Loading...
HomeMy WebLinkAbout15 Lewis Bay Boulevard - Site Plan12.4' - PRECAST H-10 RISERS (TIP.) 2'0 4' PROVIDE WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE SYSTEM PROFILE (NOT TO SCALE) ALL SYSTEM SHALL MARKED WITHCC:MPONEMAGNETIC TAPE OR BE NOTES COMPARABLE MEANS FOR FUTURE LOCATION. NGVD 1. DATUM IS PROVIDE INSPECTION PORTS TO 2. MUNICIPAL WATER IS EXISTING WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM 11.5 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-im 4'0SCH40 PVC PIPES LEVEL 1ST 2' S. PIPE JOINTS TO BE MADE WATERTIGHT. 10" 1500 GAL H-10 14' 8.5' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE TEE SEPTIC TANK TEE 8 75' WITH 310 CMR 15.000 (TITLE V.) Qoa000000000 8.17' 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND 0 o NOT TO BE USED FOR LOT LINE STAKING OR ANY TIE ::: 0°0°0� U0. LEVEL (ACME OR EQUAL) 8.38' 8.21 0.6T OTHER PURPOSE. 7.5 �00000Qoeo�000aoo00000a WATER -TEST D'BOX FOR LEVELNESS �118. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 00 9. 32 STD. QUICK 4'S OVERALL DIMENSIONS TO OUTSICE OF UNITS: 32' X 113' 9• COMPONENTS NOT TO 8E BACKFILLED OR . 6" CRUSHED STONE OR MECHANICAL CONCEALED WITHOUT INSPECTION BY BOARD OF COMPACTION. (15.221 [21) (NO STONE PROPOSED) HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. SLOPE) (--L% % SLOPE) (-L- % SLOPE) 5.0' LEACHING 10. CONTRACTOR SHALL BE RESPONSIBLE FOR FOUNDATION- 25' SEPTIC TANK 12' D' BOX 6' CALLING DIGSAFE (1-888-344-7233) AND FACILITY VERIFIING THE LOCATION OF ALL UNDERGROUND & *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ZONING SUMMARY ZONING DISTRICT: R-25 MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BLDG. COVERAGE ALLOWED: 25% EXISTING BUILDING COVERAGE: 14.6% PROPOSED BUILDING COVERAGE: 16.9% TEST HOLE LOGS ENGINEER: DANIEL A. OJALA, PE, SE WITNESS: AMY VON HONE, RS DATE:8/19/10 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. p" 1 � 11.4' A LS 6" 1OYR 3/2 B LS 30" 1OYR 6/6 8.9' 2nd HOLE WAIVED DUE TO SPACE CONSTRAINTS C PERC M/FS 114" OBS. WATER 1.9' 1OYR 7/2 124" 10-045 1.1' EXISTING DWELLING (TO BE REMOVED) - FIRST FLOOR = 13.6' TOP FNDN = 12.4' )7 10.35 K-✓•C.25� 0.4Z- - EXIST. SHELL PARKING EXIST. BLDG. i 30 07 N o� I 11. 11.19 11.13 77N� CL �/ /180 LEMS BAY BLVD. MAP 16 PARCEL 51 N/F MARIA TROZZI, TR. t i i I v 4 EXIST. - POOL (TO " LL REMAIN) 11.45 r 1.89 I •1,.43 r PROP PARCEL A (_ PA776 16,261 t SF _ PROP. DWELL TOP FNDN. = 12.4 BENCH MARK - ON CONC. FENCE PATIO ELEVATION = 11.3 14673' PROVIDE CLEAN-OUT EXIST. BLDG. #188 BERRY AVENUE MAP 16, PARCEL 52 N/F EDGAR F. GREENEY, JR. TRS. Scale: 1 "= 20' 0 10 20 30 40 50 FEET OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. USE ADJ. WATER AT EL. 2.5' (SITE WITHIN 300' OF TIDAL 11. ANY UNSUITABLE MATERIAL ENCOUNTERED WATER BODY - TIDALLY SHALL BE REMOVED 5' BENEATH AND AROUND THE INFLUENCED G -W) PROPOSED LEACHING FACILITY. rn' 12. EXISTING LEACHING FACILITY SHALL BE PUMPED Lh17 AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP I NOT TO SCALE ASSESSORS MAP 16 PARCEL 50 LOCUS IS WITHIN FEMA FLOOD ZONE B AS SHOWN ON COMMUNITY PANEL #250015 0005D DATED 7/2/92 SITE DOES NOT LIE WITHIN APD LEWiS B'Q YB0UL SYSTEM DESIGN: -"s 0-3 _ EVAR� 17&.49 , �1,05HIGH Pr. GARBAGE DISPOSER IS NOT ALLOWED /r �? 49 DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD ry /1 USE A 440 GPD DESIGN FLOW N / DRIVEWAY EXIST. 6 -� l I PDVVD SEPTIC TANK: 440 GPD (2) = 880 7 1,.az / x 11.77 USE A 1500 GAL. H-10 SEPTIC TANK - / / � ^� N N l o� 3 � , e4 a LEACHING: 4.72 SF LF x 4' LENGTH = 18.88 SF PER STANDARD QUICK 4 INFILTRATORS IN FIELD y67 sa CONFIGURATION i / �✓ ��/. A 440 GPD/0.74 GPD/SF = 595 SF LEACHING PROP GARGE (SREQD BE r 0 REMOVED) 595 SF/18.88 SF/UNIT = 31.5 UNITS x 11 83 O 'e' THEREFORE, USE GRAVELLESS SYSTEM OF (32) ( _ TH STANDARD QUICK 4 UNITS IN FIELD I�fiJl] .32 CONFIGURATION OF 4 ROWS OF 8 UNITS 1500 GAL. ST kwA 0 0 0 0 v 07 07 i 11.4$ 1.861 EXIST. BLDG. i (SLAB) VARIANCE REQUESTED: TOP OF FOUNDATION TO BE 0.9' ABOVE HIGH PT. IN ROAD (1.1' VARIANCE REQUESTED) #23 LEWIS BAY BLVD. MAP 16, PARCEL 49 N/F JENNIFER STANLEY, TR. EXISTING SEPTIC SYSTEM TO BE REMOVED g --L1-10 DATE DANIEL A. OJALA, P.E., P.L.S. APPROVED DATE MA IBOARD OF HEALTH TITLE 5 SITE PLAN OF 15 LEWIS BAY BLVD. WEST YARMOUTH PREPARED FOR MICHAEL & JANET DURKIN AUGUST 21, 2010 I off 508-362-4541 fox 508-362-9880 downcope.com NOW47 copy enginlrerring, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 10-045DURKIN.D WG(SBO)