Loading...
HomeMy WebLinkAbout22 Legend Drive - Site & Septic Plan6 ASSESSORS MAP: 90 1 \ ROUTR PARCEL E_7� LOCOS N CURRENT ZONING: R=20 (1966 SUBDIVIS70� BUILDING SETBACKS: SACA vft F: 30' S: 20' R' 20' FLOOD ZONE: C I 1 `Pd i I I LOCATION MAP \/ LOT 74 15,001 ± S.F. (0.34 ± AC.) UTILITY 52 sO 52 / / 50. 7 \51, icr Ito °� 52 51 �x A 2x — 50 Dg OS U� - 50. 65.0 / _ 5 M. 49 c 5`, 48 d 49.2� i.. •.. 49 C� .. •• �..• � E. LINE 06 ' sd , 47.0 KEY. EXISTING CONTOUR: — — — — PROPOSED CONTOUR: ...................••••••.•.•• EXISTING SPOT ELEVATION. 25.5 PROPOSED SPOT ELEVATION: 25 TEST HOLE: -$ UTILITY POLE: -0- FENCE LINE: — HYDRANT: -6 RETAINING WALL: TREE: DM # 28-208_(D31F14) BENCHMARK AT IRON PIPE ELEVP 472 MR TEST HOLE LOGS ENGINEER: DAVID BENNETT, R.S. WITNESS: AMY VON HONE, R.S. DATE: 7-8-97 PERCOLATION RATE: < 2 MIN/IN TH-1 TH-2 51A ALE HORIZON ELEV. A/E HORIZON SAND SAND 10YR 5/1 50.7 5" fOYR 5/1 B HORIZON B HORIZON LOAMY SAND' LOAMY SAND 10YR 6/6 49.4 24" fOYR 6/6 C HORIZON C HORIZON MEDIUM SAND MEDIUM SAND 10YR 7/6 10YR 7/6 NO GROUNDWATER ENCOUNTERED 494 ELEV. 486 474 394 SEPTIC SYSTEM DESIGN NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +/-) 2. MUNICAPAL WATER IS AVAILABLE. S. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 &• H-20 LOADING SPECIFICATIONS. 5. PIPE PITCH= 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USEOFA GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0. FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL/DAY/BEDROOM = 330 CAL/DAY SEPTIC TANK. 330 GAL/DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 CULTEC CHAMBERS (RECHARGER 330) WITH 4' OF STONE ALL AROUND (28' x 12' x 2' DEEP) SIDE AREA- (28 + 12.3)2 x 2 = 161 (.74) = 119 GAL/DAY BOTTOM AREA: 28' x 12.3' = 344 SF (74) = 255 CAL/DAY CAPACITY = 374 GAL/DAY SEPTIC SYSTEM SECTION 53.0 HTOP OF FOUNDATION 49 5 COVERS WITHIN 12" OF FINISHED GRADE ONE INSPECTION COVER OB WITHIN 6' OF GRADE) 4925 17 j i ELEV. 1500 GAL D -BOX 49.0 ELEV. SEPTIC TANK 49.17 (6" OF ELEV. 50.0 (6" OF STONE UNDER OR ELEV. STONE ELEV. MECHANICALLY COMPACTED) UNDER) TEE SIZES: GAS BAFFLE 48'92 INLET. • 6" UP 13" DOWN AT OUTLET TEE ELEV. 68' PROPOSED 3 BEDROOM 24, DUELLING 26, GARAGE 24• 4' 2- 6. 10' 1s PROPOSED DWELLING DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 PHONE d.• FAX : (508) 398-7710 OUTLET: 6" UP, 14" DOWN zanx�i% - -/ 9—�F,,�F APP �RIOVED BY: DATE: ST'YG`JQNV f t Z. �;3 Dn'?AREST JR THOMAS McLELLAN, P.E. 11 JOHN Z. DEMAREST JR., P.L.S. 2" PEASTONE 3/4" -1 V2 - WASHED STONE ELEV,- 49.4 I1 — F:I ZI 46.92 E4' ELEV. < 28' �m 3 CULTEC CHAMBERS (RECHARGER 330) WITH 4' OF STONE ALL AROUND (28'x 12.3'x2' DEEP) SITE AND SEWAGE PLAN LOCATION.• 22 LEGEND DRIVE SOUTH YARMOUTH, MA PREPARED FOR- REEF ORREEF REALTY SCALE: 1"= 20' DATE: 01112199 REFERENCE: LAND COURT PLAN #32679B SHEET 2