQUIRED SEPTIC TANK CAPACITY_�,°,0_ _.440_ GAL. WITHIN 6" OF FINISHED GRADE. ACTUAL SIZE OF SEPTIC TANK GAL. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF SOIL CLASSIFICATION _150_0_ WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN DESIGN PERCOLATION RATE __h 5_3MIN./IN. 10 FT. OF DRIVES OR PARKING AREAS, H-20 LOADING SHALL BE EFFLUENT LOADING RATE DAY S.F. GAL.F/-/ USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. LEACHING AREA -03-4- 82843 SQ. f. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL (11X48)+(59%2%10/12) BE MORTARED IN PLACE. LEACHING CAPACITY (AREA X RATE) GAL./DAY 5. NO DETERMINATION HAS BEEN MADE TO COMPLIANCE WITH SHEET 1 OF 1 ZONING DEEDED OR zONING REGULATIONS. OWNER /APPLICANT IS TO t326.S3 X 0.74 OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. RESERVE LEACHING CAPACITY �4.i4$ GAL. DAY / 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-a88-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER . - - - - IMMEDIATELY....... 8. PARCEL IS IN FLOOD ZONE __ _ 9. LOT IS SHOWN ON ASSESSORS MAP _ 91 AS PARCEL _ 146_, 10. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3j. 11. EXISTING BUILDING AND ALL UTILITIES (INCLUDING SEPTIC) ARETOBE REMOVED FROM SITE AND REPLACED WITH NEW. �W oi� T. A. DUMAS 140..619 I Yarmouth Health Department APPROVED APPROVED: BOARD OF HEALTH DATE AGENT C: I SB I PR0,71 6640-00 1 dwg 16640-sas. DWG U 2007 SWEETSER ENGINEERING L 6. <i tod Y SOUTH YARMOUTH, MA glti�o R eANK\ g Locus ) y` I P BASS R1 VER / PROPOSED SEPTIC DESIGN FOR DUBLIN CONSTRUCTION LQG.32 LEE, TiARD RUN, LOTS 23/24 SOUTH YARMOUTH, MASS. SUMER P ER FMGMERM 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 398_3922 SOUTH DENNIS, MASS. 02660 [!!NOV. 5, 2007 SCALE 1 > - 20' REV. NOV. 2O, 2007 JOB NO. 6640-00 LOCATION MAP REVISED i SHEET 1 OF 1 C: I SB I PR0,71 6640-00 1 dwg 16640-sas. DWG U 2007 SWEETSER ENGINEERING L 6. <i tod Y